If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PENTAX INFRARED REMOTE CONTROL SYSTEM. We hope that this PENTAX INFRARED REMOTE CONTROL SYSTEM user guide will be useful to you.
Lastmanuals help download the user guide PENTAX INFRARED REMOTE CONTROL SYSTEM.
Manual abstract: user guide PENTAX INFRARED REMOTE CONTROL SYSTEM
Detailed instructions for use are in the User's Guide.
[. . . ] Creating / Selecting a Job File
To create a new job file:
POWER TOPO LITE MAIN MENU
FILE F1 TO 123 F4
ENT
input a new job name by using
ENT
F1
F5
,
0
9
DEF
.
Or to select a job file:
POWER TOPO LITE MAIN MENU
FILE F1 F4 ENT
x2
ENT
x2
select a job file by
F1
F4
NOTE: Once a job file is created or selected, it is effective until a new job file is created or another job file is selected. The default job file "PENTAX" is provided permanently so that data is stored even when no user defined job file exists.
3. Input a Known Point Coordinate
To input and store a known point coordinate;
POWER TOPO LITE MAIN MENU
VIEW F3 TO 123 F4
ENT
x2
ENT
input a Point Name by using repeat to input value
F1 ESC
F5
,
0
SAVE F1
9
DEF
.
ESC
to quit
x2
input PC (point code)
ENT
9
NOTE: There are other functions in VIEW menu; Graphical View, Edit Rectangular Data, and Edit Polar Data. For detail of these functions, please refer to the instruction manual of PowerTopoLite.
To input PC (point code):
move cursor to PC
ENT ENT
select a PC from the list by
TO 123 F1 F5
ENT F1 F4
x2
input a new PC by
0
9
DEF
.
NOTE: PC list is displayed only when point codes are stored in the job named "PointColeList" "PointCodeList" job can be . [. . . ] 4. 2 Orientation (Station Point H. Angle Setup) To input a given angle:
INPUT F2
input value by using
0
9
DEF
.
ENT
x2
MEASUREMENT SCREEN
Or to set the angle 0°:
0 SET F1
x2
ENT
MEASUREMENT SCREEN
Or to calculate by the Back Sight Point:
BSP F5
input value or select from the list
ENT
MEASUREMENT SCREEN
LIST F2
ENT
ACCEPT F5
aim Back Sight Point
11
4. 3 Measurement To select the Target type:
PAGE F5
x2
repeat
TARGET F2
until the desired target type is selected
PAGE F5
NOTE: You can check the selected target type at the left side of the Battery mark in the top line of the screen. To measure: Or to start tracking:
MEAS F1
MEAS F1
x2
PAGE F5
NOTE: EDM measurement mode can be changed by
EDM F1
x2
select and change the EDM mode
To input the point information:
EDIT F4
move cursor by input values by using
F3
,
F4 TO 123
, ,
ENT
F1
F5 ESC
0
9
DEF
.
ACCEPT F5 ENT
RETURN TO THE MEASUREMENT SCREEN
ENT
repeat to input value
to quit
input point code
To save the point information:
SAVE F2
(next measurement)
Or to measure and save:
ME/SAVE F3
(next measurement)
NOTE: the Point number is automatically incremented or decremented to make rapid continuous measurements possible.
12
4. 4 Offset Measurement For Radial Offset (the horizontal distance offset along the line of measurement):
MEASUREMENT SCREEN
PAGE F5
OFFSET F2
ENT
input value by using
RETURN TO THE MEASUREMENT SCREEN
0
9
DEF
.
ENT
ESC
ACCEPT F5
For Tangential Offset:
MEASUREMENT SCREEN
PAGE F5
OFFSET F2 F4
x3
ENT
ENT
input value by using ,
0
9
DEF
.
RETURN TO THE MEASUREMENT SCREEN
For Distance Offset (slope distance):
MEASUREMENT SCREEN
PAGE F5
OFFSET F2 F4
x2
ENT
ENT
input value by using ,
0
9
DEF
.
ESC
ACCEPT F5
RETURN TO THE MEASUREMENT SCREEN
NOTE: The Offset values are cleared once the measurement is saved.
