User manual PANASONIC U-71PE1E8A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PANASONIC U-71PE1E8A. We hope that this PANASONIC U-71PE1E8A user guide will be useful to you.

Lastmanuals help download the user guide PANASONIC U-71PE1E8A.


Mode d'emploi PANASONIC U-71PE1E8A
Download
Manual abstract: user guide PANASONIC U-71PE1E8A

Detailed instructions for use are in the User's Guide.

[. . . ] INDOOR UNIT ENGLISH S-60PK1E5A S-71PK1E5A S-100PK1E5A Wall Mounted (K1 type) S-36PK1E5A S-45PK1E5A S-50PK1E5A OUTDOOR UNIT Before operating the unit, read these operating instructions thoroughly and keep them for future reference. Indb 1 2014/03/05 10:34:09 Thank you for purchasing this Panasonic product. Using of refrigerant other than the specified type may cause product damage, burst and injury etc. This air conditioner has no ventilator for intaking fresh air from outdoors. [. . . ] Attention: Avoid installing the outdoor unit where salty sea water can splash directly onto it or in sulphurous air near a spa. (To protect the air conditioner from heavy corrosion) Wiring All wiring must conform to the local electrical codes. (Consult your dealer or a qualified electrician for details. ) Each unit must be properly grounded with a ground (or earth) wire or through the supply wiring. Wiring must be done by a qualified electrician. Operation Preparation Turn the power mains on 5 hours before the start of operation. (For warm-up) Leave the power mains ON for continuous use. ON NOTE Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the air conditioner from the main power supply when not in use for a long time. For business users in the European Union If you wish to discard electrical and electronic equipment, please contact your dealer or supplier for further information. [Information on Disposal in other Countries outside the European Union] These symbols are only valid in the European Union. If you wish to discard these items, please contact your local authorities or dealer and ask for the correct method of disposal. Note for the battery symbol (bottom two symbol examples): This symbol might be used in combination with a chemical symbol. In this case it complies with the requirement set by the Directive for the chemical involved. CZ-RTC3 For all indoor units Read the operating instructions included with the Remote Controller. Operation Mechanism Heating performance Since this air conditioner utilizes outside air for heating, its heating performance deteriorates as outside temperature decreases. (Due to heat pump system) →In that case, use another heating appliance. This appliance may start defrosting operation to melt frost formed in the outdoor unit. 1Defrosting starts: The indoor unit fan stops (or the speed becomes extremely slow). →” ” (STANDBY) appears. €‘DRY’’ operation Defrosting Once the room temperature reaches the level that was set, the outdoor unit repeats the cycle of turning on and off automatically. When the outdoor unit is turned off, the indoor unit fan will stop, too. (To prevent the humidity in the room from rising again) When the room temperature is more likely to reach the level that was set, the fan speed is set to ‘‘breeze’’ (light wind) automatically. [. . . ] Cause / Action • Sound of refrigerant liquid flowing inside unit • Sound of drainage water through drain pipe Sound due to temperature changes of parts • Indoor odor components, cigarette odor and cosmetic odor accumulated in the air conditioner and its air is discharged. € If the air conditioner has been installed at places such as restaurants where large amounts of oil mist exist, cleaning is necessary because the unit inside (heat exchanger) is dirty. E NGLISH Dewdrops accumulate near the air outlet during cooling operation. The fan is rotating for a while even though operation stops. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PANASONIC U-71PE1E8A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PANASONIC U-71PE1E8A will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag