If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PEAVEY SANCTUARY SSE 12. We hope that this PEAVEY SANCTUARY SSE 12 user guide will be useful to you.
Lastmanuals help download the user guide PEAVEY SANCTUARY SSE 12.
Manual abstract: user guide PEAVEY SANCTUARY SSE 12DATASHEET
Detailed instructions for use are in the User's Guide.
[. . . ] SPECIFICATIONS
SSETM 12
Description
The SSE is a new enclosure series featuring high power ratings with custom components, a sleek look and a unique, snap-in metal grille. The SSE 12 is a twoway system featuring the highly acclaimed Peavey 14XT titanium compression driver with the diverse Sound Guard IV tweeter protection network and Peavey Scorpion Pro 1200+ 12" woofer with 2. 5" (64 mm) voice coil for smooth response. [. . . ] DO NOT suspend this unit upside down using VersaMount system.
to 20 kHz pink noise with peaks of four times the RMS level, this strenuous test signal assures the user that every portion of this system can withstand today's high technology music. This rating is contingent upon having a minimum of 3 dB of amplifier headroom available.
Harmonic distortion
Second and third harmonic distortions vs. frequency are plotted in figures 5 & 6 for two power levels. Ten percent (10%) of rated input power and either one percent (1%) of rated input power or 1 Watt, whichever is greater. Distortion is read from the graph as the difference between the fundamental signal (frequency response) and the desired harmonic. As an example, a distortion curve that is down 40 dB from the fundamental is equivalent to 1% distortion.
Directivity factor, Q (Mean):
10. 27 ± 6. 07
Directivity index, Di (Mean):
9. 38 dB ± 2. 57 dB
Transducer complement:
Low Frequency Section: Peavey Scorpion® Pro 1200+ 12" woofer with 2. 5" (64 mm) voice coil High Frequency Section: Peavey 14XTTM titanium diaphragm compression driver on a 90° x 40° constant directivity horn
Dimensions (H x W x D):
Front: 24. 5" x 17. 43" x 13. 20" 622 mm x 443 mm x 335 mm Rear: 24. 5" x 13. 14" x 13. 20" 622 mm x 334 mm x 335 mm
Mounting
Caution: Before attempting to suspend or mount this speaker, consult a certified structural engineer. The speaker may fall due to improper installation, resulting in serious injury and property damage. DO NOT suspend or mount any other product or device from this enclosure. All associated rigging is the responsibility of others.
Box tuning frequency:
Low frequency section: 74 Hz
Net Weight:
40 lbs. (18. 1 kg)
Harmonic distortion:
1% rated power Second harmonic: 100 Hz: 0. 32% 1 kHz: 0. 10% Third harmonic: 100 Hz: 0. 40% 1 kHz: 0. 22% 10% rated power Second harmonic: 100 Hz: 0. 56% 1 kHz: 0. 79% Third harmonic: 100 Hz: 0. 79% 1 kHz: 0. 25%
Frequency response
This measurement is useful in determining how accurately a given unit reproduces an input signal. The frequency response of the SSE 12 is measured at a distance of 1 meter using a 1 Watt (into the nominal impedance) swept-sine input signal. As shown in figure 1, the selected drivers in the SSE 12 combine to give a smooth frequency response from 79 Hz to 17 kHz.
Architectural and Engineering Specifications
The loudspeaker system shall have an operating bandwidth of 79 Hz to 17 kHz. [. . . ] Peavey rates this loudspeaker system's power handling using a full-range form of the AES Standard 2-1984. Using audio band 20 Hz
Enclosure materials and finish
Trapezoidal, dado-joined 13 mm birch enclosure finished with a textured acrylic
2
SPECIFICATIONS
SSE TM 12
SPECIFICATIONS
SSETM 12
Amplitude Response (1W 1m On-Axis)
110 dB SPL (re 20 Pa) 100 90 80 70 60 20
50
100
200
Figure 1
500 1k Frequency (Hz)
2k
5k
10k
20k
Impedance
100 50 30 20
Z ( ) 10 5 3 2 1 20 50 100 200 500 1k Frequency (Hz) 2k 5k 10k 20k
Figure 2
Beamwidth
360 300 Beamwidth (Degrees) 180 140 100 80 60 40 30 20 Horizontal Vertical 50 100 200 500 1k Frequency (Hz) 2k 5k 10k 20k
Figure 3
Q & Directivity Index
100 20
Q
10 10
Di
1 20
50
100
200
Figure 4
500 1k Frequency (Hz)
2k
5k
10k
0 20k
3
3
Harmonic Distortion : 10% Rated Power
120 110 dB SPL (re 20 Pa) 100 90 80 70 60 50 20 50 100 200 500 1k Frequency (Hz) 2k 5k 10k 20k
Figure 5
2nd Harmonic 3rd Harmonic
Harmonic Distortion : 1% Rated Power
110 100 dB SPL (re 20 Pa) 90 80 70 60 50 40 20 50 100 200 500 1k Frequency (Hz) 2k 5k 10k 20k
Figure 6
2nd Harmonic 3rd Harmonic
4
SPECIFICATIONS
SSETM 12
Vertical Polar Patterns 6 dB per Division
90
o
90
60
o
o
90 60
o
o
60
o
30
o
30
o
30
o
0
o
0
o
0
o
-30
o
o
-30
o
o
-30
o
o
-60 -90
o
-60 -90
o
-60 -90
o
50 Hz
90
o
63 Hz
90 60
o o
80 Hz
90 60
o o
60
o
30
o
30
o
30
o
0
o
0
o
0
o
-30
o
o
-30
o
o
-30
o
o
-60 -90
o
-60 -90
o
-60 -90
o
100 Hz
90
o
125 Hz
90 60
o o
160 Hz
90 60
o o
60
o
o
30
o
30
30
o
0
o
0
o
0
o
-30
o
o
-30
o
o
-30
o
o
-60 -90
o
-60 -90
o
-60 -90
o
200 Hz
90
o
250 Hz
90 60
o o
315 Hz
90 60
o o
60
o
o
30
o
30
30
o
0
o
0
o
0
o
-30
o
o
-30
o
o
-30
o
o
-60 -90
o
-60 -90
o
-60 -90
o
400 Hz
500 Hz
630 Hz
5
Vertical Polar Patterns 6 dB per Division
90
o
90
60
o
o
90 60
o
o
60
o
30
o
30
o
30
o
0
o
0
o
0
o
-30
o
o
-30
o
o
-30
o
o
-60 -90
o
-60 -90
o
-60 -90
o
800 Hz
90
o
1 kHz
90 60
o o
1. 25 kHz
90 60
o o
60
o
30
o
30
o
30
o
0
o
0
o
0
o
-30
o
o
-30
o
o
-30
o
o
-60 -90
o
-60 -90
o
-60 -90
o
1. 6 kHz
90
o
2 kHz
90 60
o o
2. 5 kHz
90 60
o o
60
o
o
30
o
30
30
o
0
o
0
o
0
o
-30
o
o
-30
o
o
-30
o
o
-60 -90
o
-60 -90
o
-60 -90
o
3. 15 kHz
90
o
4 kHz
90
o o
5 kHz
90 60
o o
60
60
o
o
30
o
30
30
o
0
o
0
o
0
o
-30
o
o
-30
o
o
-30
o
o
-60 -90
o
-60 -90
o
-60 -90
o
6. 3 kHz
6
8 kHz
10 kHz
SPECIFICATIONS
SSETM 12
Vertical Polar Patterns 6 dB per Division
90
o
90
60
o
o
60
o
30
o
30
o
0
o
0
o
-30
o
o
-30
o
o
-60 -90
o
-60 -90
o
12. 5 kHz
16 kHz
7
Horizontal Polar Patterns 6 dB per Division
0 30
o o o
0
-30
o
o
0 -30
o
o
30
o
o
30
o
o
-30
o
60
-60
o
60
-60
o
60
-60
o
90
o
-90
o
90
o
-90
o
90
o
-90
o
50 Hz
0 30
o o o
63 Hz
0 -30
o o
80 Hz
0 -30
o o
30
o
o
30
o
o
-30
o
60
-60
o
60
-60
o
60
-60
o
90
o
-90
o
90
o
-90
o
90
o
-90
o
100 Hz
0 30
o o o
125 Hz
0 -30
o o
160 Hz
0 -30
o o
30
o
o
30
o o
o
-30
o
60
-60
o
60
-60
60
-60
o
90
o
-90
o
90
o
-90
o
90
o
-90
o
200 Hz
0 30
o o o
250 Hz
0 -30
o o
315 Hz
0 -30
o o
30
o
o
30
o o
o
-30
o
60
-60
o
60
-60
60
-60
o
90
o
-90
o
90
o
-90
o
90
o
-90
o
8
400 Hz
500 Hz
630 Hz
SPECIFICATIONS
SSETM 12
Horizontal Polar Patterns 6 dB per Division
0 30
o o o
0
-30
o
o
0
-30
o
o
30
o
o
30
o
o
-30
o
60
-60
o
60
-60
60
o
-60
o
90
o
-90
o
90
o
-90
o
90
o
-90
o
800 Hz
0 30
o o o
1 kHz
0 -30
o o
1. 25 kHz
0 -30
o o
30
o
o
30
o
o
-30
o
60
-60
o
60
-60
o
60
-60
o
90
o
-90
o
90
o
-90
o
90
o
-90
o
1. 6 kHz
0 30
o o o
2 kHz
0 -30
o o
2. 5 kHz
0 -30
o o
30
o
o
30
o o
o
-30
o
60
-60
o
60
-60
60
-60
o
90
o
-90
o
90
o
-90
o
90
o
-90
o
3. 15 kHz
0 30
o o o
4 kHz
0 -30
o o
5 kHz
0 -30
o o
30
o
o
30
o o
o
-30
o
60
-60
o
60
-60
60
-60
o
90
o
-90
o
90
o
-90
o
90
o
-90
o
6. 3 kHz
8 kHz
10 kHz
9
Horizontal Polar Patterns 6 dB per Division
0 30
o o o
0
-30
o
o
30
o
o
-30
o
60
-60
o
60
-60
o
90
o
-90
o
90
o
-90
o
12. 5 kHz
16 kHz
10
SPECIFICATIONS
SSETM 12
Input Plate
11
www. sanctuary-series. com
80305311
Features and specifications subject to change without notice.
Peavey Electronics Corporation
711 A Street
Meridian, MS 39301
(601) 483-5365
FAX (601) 486-1278
©2004
Printed in the U. S. A. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE PEAVEY SANCTUARY SSE 12 Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service. Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PEAVEY SANCTUARY SSE 12 will begin.