User manual PANASONIC EWBU60W800

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PANASONIC EWBU60W800. We hope that this PANASONIC EWBU60W800 user guide will be useful to you.

Lastmanuals help download the user guide PANASONIC EWBU60W800.


Mode d'emploi PANASONIC EWBU60W800
Download
Manual abstract: user guide PANASONIC EWBU60W800

Detailed instructions for use are in the User's Guide.

[. . . ] Operating instructions Mode d'emploi Istruzioni d'uso Instrucciones de funcionamiento Gebruiksaanwijzing Instrukcja obslugi Bedienungsanleitung Upper Arm Blood Pressure Monitor Appareil de mesure de la tension artérielle au bras Misuratore di pressione sanguigna da braccio Monitor de presión arterial en brazo Bloeddrukmeter voor de bovenarm Cinieniomierz naramienny Oberarm-Blutdruckmessgerät Model No. EW-BU60 Lesen Sie diese Bedienungsanleitung vor Inbetriebnahme des Geräts vollständig durch und bewahren Sie sie sorgfältig auf. Before operating this device, please read these instructions completely and save this manual for future use. Avant d'utiliser cet appareil, veuillez lire complètement le présent mode d'emploi. Conservez-le soigneusement afin de pouvoir le consulter ultérieurement. [. . . ] Always follow the guidance of a health professional. Reading the blood pressure display Whether the systolic and diastolic blood pressure values are in the high blood pressure region or normal blood pressure region are judged based on the WHO/ISH (World Health Organization/International Society of Hypertension) blood pressure classifications, and the results are indicated by flashing the measurement value. Systolic (mmHg) High blood pressure (mild hypertension, WHO/ISH blood pressure classifications*1 140 130 moderate hypertension, severe hypertension) Borderline hypertension Normal 85 90 Diastolic (mmHg) *1 1999 World Health Organization-International Society of Hypertension Guidelines for the Management of Hypertension · Blood pressure readings will flash for approx. 5 seconds when in the high blood pressure range. Systolic blood pressure: 140 mmHg and over Diastolic blood pressure: 90 mmHg and over (Only when measurement is complete) English en18 Comparing AM and PM Average Systolic Blood Pressure Average AM and PM systolic blood pressure is displayed in order to allow you to compare readings from both time periods. Use of the AM and PM average systolic blood pressure comparison function can aid in the detection of a blood pressure pattern known as "early morning surge" in which blood pressure rises rapidly in the morning. It cannot compare correctly if the wrong date and time are set. When the unit is turned off, or when the date and time are displayed, readings can be recalled after being saved. Press the user selection button to select the user for a comparison of average AM and PM systolic blood pressures. · Each time the button is pressed, the user switches in sequence. 2 seconds. ) · The average AM and PM systolic blood pressure for the selected user will be displayed. · The average AM and PM systolic blood pressure stored in the SD memory card will be displayed if the SD memory card is inserted (for up to 1095 readings). · The average AM and PM systolic blood pressure for all the readings stored in the main unit will be displayed if the SD memory card is not inserted. 6:00 PM to 2:59 AM · The average systolic blood pressure recorded during the time periods shown above will be displayed. · When a single reading has been recorded, " " will be displayed. · Display will cycle between the average AM and PM systolic blood pressure for approximately 2 seconds, and average AM systolic blood pressure and user number for approximately 1 second. · If you forget to switch off the unit it will do so automatically after approx. 1 second. ) en19 English Storing the records from the main unit onto a SD memory card This operation is to store the readings that were stored in the blood pressure monitor to a separate SD memory card. *At this time, only the readings that were stored on the SD memory card in the past will be stored to the SD memory card. To store readings that were not previously stored in the SD memory card, insert the SD memory card into the main unit, take a measurement once, and the reading will also be stored into the SD memory card when it is stored to the main unit. Press the button for 3 seconds or longer while the unit is turned off. · The "Sd inP" will be lit on the display, and the user number "no. 1" will flash. · Press the Off/On Start button to cancel. 2. [. . . ] The customer or the user of the model EW-BU60 should insure that it is used in such an environment Immunity IEC 60601 Compliance Electromagnetic test test level level environment - guidance Electrostatic ±6 kV contact ±6 kV contact Floors should be wood, concrete or discharge (ESD) ±8 kV air ±8 kV air ceramic tile. If floors are covered with IEC 61000-4-2 synthetic material, the relative humidity should be at least 30 %. Electrical fast ±2 kV for power ±2 kV for power Mains power quality should be that transient/burst supply lines supply lines of a typical commercial or hospital IEC 61000-4-4 ±1 kV for ±1 kV for environment. input/output lines input/output lines Surge ±1 kV for differential ±1 kV for differential Mains power quality should be that IEC 61000-4-5 mode mode of a typical commercial or hospital ±2 kV common mode ±2 kV common mode environment. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PANASONIC EWBU60W800

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PANASONIC EWBU60W800 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag