Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PANASONIC SL-Q210. We hope that this PANASONIC SL-Q210 user guide will be useful to you.
Lastmanuals help download the user guide PANASONIC SL-Q210.
Detailed instructions for use are in the User's Guide.
[. . . ] Use numbers indicated in parentheses when asking for replacements parts. (Only for U. S. A. ) To order accessories contact 1-800-332-5368 or the website (http://www. pasc. panasonic. com). SL-1210M5G(SFTE172-01Z1) SL-Q210(SFTE172-02Z) Balance weight . . . . . . . SL-1210M5G(SFPWG17201BK) SL-Q210(RYQ0156-N)
Table of contents
Supplied accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
3
RQT7021
Features
A masterpiece amongst turntables with a worldwide reputation. Highly accurate turntable speed maintained continuously with a quartz pitch control.
·The [±16/±8] button can control a wide range between 8 % and +8 % and 16 % and +16 %. The [±16/±8] indicator LED illuminates in the dark. ·The pitch can be varied throughout the range maintaining perfect accuracy. ·Pitch can be instantly reset to the rated speed (33 1/3 or 45 r/min) with the reset button. ·The pitch control slider can be easily replaced.
Controls
The direct drive produces high torque.
·Wow and flutter below 0. 01 %. Starting torque of 1. 5 kg-cm enabling the turntable to reach 33 1/3 r/min in 0. 7 seconds. ·Smooth stops are achieved with a fully electronic braking system. The braking speed can be adjusted with the brake speed control knob.
Tone arm with gimbal suspension
·Using the balance weight control measurement units on the tone arm, you can quickly change stylus pressure settings to the appropriate pressure. ·Stylus skipping can be reduced using horizontal weight control for scratch play. Turn the balance weight until the arm is approximately horizontal.
Take care at this time not to allow the stylus to touch the unit. Balanced Too far forward Too far back Arm clamp
4
Adjust stylus pressure
Turn the balance weight to adjust to the appropriate pressure for the cartridge you are using.
See the cartridge's instructions for recommended stylus pressure. The stylus pressure control will turn at the same time. Stop when the center line points to the required pressure.
Turn balance weight Arm clamp Arm rest Cue lever Center line
Anti-skating control
For your reference
Use the stylus weight (included) to increase stylus pressure by 4 grams. Stylus weight
6
RQT7021
Head shell
Preparatory adjustments
Using the balance weight control
Make note of the balance weight setting for your stylus cartridge, you can quickly change the stylus pressure without having to readjust the horizontal balance of the arm each time you remove and re-attach the stylus cartridge. Attach the cartridge to the tone arm you are using. Turn the balance weight control to the setting you previously used to balance the weight including cartridge. Turn the stylus pressure control dial to the setting you previously used to balance the weight including cartridge.
Tone arm height
1. Release the arm lock.
Released
1 3
Locked
2. Adjust the arm height.
·Adjust the ring using the chart below as reference so the arm height matches the indicated height of the cartridge. Measurements are marked on the arm height control ring in 0. 5 millimeter intervals.
Balance weight measurement units
Index line Arm height control ring Cartridge height (H) in millimeters Height control position 0 1 2 3 4 5 6
Anti-skating
Adjust the dial to the same value as the stylus pressure control when playing normal music.
For scratch play Adjust the control to reduce skipping.
17 18 19 20 21 22 23
·If you do not know the height of your cartridge, rest the stylus on a record and adjust the height control until the tone arm and record are parallel. [. . . ] Safety check--After repairs or service, ask the servicer to perform safety checks to confirm that the unit is in proper working condition.
Thoroughly clean dust off the stylus and record.
·Use a soft brush to clean the stylus. ·Use a good quality record cleaner to keep your records clean.
Head shell terminals
Wipe the head shell terminals occasionally.
Use a soft cloth. Turn the amplifier off before fitting or removing the head shell. ·Damage to your speakers can occur if the head shell is moved while the volume is turned up. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE PANASONIC SL-Q210
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PANASONIC SL-Q210 will begin.