User manual PEAVEY ICA 400V

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PEAVEY ICA 400V. We hope that this PEAVEY ICA 400V user guide will be useful to you.

Lastmanuals help download the user guide PEAVEY ICA 400V.


Mode d'emploi PEAVEY ICA 400V
Download
Manual abstract: user guide PEAVEY ICA 400V

Detailed instructions for use are in the User's Guide.

[. . . ] Intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. CAUTION: To reduce the risk of electric shock, do not remove cover. WARNING: To prevent electrical shock or fire hazard, do not expose this appliance to rain or moisture. Before using this appliance, read the operating guide for further warnings. [. . . ] ): 1, 100 @ 1/3 power 4 ohms, 850 @ 1/3 power 8 ohms, 635 @ 1/8 power 4 ohms, 540 @ 1/8 power 8 ohms Cooling 120 mm DC fan, off until heatsinks reach 45° C, then variable speed Controls: 2 rear panel attenuators, sequential turn-on / off Indicator LEDs: 2 Clip, 2 Signal, 2 LFC, 1 Protect, 1 Power Protection: Temp. , DC, turn-on bursts, subsonic, incorrect load or short Connectors: 8-pin plugable signal input, 4-pin plugable sequential power, 4-terminal barrier strip, IEC AC power connector Construction: All steel; 16 ga. Due to our efforts for constant improvements, features and specifications are subject to change without notice. 73 volts @ 4 ohms, 2 volts @ 8 ohms Input Impedance: 20 k ohms, balanced Hum and Noise: >-115 dB, "A" weighted referenced to rated power @ 8 ohms Crosstalk: >-55 dB, "A" weighted referenced to rated power @ 8 ohms Current Draw @ 1/8 power: 575 watts @ 4 ohms, 380 watts @ 8 ohms Current Draw @ 1/3 power: 1185 watts @ 4 ohms, 860 watts @ 8 ohms Idle Current Draw: 35 VA in Standby Mode Maximum Current Draw: 2, 760 VA (time limited by breaker) Thermal Emissions (BTU/hr. ): 940 @ 1/8 power 4 ohms, 615 @ 1/8 power 8 ohms, 1830 @ 1/3 power 4 ohms, 1335 @ 1/3 power @ 8 ohms Cooling: 120 mm DC fan, off until heatsinks reach 45° C, then variable speed Controls: 2 rear panel attenuators, sequential turn-on / off Indicator LEDs: 2 Clip, 2 Signal, 2 LFC, 1 Protect, 1 Power Protection: Temp. , DC, turn-on bursts, subsonic, incorrect load or short Connectors: 8-pin plugable signal input, 4-pin plugable sequential power, 4-terminal barrier strip, IEC AC power connector Construction: All steel; 16 ga. Due to our efforts for constant improvements, features and specifications are subject to change without notice. 1% @ 200 W from 20 Hz - 20 kHz with both channels driven ICA 400V-100: <0. 15% @ 200 W from 20 Hz 20 kHz with both channels driven THD (one channel driven): ICA 400V-70: <0. 5 volts for rated output Input Impedance: 20 k ohms, balanced Hum and Noise: > -110 dB, "A" weighted referenced to rated power Crosstalk: ICA 400V-70: >-70 dB, "A" weighted referenced to rated power ICA 400V-100: >-65 dB, "A" weighted referenced to rated power Current Draw @ 1/8 power: ICA 400V-70: 415 watts ICA 400V-100: 385 watts Current Draw @ 1/3 power: ICA 400V-70: 600 watts ICA 400V-100: 565 watts Idle Current Draw: ICA 400V-70: 38 watts in Standby Mode ICA 400V-100: 43 watts in Standby Mode Maximum Current Draw: ICA 400V-70: 970 watts for rated power ICA 400V-100: 840 watts for rated power Thermal Emissions (BTU/hr. ): 500 @ 1/3 power, 350 @ 1/8 power Cooling: 80 mm DC fan, off until heatsinks reach 45o C, then variable speed Controls: 2 rear panel attenuators, sequential turn-on / off Indicator LEDs: 2 Clip, 2 Signal, 2 LFC, 1 Protect, 1 Power Protection: Temp. , DC, turn-on bursts, subsonic, incorrect load or short Connectors: 8-pin plugable signal input, 4-pin plugable sequential power, 4-terminal barrier strip, IEC AC power connector Construction: All steel; 16 ga. Due to our efforts for constant improvements, features and specifications are subject to change without notice. 3 dB at 1 watt Power Bandwidth: ICA 800V-70: 10 Hz - 100 kHz; +0, -3 dB at rated power ICA 800V-100: 10 Hz - 50 kHz; +0, -3 dB at rated power THD (two channels driven): ICA 800V-70: <0. 15% @ 400 W from 20 Hz 20 kHz with both channels driven ICA 800V-100: <0. 1% @ 400 W from 20 Hz - 20 kHz with both channels driven THD (one channel driven): <0. 5 volts for rated output Input Impedance: 20 k ohms, balanced Hum and Noise: > -108 dB, "A" weighted referenced to rated power Crosstalk: > -65 dB, "A" weighted referenced to rated power Current Draw @ 1/8 power: ICA 800V-70: 765 watts ICA 800V-100: 775 watts Current Draw @ 1/3 power: ICA 800V-70: 1, 100 watts ICA 800V-100: 1, 150 watts Idle Current Draw: 45 watts in Standby Mode Maximum Current Draw: ICA 800V-70: 1, 680 watts for rated power ICA 800V-100: 1, 700 watts for rated power Thermal Emissions (BTU/hr. ): 550 @ 1/8 power, 835 @ 1/3 power Cooling: 120 mm DC fan, off until heatsinks reach 45o C, then variable speed Controls: 2 rear panel attenuators, sequential turn-on / off Indicator LEDs: 2 Clip, 2 Signal, 2 LFC, 1 Protect, 1 Power Protection: Temp. , DC, turn-on bursts, subsonic, incorrect load or short Connectors: 8-pin plugable signal input, 4-pin plugable sequential power, 4-terminal barrier strip, IEC AC power connector Construction: All steel; 16 ga. Due to our efforts for constant improvements, features and specifications are subject to change without notice. 73 volts @ 4 ohms, 2 volts @ 8 ohms Input Impedance: 20 k ohms, balanced Hum and Noise: >-115 dB, "A" weighted referenced to rated power @ 8 ohms Crosstalk: >-55 dB, "A" weighted referenced to rated power @ 8 ohms Current Draw @ 1/8 power: 575 watts @ 4 ohms, 380 watts @ 8 ohms Current Draw @ 1/3 power: 1185 watts @ 4 ohms, 860 watts @ 8 ohms Idle Current Draw: 35 VA in Standby Mode Maximum Current Draw: 2, 760 VA (time limited by breaker) Thermal Emissions (BTU/hr. ): 940 @ 1/8 power 4 ohms, 615 @ 1/8 power 8 ohms, 1830 @ 1/3 power 4 ohms, 1335 @ 1/3 power @ 8 ohms Cooling: 120 mm DC fan, off until heatsinks reach 45° C, then variable speed Controls: 2 rear panel attenuators, sequential turn-on / off Indicator LEDs: 2 Clip, 2 Signal, 2 LFC, 1 Protect, 1 Power Protection: Temp. [. . . ] Never break off the ground pin on the power supply cord. For more information on grounding, write for our free booklet "Shock Hazard and Grounding. Power supply cords should always be handled carefully. Never walk on or place equipment on power supply cords. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PEAVEY ICA 400V

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PEAVEY ICA 400V will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag