User manual PENTAX *ISTDL2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PENTAX *ISTDL2. We hope that this PENTAX *ISTDL2 user guide will be useful to you.

Lastmanuals help download the user guide PENTAX *ISTDL2.


Mode d'emploi PENTAX *ISTDL2
Download
Manual abstract: user guide PENTAX *ISTDL2

Detailed instructions for use are in the User's Guide.

[. . . ] SLR Digital Camera Operating Manual For optimum camera performance, please read the Operating Manual before using the camera. Thank you for purchasing the PENTAX F Digital Camera. Please read this manual before using the camera in order to get the most out of all the features and functions. Keep this manual safe, as it can be a valuable tool in helping you to understand all the camera's capabilities. Lenses you can use In general, lenses that can be used with this camera are DA, D FA and FA J lenses and lenses that have an Aperture s (Auto) position. To use any other lens or accessory, see p. 37 and p. 184. [. . . ] Corrects sensitivity automatically in the range of ISO 200 to 1600. Corrects sensitivity automatically in the range of ISO 200 to 3200. Set in [ISO Corction in AUTO] in the [A Custom Setting] menu. (p. 102) ISO Corction in AUTO ISO ISO ISO ISO 200-800 200-400 200-1600 200-3200 Corrects sensitivity automatically in the range of ISO 200 to 800 118 Sensitivity is not corrected in the following. · Exposure mode is a (Manual) or p (Bulb) mode · Flash is discharged · Auto bracketing · EV Compensation ISO Sensitivity Warning Display ISO Sensitivity Warning appears in the viewfinder when a sensitivity value of your choice is reached or exceeded. Set a sensitivity that is not regularly used to avoid forgetting to reset when sensitivity is raised. ISO Sensitivity Warning is not displayed by default. 1 2 Off ISO 400 ISO 800 ISO 1600 ISO 3200 ISO Sensitivity Warning is not displayed. ISO Sensitivity Warning is displayed when ISO 400 is set or exceeded. ISO Sensitivity Warning is displayed when ISO 800 is set or exceeded. ISO Sensitivity Warning is displayed when ISO 1600 is set or exceeded. ISO Sensitivity Warning is displayed when ISO 3200 is set. 5 3 4 5 Function Reference Set in [ISO Snstvty Wrn Dspl] in the [A Custom Setting] menu. (p. 102) ISO Snstvty Wrn Dspl Off ISO ISO ISO ISO 400 800 1600 3200 ISO sensitvty wrning not displayed in vewfnder o (ISO Sensitivity Warning) appears in the viewfinder when the set sensitivity is set or exceeded. ISO Sensitivity Warning is not displayed if sensitivity is automatically corrected (p. 117). 119 Setting the Color Space You can set the color space to use. The default setting is [sRGB]. 1 2 sRGB AdobeRGB Sets to sRGB color space. Sets to AdobeRGB color space. Set in [Color Space] in the [A Custom Setting] menu. (p. 103) Color Space sRGB AdobeRGB Sets to sRGB color space 5 Function Reference File names differ depending on the color space setting as shown below. For sRGB : IMGPxxxx. JPG For AdobeRGB : _IGPxxxx. JPG [xxxx] is the file number and numbering continues from the last stored file number. Color Space Color ranges for various input/output devices, such as digital cameras, monitors, and printers, differ. This color range is called the Color Space. To recreate different color spaces in different devices, standard color spaces have been proposed. sRGB is mainly used for devices such as a PC. AdobeRGB covers a wider area than sRGB and is used for occupational uses such as industrial printing. An image created in AdobeRGB may appear lighter than an image created in sRGB when output from a sRGB compatible device. 120 Focusing You can focus with the following methods. = Autofocus \ Manual focus The camera is focused when the shutter release button is pressed halfway. Manually adjust the focus. Using the Autofocus You can choose the autofocus area from [Wide] and [Spot]. [. . . ] Each product marketed is identical to the representative unit tested and found to be compliant with the standards. Records maintained continue to reflect the equipment being produced can be expected to be within the variation accepted, due to quantity production and testing on the statistical basis as required by 47CFR §2. 909. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. The above named party is responsible for ensuring that the equipment complies with the standards of 47CFR §15. 101 to §15. 109. Product Name: PENTAX Digital Still Camera Model Number: F Contact person: Customer Service Manager Date and Place: January, 2006, Colorado Information on disposal for users 1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PENTAX *ISTDL2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PENTAX *ISTDL2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag