User manual PANASONIC WJ-SX650P

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PANASONIC WJ-SX650P. We hope that this PANASONIC WJ-SX650P user guide will be useful to you.

Lastmanuals help download the user guide PANASONIC WJ-SX650P.


Mode d'emploi PANASONIC WJ-SX650P
Download
Manual abstract: user guide PANASONIC WJ-SX650P

Detailed instructions for use are in the User's Guide.

[. . . ] Matrix Switcher Operating Instructions Model Nos. WJ-SX650 Series OPE RAT E OP IF CO ERAT LLIN E LED G FA W N M ILL BLIN ALFU K NCTI ONS Matrix Switc her W J-SX 650 Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN For Canada This Class A digital apparatus complies with Canadian ICES-003. For U. S. A CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. SA 1965 The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. [. . . ] 100 ms, 200 ms, 400 ms, 1 sec: Period until alarm notification is retried 0 to 16: Total recorder number Note: When camera input channels to supply video input signals from recorders are set to "RS485" in "System" ­ "RS485 Camera", the RS-485 settings are automatically canceled. ON, OFF, AUTO, _: B/W setting PATROL1(S) to PATROL4(S) , _: Scene [PATROL(S)] setting ON: Perform OFF: Not perform Note: Depending on the specifications of recorders, recording may be stopped for several seconds at the timing of auto time adjustment. ON: Perform OFF: Not to perform Note: To perform auto time adjustment, check the specifications of connected device before the setting. OFF: Not notify 1, 5, 10, 30 or 60 sec Select the interval to notify the system status. (Recommended: 5 or more sec) 47 48 49 50 51 52 53 54 55 56 57 58 60 61 62 63 64 44 Factory Default Settings In the factory default, each setting item has been set as follows. Items attached with "*" can also be set in SETUP MENU. G Display "Display" Date Format: Mmm/DD/YYYY Time Format: 12-h Language: English* "DST/Summer Time" DST/Summer Time: ON* Start Time: 02:00 AM DST/Summer Time Table: The first Sunday in April to the last Sunday in October I Factory Default Settings of WJSX650 Series Administrator Console G System "Recorder" Recorder Output: External Monitor Recorder 1 2 · · 16 "DATA Port" DATA 1 2 3 4 5 6 7 8 Type TMNL1* TMNL2* HDR1* HDR2* TMNL5* TMNL6* HDR3* HDR4* Communication Status 9 600 bps 9 600 bps 9 600 bps 9 600 bps 9 600 bps 9 600 bps 9 600 bps 9 600 bps Control ON* ON* · · ON* LCN 257 258 · · 272 LCN Setting 1 to 16 17 to 32 · · 241 to 256 G Camera "Camera Title" CAM 1 · · 256 Custom Chars: A to Z, a to f "Camera Position" CAM-P 1 to 64 65 to 128 129 to 192 193 to 256 LCN LCN 1 (Preset 1 to 64) LCN 2 (Preset 1 to 64) LCN 3 (Preset 1 to 64) LCN 4 (Preset 1 to 64) Camera Title 1 · · 256 "Logical Camera Number" CAM 1 · · 256 "VD2/DATA/Cable Comp. " CAM 1 to 256 VD2 ON* DATA ON* Cable S* LCN 1 · · 256 G Sequence "Tour Sequence" Tour Sequence 1: Images of LCN 1 to 32 are sequentially switched for two seconds. Tour Sequence 2: Images of LCN 33 to 64 are sequentially switched for two seconds. Tour Sequence 3: Images of LCN 65 to 96 are sequentially switched for two seconds. Tour Sequence 4: Images of LCN 97 to 128 are sequentially switched for two seconds. Tour Sequence 5: Images of LCN 129 to 160 are sequentially switched for two seconds. Tour Sequence 6: Images of LCN 161 to 192 are sequentially switched for two seconds. Tour Sequence 7: Images of LCN 193 to 224 are sequentially switched for two seconds. Tour Sequence 8: Images of LCN 225 to 256 are sequentially switched for two seconds. Tour Sequence 9 to 32: No settings "RS485 Camera" No setting RS485 1 to 32 Commuinication Status 19 200 bps 45 "Group Sequence" Group Sequence 1: 4 cameras among LCN 1 to 64 are sequentially switched for 2 seconds on Monitor 1 to 4. Group Sequence 2: 4 cameras among LCN 65 to 128 are sequentially switched for 2 seconds on Monitor 5 to 8. Group Sequence 3: 8 cameras among LCN129 to 256 are sequentially switched for 2 seconds on Monitor 9 to 16. Group Sequence 4 to 8: No settings Group Sequence 9: Spot image of LCN 1 to 16 are displayed on Monitor 1 to 16. Group Sequence 10 to 32: No settings "Alarm Event" Terminal Alarm 1 to 256: SPOT, LCN 1 to 256, Monitor 1 Camera Alarm 1 to 256: No settings Recorder Alarm 1 to 256: No settings Serial Alarm 1 to 1024: No settings Video Loss 1 to 256: Monitor 2 (No events) "Monitor Display Mode" Monitor 1 to 16 17 to 24 25 to 32 "Alarm Schedule" No settings Display Mode Spot Tour Sequence Group Sequence G Schedule "Timer Event" No settings "Camera Event" No settings G Operator "Operator" Note: Refer to p. PS·Data: User ID: 650 HDR Operation Using the Web Browser: Priority: 1 G Alarm "Alarm Mode" Alarm Mode: Sequence* (Dwell Time: 2 sec*) Auto Reset: 30 sec* Terminal Alarm: ON (All alarms are N. O. )* Camera Alarm: OFF* Recorder Alarm: OFF* Serial Alarm: ON* Video Loss: OFF* "Level Table" Item System Setup OSD Control Alarm History Display System Status Display Alarm Suspension Alarms All Reset Alarm ACK, Alarm Individual/ Monitor Reset Start Tour Sequence Start Group Sequence Monitor Lock Camera Setup Preset Position Registration All Cameras Control Camera Control Camera Selection Recorder Setup Recorder Control Level 1 Enabled (Checked) Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Level 2 Disabled (Not checked) Enabled Enabled Disabled Disabled Enabled Enabled Enabled Enabled Enabled Disabled Enabled Enabled Enabled Enabled Disabled Enabled Level 3 Disabled Disabled Disabled Disabled Disabled Disabled Enabled Enabled Enabled Disabled Disabled Disabled Disabled Enabled Enabled Disabled Enabled Level 4 Disabled Disabled Disabled Disabled Disabled Disabled Disabled Enabled Enabled Disabled Disabled Disabled Disabled Disabled Enabled Disabled Disabled Level 5 Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Enabled Disabled Disabled 46 G Controller "Monitor Access" DATA 1 to 8 Monitor All the ports are enabled. (Checked) "Auto Login/Logout" Auto Login: All the ports are enabled. (Checked) (User ID: 650) Auto Logout: All the ports are unabled. (Not Checked) "Key Assignment" (Available for WV-CU950/650) DATA 1 to 8 A B TOP Function Iris Reset Auto Focus Auto Focus G Communication "Serial Command" Alarm Notification: OFF System Status Notification: OFF Alarm Output: OFF "PS. Data" Unit Address: 1 <Communication Status> Alarm Data: 1 sec Retry Timing: OFF <Auto Time Adjustment> Recorder (HDR port): OFF Whole PS. Data System (PSD port): OFF Adjustment time: 02:00 PM I Factory Default Settings of SETUP MENU "SYSTEM" Menu Communication speed of SERIAL port: 38 400 bps 47 Setup Menu (OSD) This chapter explains about SETUP MENU (On-screen Display setup menu) of this unit. G Top Menu When SETUP MENU is opened, the top menu is displayed on the monitor. I Basic Operations To control SETUP MENU, display SETUP MENU on a monitor. WJ-SX650 SETUP MENU 100 TIME&DATEO 300 ALARMO 400 RECORDERO 500 SYSTEMO 800 INFORMATIONO 900 LANGUAGE ENGLISH G WV-CU950/650 1. [. . . ] You cannot change the monitor display modes of monitors associated with alarm events. Delete alarm event settings for which the monitor is assigned. 66 Cannot click a checkbox to activate Auto Login and Auto Logout in "Controller" ­ "Auto Login/Auto Logout". · Check if the DATA port is set to PSD or HDR in "System" ­ "DATA Port". You cannot set auto login and auto logout for DATA ports set to PSD or HDR. Set the DATA port to TMNL. ­ 93 I Power Cord, Connectors, and Power Plug Check the power cord, connectors, and power plug regularly. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PANASONIC WJ-SX650P

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PANASONIC WJ-SX650P will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag