Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PANASONIC S-36MY2E5A. We hope that this PANASONIC S-36MY2E5A user guide will be useful to you.
Lastmanuals help download the user guide PANASONIC S-36MY2E5A.
Detailed instructions for use are in the User's Guide.
[. . . ] Indoor Units Wall Mounted (K2 type) S-15MK2E5A S-22MK2E5A S-28MK2E5A S-36MK2E5A Indoor Units 4-Way Cassette 60x60 (Y2 type) S-15MY2E5A S-22MY2E5A S-28MY2E5A S-36MY2E5A S-45MY2E5A S-56MY2E5A
Operating Instructions Air Conditioner
Outdoor Units mini (LE1 type) U-4LE1E5 U-5LE1E5 U-6LE1E5 U-4LE1E8 U-5LE1E8 U-6LE1E8 2WAY (ME1 type) U-8ME1E81 U-10ME1E81 U-12ME1E81 U-14ME1E81 U-16ME1E81 U-18ME1E81 U-20ME1E81 3WAY (MF2 type) U-8MF2E8 U-10MF2E8 U-12MF2E8 U-14MF2E8 U-16MF2E8
2 ~ 15 ENGLISH Before operating the unit, read these operating instructions thoroughly and keep them for future reference. 172
PRODUCT INFORMATION
If you have problems or questions concerning your Air Conditioner, you will need the following information. Model and serial numbers are on the nameplate on the bottom of the cabinet. _______________________
Date of purchase ______________________________________________________________ Dealer’s address ______________________________________________________________ Phone number________________________________________________________________
SAFETY PRECAUTIONS
The following symbols used in this manual, alert you to potentially dangerous conditions to users, service personnel or the appliance: This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death. [. . . ] Display shows the indoor unit number under group control. Set the airflow direction for the indoor unit that is shown on the display. Each time UNIT is pressed, the indicator changes in the order shown below. When nothing is displayed, you can make the setting for all indoor units in one operation. The unit number is displayed as Outdoor Unit Number–Indoor Unit Number. It varies depending on the number of units under group control. 2–4
• • •
One outdoor unit and eight indoor units
No display Unit No. Fm Page 12 Wednesday, December 11, 2013 9:41 AM
SPECIAL REMARKS
‘‘DRY’’ Operation
How it works • • • • Once the room temperature reaches the level that was set, the unit repeats the cycle of turning on and off automatically. In order to prevent the humidity in the room from rising again, the indoor fan also turns off when the unit stops operating. The fan speed is set to ‘‘LO. ’’ automatically , and cannot be adjusted. ‘DRY’’ operation is not possible if the outdoor temperature is 15 °C or less. Heating Operation
Heating performance • Because this appliance heats a room by utilizing the heat of the outside air (heat pump system), the heating efficiency will fall off when the outdoor temperature is very low. If sufficient heat cannot be obtained with this heat pump, use another heating appliance in conjunction with this unit. When the outdoor temperature is low, frost or ice may form on the outdoor heat exchanger coil, reducing the heating performance. when this happens , a microcomputer-controlled defrosting system operates. At the same time, the fan on the indoor unit stops (or runs at very low speed in some cases) and the ‘‘STANDBY’’ indicator appears on the display until defrosting is completed. Heating operation then restarts after several minutes. (This interval will vary slightly depending upon the outdoor temperature and the way in which frost forms. ) For several minutes after the start of heating operation, the indoor fan will not start running (or it will run at very low speed in some cases) until the indoor heat exchanger coil has warmed up sufficiently. This is because a cold draft prevention system is operating. During this period, the ‘‘ ’’ (standby) indicator remains displayed. [. . . ] Lead (Pb) – not over 0, 1wt % or 1000wt ppm; Cadmium (Cd) – not over 0, 01wt % or 100wt ppm; Mercury (Hg) – not over 0, 1wt % or 1000wt ppm; Hexavalent chromium (Cr6+) – not over 0, 1wt % or 1000wt ppm; Polybrominated biphenyls (PBBs) – not over 0, 1wt % or 1000wt ppm; Polybrominated diphenyl ethers (PBDEs) – not over 0, 1wt % or 1000wt ppm. Untuk mencegah kemungkinan bahaya akibat kegagalan isolasi, unit harus diarde Jangan bersihkan sendiri bagian dalam unit indoor dan outdoor. Jangan masukkan jari tangan Anda atau benda lain ke unit dalam atau unit luar pendingin ruangan, suku cadang yang berputar bisa mengakibatkan cedera. Fm Page 167 Wednesday, December 11, 2013 10:00 AM
MENGATUR ARAH ALIRAN UDARA UNTUK BEBERAPA UNIT INDOOR MENGGUNAKAN SATU REMOTE CONTROL (BERKABEL)
• Jika beberapa unit indoor tersambung ke remote control, arah aliran udara dapat diatur untuk setiap unit indoor dengan memilih unit indoor terkait (lihat pengoperasian di bawah ini). [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE PANASONIC S-36MY2E5A
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PANASONIC S-36MY2E5A will begin.