User manual PANASONIC CZ-64ESMC2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PANASONIC CZ-64ESMC2. We hope that this PANASONIC CZ-64ESMC2 user guide will be useful to you.

Lastmanuals help download the user guide PANASONIC CZ-64ESMC2.


Mode d'emploi PANASONIC CZ-64ESMC2
Download
Manual abstract: user guide PANASONIC CZ-64ESMC2

Detailed instructions for use are in the User's Guide.

[. . . ] 8 How to start collective operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Product Information If you have problems or questions concerning your Air Conditioner, you will need the following information. Model and serial numbers are on the nameplate on the bottom of the cabinet. Date of purchase Dealer’s address Phone number CZ-64ESMC2 Serial No. Alert Symbols The following symbols used in this manual, alert you to potentially dangerous conditions to users, service personnel or the appliance: WARNING This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death. [. . . ] Use this button to select one of the following five operations: : Used to automatically set cooling or heating operation. Only for heat pump type (temperature range: 17 to 27 °C) : Used for normal heating operation. Only for heat pump type (temperature range: 16 to 26 °C) : Used for dehumidifying without changing the room temperature. (temperature range: 18 to 30 °C) : Used for normal cooling operation. (temperature range: 18 to 30 °C) : Used to run the fan only, without heating or cooling operation. When the indication is displayed, you cannot change the mode from and or to or and . To change the mode, turn off all units once then select the mode again. : Press this button to increase the temperature setting. : Press this button to decrease the temperature setting. (HEAT) (DRY) (COOL) (FAN) NOTE H: Temperature setting buttons I: FAN SPEED button (AUTO) (HI. ) (MED. ) (LO. ) J: FLAP button : The air conditioner automatically decides the fan speed. Use this button to set the airflow direction to a specific angle. The airflow direction is displayed on the remote control unit. Operation mode Number of airflow direction settings (COOL) or (DRY) 3 (HEAT) or (FAN) 5 (AUTO) Cooling mode: 3 Heating mode: 5 • In the cool mode and dry mode, when the flaps are set in a downward position, condensation may form and drip around the vent. • Do not move the flap with your hands. EN NOTE ( ) This function is available only for models U1 and T1. Use this button to make the airflow direction sweep up and down automatically. Press this button several times until the ( ) symbol appears on the display. This function is available only for models U1, K1 and T1. 1) The flap setting can be performed only for units that have no remote controllers. 2) In the ALL or ZONE mode, no flap setting can be performed. If necessary, you should select the GROUP mode and use the FLAP button. NOTE NOTE 5 CZ-64ESMC2_all. indb 5 2011/09/07 14:37:46 Functions of buttons (Continued) K: CHECK button This button is used only when servicing the air conditioner. Do not use the CHECK button for normal operation. L: CENTRAL CTRL button Use this button to inhibit individual operation by remote controller as follows: 1: Individual ON/OFF operation is inhibited. 2: Individual ON/OFF, MODE and Temperature setting operation is inhibited. 3: Individual MODE and Temperature setting operation is inhibited. [. . . ] Set the airflow direction to a specific angle or sweep mode. By pressing , select your desired setting. Individual: Controls with the remote controller are possible. Central 1: Individual ON/OFF operation with the remote controller is inhibited. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PANASONIC CZ-64ESMC2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PANASONIC CZ-64ESMC2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag