Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PANASONIC WH-SDC03E3E5. We hope that this PANASONIC WH-SDC03E3E5 user guide will be useful to you.
Lastmanuals help download the user guide PANASONIC WH-SDC03E3E5.
You may also download the following manuals related to this product:
PANASONIC WH-SDC03E3E5 (2981 ko)
Manual abstract: user guide PANASONIC WH-SDC03E3E5
Detailed instructions for use are in the User's Guide.
[. . . ] Indoor Unit Outdoor Unit
WH-SDC03E3E5 WH-SDC05E3E5
WH-UD03EE5 WH-UD05EE5
ENGLISH Before operating the unit, read these operating instructions thoroughly and keep them for future reference. Before operating the unit, make sure the installation has been carried out correctly by authorized dealer correctly and precisely following the installation instructions given. 2 ~ 11
12 ~ 21
22 ~ 31
32 ~ 41
42 ~ 51
52 ~ 61
62 ~ 71
72 ~ 81
82 ~91
F568783
SAFETY PRECAUTIONS
Thank you for purchasing Panasonic Product TABLE OF CONTENTS SAFETY PRECAUTIONS 2~3 CONTROL PANEL 4~8 INDOOR UNIT 9 TROUBLESHOOTING 10 INFORMATION 11 NOTE The illustrations in this manual are for explanation purposes only and may differ from the actual unit. They are subjected to change without notice for future improvement. [. . . ] ¢ The control panel can be used for multiple installations. Some functions may not be applicable to your unit. ¢ Ensure the operation LED is in OFF condition before setting. Press and simultaneously for 5 seconds to enter special setting mode. Indoor Backup Heater Capacity Selection (3kW / 6kW / 9kW) To reduce the heater power whenever unnecessary. Solar Priority (YES / NO) To choose the solar use for water tank heat up. Cooling Priority (YES / NO) To choose the room cooling as priority during COOL + TANK mode. if select âCooling priorityâ is âYESâ , Set 8 ~ 9 are irrelevant to COOL + TANK mode. Heating Priority (YES / NO) To choose the room heating as priority during HEAT + TANK mode. note: If select âHeating priorityâ is âYESâ , Set 8 ~ 9 are irrelevant to HEAT + TANK mode. Cooling/Heating operation Interval Set To set timer for Cool mode or Heat mode during COOL + TANK mode or HEAT + TANK mode (0. If both âHeating priorityâ and âCooling priorityâ are âYESâ, Set 8 ~9 are skipped. Tank Heat-up Interval Set To set timer for Tank during COOL + TANK mode or HEAT + TANK mode (5minutes ~ 1hour 35minutes). booster Heater Function (YES / NO) To activate or deactivate tank booster heater function Note: If select âBooster heater functionâ is âNOâ , Set 11 is skipped. Booster Heater Delay Timer Set To set delay timer for booster heater to ON if water tank temperature is not reached (20minutes ~ 1hour 35minutes). ¢ Do not use the system during sterilization to prevent scalding or overheat during shower. ¢ The sterilization function ï¬eld settings must be conï¬gured by the authorized dealer according to local laws and regulation. Sterilization Day & Time Set To set timer for sterilization (only once a week, will operate even in standby condition). sterilization Temperature Set To set temperature for sterilization function (40°C ~ 75°C). Sterilization Continue Time To set timer to maintain heating temperature in order to complete the sterilization function (5minutes ~ 1hour). BASIC OPERATION
OFF / ON
TO TURN ON OR OFF THE UNIT
⢠When unit is ON, operation LED is lit and the actual temperature for water outlet and outdoor ambient are shown on the control panel display. MODE
TO SELECT OPERATION MODE
HEAT COOL HEAT +TANK TANK COOL + TANK
⢠HEAT MODE - To turn ON or OFF the panel/ï¬oor heating operation. [. . . ] When water outlet set temperature is low, it may be difï¬cult to get warm. Due to the nature of the heatpump system, it may take some time to heat-up the water if the unit is operated from cold-start. The turn ON of backup heater is a protection to the indoor unitâs heat exchanger. Backup heater turn ON automatically when it is not enabled. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE PANASONIC WH-SDC03E3E5
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PANASONIC WH-SDC03E3E5 will begin.