[. . . ] Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. FCC Caution: To assure continued compliance, (example use only shielded interface cables when connecting to computer or peripheral devices). Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.
SA 1965
The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
The serial number of this product may be found on the bottom of the unit. [. . . ] Pin #9 supplies a tally output while CH 4 is selected.
q Internal Setting
The following functions can be set with internal connectors and switches when you need to change default settings marked with *. Refer to the Service Manual for internal settings. · ALARM/REMOTE terminal definition (In*/Out) . . . . . . . . . . . . . . . CN702, CN703 · Alarm reset signal input (0V-5V*/O. C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SW704 · Setup menu to CAM OUT (ON*/OFF) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SW702
q RS-485 DATA Port Connection (PS · Data)
Data ports are connected with RS-485 cables among devices using PS · Data protocol as follows. · Internal Diagram
RX (B) RX (A) TX (B) TX (A)
6 1
No. 1 2 3 4 5 6
Name GND RX(B) RX(A) TX(B) TX(A) GND
Data Flow WJ-MX30 WV-CU360C WJ-MX30 WV-CU360C WJ-MX30 WV-CU360C WJ-MX30 WV-CU360C
No. 1 2 3 4 5 6 6
Controller end
1
17
· Basic Connection
Data Multiplex Unit WJ-MX30
System Controller WV-CU360C
DATA
DATA
Termination: ON
Termination: ON
RS-485 Cable
· Daisy Connection
Video Multiplexer WJ-FS309 (WJ-FS316) Data Multiplex Unit WJ-MX30 System Controller WV-CU360C
DATA
DATA
DATA
Termination: ON
Termination: OFF
Branch Cable
Termination: ON
RS-485 Cable
RS-485 Cable
q RS-485 Terminal Connection (Camera Communication)
These terminals are connected with system devices using the Camera Communication Protocol in 4-line full duplex or 2-line half duplex mode specified with the DIP switch setting. Notes: · Use a data grade, shielded and twisted cable suited to RS-485. The maximum allowable cable length is 4 000 ft (1 200m). ALARM ALARM OUTPUT ALARM DATA COMP/VD2/DATA CAMERA IN COMP VD2 DATA VS/VD INPUT DAISY MODE TERMINAL
20
s Setup Menus for PS · Data
q Communication setup (PS · Data)
Communication parameters for a PS · Data protocol system are set in this menu. Hold down the SETUP button for 2 seconds to open the setup menu.
DATA BIT 1. Move the cursor to DATA BIT, then specify a bit length with the [] or [+] button. Available bit length: 7, 8
WJ-MX30 SETUP MENUX. XX COMMUNICATION SYSTEM
PARITY 1. Move the cursor to PARITY CHECK, then specify a check mode with the [] or [+] button. Available check modes: NONE, EVEN, ODD
STOP BIT 1. Move the cursor to STOP BIT, then specify a bit length with the [] or [+] button. , then press
COMMUNICATION UNIT ADDRESS BAUD RATE DATA BIT PARITY CHECK STOP BIT WAIT TIME 1 9600 8 NONE 1 OFF
WAIT TIME The unit will retransmit data when there is no response during the specified wait time. Move the cursor to WAIT TIME, then specify a time with the [] or [+] button. The default setting is OFF for not resending. Available wait times (ms): OFF, 100, 200, 400, 1 000 2. [. . . ] · Site alarm A camera detects motion change in video (VMD, Video Motion Detection).
s Camera Selection
q Front Panel Operation
· You need to remove the front cover loosening the screw with a screw driver before starting operation. · Press a camera number button.
1
2
3
4
q Processing
· The spot image changes to that of the alarm activated camera when ALARM MODE is set to ON in the setup. · The camera moves to the preset position. · "ALARM ***" blinks overlaid on the spot image when ALARM DISPLAY is set to ON.
The selected camera picture is displayed on the monitor connected to the SPOT OUT terminal on the rear of the unit.
ALARM 001
· The alarm indicator blinks.
q Alarm Output q WV-CU360C Operation
· Enter a camera number with numeric buttons, then press the CAM/SET button. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE PANASONIC WJ-MX30
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.