Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PANASONIC S100FM3HPQ. We hope that this PANASONIC S100FM3HPQ user guide will be useful to you.
Lastmanuals help download the user guide PANASONIC S100FM3HPQ.
Detailed instructions for use are in the User's Guide.
[. . . ] Do not install or operate the unit in rooms mentioned below. - Places with mineral oil, or filled with oil vapour or spray like in kitchens. ) - Where the air contains high levels of salt such as air near the ocean and where voltage fluctuates a lot (e. When selecting the installation site, use the supplied paper pattern for installation. [. . . ] - Keep pipe size equal to or greater than that of the connecting pipe (vinyl pipe of 25 mm nominal diameter and 32 mm outer diameter). When connecting the flare nut, coat the flare both inside and outside with ether oil or ester oil and initially tighten by hand 3 or 4 turns before tightening firmly. Coat here with ether oil or ester oil If the drain hose cannot be sufficiently set on a slope, fit the hose with drain raising piping (field supply). 1 2 3 4 Ceiling slab Hanging bar Adjustable range Drain hose (supplied with the unit) Metal clamp (supplied with the unit) Drain raising pipe (field supply) 1 2 3 4 5 Liquid pipe Gas pipe Insulation for fitting of liquid line (supplied with the unit) Insulation for fitting of gas line (supplied with the unit) Clamps (use 2 clamps per insulation) Connect the drain hose to the drain pipe on the indoor unit, and tighten it with the metal clamp. To ensure a downward slope of 1:100, install hanging bars every 1 to 1. After piping work is finished, check if drainage flows smoothly. The drain outlet is only used to discharge water if the drain pump is not used or before maintenance. All field supplied parts and materials and electric works must conform to local codes. Follow the "Wiring diagram" attached to the switch box cover to wire the outdoor unit, indoor units and the remote controller. A circuit breaker capable of shutting down power supply to the entire system must be installed. this system consists of multiple indoor units. Mark each indoor unit as unit A, unit B. , and be sure the terminal board wiring to the outdoor unit and HR box are properly matched. If wiring and piping between the outdoor unit and an indoor unit are mismatched, the system may cause a malfunction. Do not wiggle the plug up and down Pushing in the plug Set the plug and push it by using a Philips screwdriver When electric wiring work is finished Check drainage flow during COOL running, explained in "Test operation" on page 7. When electric wiring work is not finished Remove the switch box cover and connect the single-phase power supply and the remote controller to the terminals. (Refer to "Electric wiring work" on page 5 for switch box attachment/detachment. ) (Refer to figure 11a and figure 11b) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Switch box cover Power supply wiring port Transmission wiring port Wiring diagram Switch box Plastic clamp Remote controller wiring Terminal board for unit transmission wiring Power supply wiring Indoor PC board Power supply terminal board Earth screw Transmission wiring between units Adaptor for PC board Until selecting fan operation Allowable length of transmission wiring between indoor and outdoor units, and between the indoor unit and the remote controller is as follows: To go back to the first mode. According to the systems static pressure requirement, reposition the adaptors of the PC board inside the switch box as shown in the figure. From the outside of the unit Remove the switch box cover as shown in figure 11b, and make the connections. From the inside of the unit Remove the small bottom plate and the interchangeable plate (in case of rear suction) or the air filter holding plate (in case of bottom suction). Lower the switch box as shown in figure 11c. [. . . ] Clean the air filter and outside panels. After cleaning the air filter, make sure to attach it. The control panel display lights when the power is turned on. To protect the unit, turn on the main power switch at least 6 hours before operation. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE PANASONIC S100FM3HPQ
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PANASONIC S100FM3HPQ will begin.