4. 5 Remote measurement To enter the Remote mode:
MEASUREMENT SCREEN
PAGE F5
REMOTE F1
x2
PAGE F5 ACCEPT F5 ENT
x2
MEAS F1 SAVE F2
RETURN TO THE MEASUREMENT VALUES ARE UPDATED BY TURNING THE TELESCOPE
EDIT F4
Input PN, PH
ESC
(next measurement)
input PC
or
MEASUREMENT SCREEN
MEAS F1
PAGE F5 ESC
REMOTE F1 ACCEPT F5 ENT
x2
REMOTE MODE
MEASUREMENT VALUES ARE UPDATED BY TURNING THE TELESCOPE
EDIT F4
Input PN, PH
SAVE F2
(next measurement)
input PC
13
NOTE: Remote values are calculated based on the assumption of the reference plane. Three types of the reference plane are available in PowerTopoLite; Cylindrical surface, Fixed plane (default) and Rotated plane. To change the reference plane type:
POWER TOPO LITE MAIN MENU
PAGE F5
x2
PREF F4 F4
x4
ENT ACCEPT F5
ENT
select by using
F3
,
F4
To quit the Remote mode:
PAGE F5 REMOTE F1
x2
MEASUREMENT SCREEN
5. Polar Coordinate Measurement
POWER TOPO LITE MAIN MENU
MEAS F2 F4
ENT
STATION POINT SETUP
5. 1 Station Point Setup To input the point information:
ENT
input Point Name by
ESC
TO 123 F1 F5
,
F1
0
9
DEF
.
H. ANGLE SETUP
ENT
repeat to input value
to quit
SAVE
or confirm "ppm"
ENT
NOTE: Input items are PN (point name), IH (instrument height), PC (point code), TEMP (temperature), PRESS (atmospheric pressure) and ppm. "TEMP" and "PRESS" can be input only when "Atmospheric Correction" is set to "ATM INPUT". "ppm" can be input only when "Atmospheric Correction" is set to "ppm INPUT". The input item (cursor position) may be selected by
F3
,
ENT F4
14
5. 2 Orientation (Station Point H. Angle Setup) Only when the orientation of the horizontal angle is required, proceed according to the following procedure. Otherwise, just pass this step by ENT To input a given angle:
INPUT F2
input value by using
0
9
DEF
.
ENT
x2
MEASUREMENT SCREEN
Or to set the angle 0°:
0 SET F1
x2
ENT
MEASUREMENT SCREEN
Or to calculate by Inverse:
INVERS F5 LIST F2 ENT LIST F2
select Start Point from the List
ENT ACCEPT F5 ENT
ENT
ACCEPT F5
select End Point from the List
x2
MEASUREMENT SCREEN
5. 3 Measurement To select the Target type:
PAGE F5
x2
repeat
TARGET F2
until the desired target type is selected
PAGE F5
NOTE: You can check the selected target type just at the left of the Battery mark in the top line of the screen.
To measure: Or to start tracking:
MEAS F1
MEAS F1
x2
NOTE: EDM measurement mode can be changed by
PAGE F5
x2
EDM F1
select and change the EDM mode
15
To input the point information:
EDIT F4 ENT
input Point Name by
ESC
TO 123 F1 F5
,
0
9
DEF
.
ENT
repeat to input value
to quit
(point code)
ACCEPT F5 ENT
RETURN TO THE MEASUREMENT SCREEN
Input PC
To save the point information:
SAVE F2
(next measurement)
Or to measure and save:
ME/SAVE F3
(next measurement)
NOTE: The point number is automatically incremented or decremented for rapid continuous measurements.
5. 4 Offset measurement For Radial Offset (horizontal distance offset along with the line of measurement):
MEASUREMENT SCREEN
PAGE F5
OFFSET F2
ENT
input value by using
RETURN TO THE MEASUREMENT SCREEN
0
9
DEF
.
ENT
ESC
ACCEPT F5
For Distance Offset (slope distance offset):
MEASUREMENT SCREEN
PAGE F5 ENT
OFFSET F2 ESC
ENT
input value by using
RETURN TO THE MEASUREMENT SCREEN
0
9
DEF
.
ACCEPT F5
NOTE: The Offset values are cleared once the measurement is saved.
16
6. Free Stationing
POWER TOPO LITE MAIN MENU
FREE F4
input Inst. Height (IH) by using
0
9
DEF
.
ENT
KNOWN POINT SETUP
6. 1 Known Point setup Select the point from the stored data:
LIST F2
select the point by
FIND PN F2 F4
ENT
ACCEPT F5
MEASUREMENT SCREEN
Or input PN which is already stored in memory to call and display the known coordinate. · Polar coordinates data of back sight and station points can not be seen in the POLAR EDIT function, but it is sent properly in SEND POLAR DATA function.
22
To start Traverse:
POWER TOPO LITE MAIN MENU
PAGE F5
x2
TRAV F1
TRAVERSE MENU
9. 1 Measurement at the start point Start the traverse from the start point measurement.
TRAVERSE MENU
ENT
STATION SETUP
Station Setup:
ENT
input Point Name by
ESC
TO 123 F1 F5
,
F5
0
9
DEF
.
H. ANGLE SETUP
ENT
repeat to input value
to quit
ACCEPT
or confirm "ppm"
ACCEPT F5
Orientation (Station Point Setup):
INPUT F2
input value by using
0
9
DEF
.
