[. . . ] Using of refrigerant other than the specified type may cause product damage, burst and injury etc. * This air conditioner has no ventilator for intaking fresh air from outdoors. You must open doors or windows frequently when you use gas or oil heating appliances in the same room, which consume a lot of oxygen from the air. Otherwise there is a risk of suffocation in an extreme case. [. . . ] Indb 3
2014/09/18 9:31:39
Precautions for Use
Installation
This air conditioner must be installed properly by qualified installation technicians in accordance with the Installation Instructions provided with the unit. Before installation, check that the voltage of the electric sup ply in your home or office is the same as the voltage shown on the nameplate. Operation Condition
Use this air conditioner under the following temperature range. Outdoor Unit
2WAY (ME1 type) Cooling Heating 3WAY (MF2 type) Cooling Heating Cooling & Heating
Indoor temperature range
Outdoor temperature range
WARNING
Avoid the following locations for installation. Locations where excessively high heat-generating ob jects are placed. 14°C 25°C (*WBT) -10°C 46°C (*DBT) 16°C 30°C (*DBT) -25°C 15°C (*WBT) 14°C 25°C (*WBT) -10°C 46°C (*DBT) 15°C 30°C (*DBT) -20°C 18°C (*WBT) ― -10°C 24°C (*DBT)
Attention:
Avoid installing the outdoor unit where salty sea water can splash directly onto it or in sulphurous air near a spa. (To protect the air conditioner from heavy corrosion)
*DBT: Dry bulb temperature *WBT: Wet bulb temperature
When used in FRESH AIR INTAKE MODE
Outdoor Unit
2WAY (ME1 type) Cooling Heating 3WAY (MF2 type) Cooling Heating Cooling & Heating
ON
Indoor temperature range
14°C 16°C 14°C 15°C
Outdoor temperature range
46°C (*DBT) 16°C (*DBT) 46°C (*DBT) 16°C (*DBT) 24°C (*DBT)
Wiring
All wiring must conform to the local electrical codes. (Consult your dealer or a qualified electrician for details. ) Each unit must be properly grounded with a ground (or earth) wire or through the supply wiring. Wiring must be done by a qualified electrician. ς
25°C (*WBT) 22°C 30°C (*DBT) -5°C
25°C (*WBT) 22°C 30°C (*DBT) ― -5°C -5°C
Operation Preparation
Turn the power mains on 5 hours before the start of operation. 7) The fan function of this unit supplies the outdoor air to the indoor space. ς Group Control
Group control function is suitable for operating the multiple air conditioners in a large single room. Operation of all indoor units in the same mode except for airflow direction. Use the indoor unit's temperature sensor. Outdoor unit
Remote controller Signal line
Operation Mechanism
Heating performance
Since this air conditioner utilizes outside air for heating, its heating performance deteriorates as outside temperature decreases. (Due to heat pump system) →In that case, use another heating appliance. This appliance may start defrosting operation to melt frost formed in the outdoor unit. 1Defrosting starts: The indoor unit fan stops (or the speed becomes extremely slow). → “ ” (STANDBY) appears. ς ‘‘DRY’’ operation
Defrosting
Once the room temperature reaches the level that was set, the outdoor unit repeats the cycle of turning on and off automatically. When the outdoor unit is turned off, the indoor unit fan will stop, too. [. . . ] 4)
If your air conditioner does not work properly even after checking each item of “Before Requesting Services” and “Troubleshooting”
Stop the operation immediately and turn the power off. Then contact your dealer and report the serial number and symptom. ς You also report if the inspection mark and the letters E, F, H, L, P in combination with numbers appear on the LCD of the remote controller. Never repair the air conditioner by yourself since it is very dangerous for you to do so. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE PANASONIC S280ME2E5
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.