ENT
x2
SIDE SHOTS
or to set the angle 0°:
0 SET F1
x2
ENT
SIDE SHOTS
or to calculate by the known points (Start point and End point):
INVERS F5 LIST F2 ENT LIST F2
select Start Point from the List
ENT ACCEPT F5 ENT
ENT
ACCEPT F5
select End Point from the List
x2
SIDE SHOTS
Side shot measurement:
repeat
MEAS F1
,
EDIT F4
,
SAVE F2 MEAS F1
for all side shots ,
EDIT F4
finish measurements by
,
ENT
at the Corner Point
ESC
TRAVERSE MENU
23
NOTE: The corner point is the foresight of the traverse, which is ENT the next instrument point and must be ended by
If required, select the target by
PAGE F5
x2
TARGET F2
before each measurement.
9. 2 Measurement at a Corner Point
TRAVERSE MENU
ENT F4
Station Setup:
(the last corner point is displayed as Station)
ACCEPT F5
NOTE: Input Instrument Height (IH), if necessary.
Orientation:
(sight the back sight point)
ENT
Side shot:
repeat
MEAS F1
,
EDIT F4
,
SAVE F2 MEAS F1
for all side shots ,
EDIT F4
finish measurements by
,
ENT
at the Corner Point
ESC
TRAVERSE MENU
NOTE: The corner point is the foresight of the traverse, which is ENT the next instrument point and must be ended by .
If required, select the target by
PAGE F5
x2
TARGET F2
before each measurement.
24
9. 3 To finish the traverse measurement Fixed traverse: Measure the known point and press corner point.
ENT ENT
at the last
Closed traverse: Measure the start point and press at the last corner point with the different Point Name. NOTE: Use a different point name (PN) when you measure the start point as the last corner point. For example, change "T1" to "T1-1" etc. Open traverse: The closing errors are not calculated. No need to end the measurement by pressing ENT .
9. 4 Traverse Calculation To Start Fixed traverse calculation:
TRAVERSE MENU
F4
x2
ENT
NOTE: To select CLOSE TRAVERSE CALC. : To select OPEN TRAVERSE CALC. : Start Point Coordinate setup:
LIST F2
F4
x3 x4
F4
select the point by
FIND PN F2 F4
ENT
ACCEPT F5
END POINT SETUP
or to input the known coordinate;
ENT
input Point Name by
ESC
TO 123 F1 F5 ACCEPT F5
,
0
9
DEF
.
ENT
input the next value or
to quit
END POINT SETUP
25
End Point Coordinate setup: the same operation as in the above.
NOTE: The End Point Coordinate Setup is required only in the fixed traverse. Result of Traverse Calculation: To see the result of each corner point: To see all points in order: To save all results:
F1
or or
F2
F3
F4
ACCEPT F5
TRAVERSE MENU
10. Cogo
To access COGO menu and select calculation type:
POWER TOPO LITE MAIN MENU
PAGE F5
CALC F2
ENT
select calc. type by
F3
or
F4
ENT
Input required parameters:
ENT
input parameters by terminating with
ACCEPT F5
or
ENT
each time
RESULT SCREEN
Save the result:
ENT
input point name and point code
ACCEPT F5
RETURN TO PARAMETER SCREEN
The required calculation parameters and the output are as follows (p27):
26
1 Inverse
SP (Start Point) EP (End Point) CO (Known point coordinate) DI (Distance to the unknown point) BE (Direction Angle to the unknown point) Coordinates of three points (P1, P2, P3)
Direction Angle (SP->EP) H, V, S Distance Coordinate of the unknown point
2 Point Coordinate
3 Circle Radius
Coordinate of centerpoint of the arc, Radius of the arc Coordinates of intersect points (P1, P2)
4 Line-Arc Intersection
SP (Start point of the line) EP (End point of the line) CP (Center point of the circle) R (Radius of the circle) S1 (Start point of the 1st line) E1 (End point of the 1st line) S2 (Start point of the 2nd line) E2 (End point of the 2nd line) C1 (Center Point of the 1st circle) R1 (Radius of the 1st circle) C2 (Center Point of the 2nd circle) R2 (Radius of the 2nd circle) SP (Start point of the line) EP (End point of the line) OP (Offset Point)
5 Line-Line Intersection
Coordinate of the intersect point
6 Arc-Arc Intersection
Coordinates of intersect points (P1, P2)
7 Distance Offset
Coordinate of the intersect point of the line and a perpendicular line from the offset point. Distance of the intersect point from the SP of the line Coordinate of the offset point
8 Point Distance Offset
SP (Start point of the line) EP (End point of the line) DI (Distance on the line from SP) OD (Offset distance from the line) SP (Start Point of the arc) EP (End point of the arc) R (Radius of the arc) DI (Distance on the arc from SP) OD (Offset distance from the arc)
9 ARC Distance Offset
Coordinate of the offset point
27
11. Area Calculation
To start area calculation:
POWER TOPO LITE MAIN MENU
PAGE F5
CALC F2 F4
ENT
select points of the polygon by repeating select (
ACCEPT F1
RESULT SCREEN
F3
or
F4
) and
ENT
To return to the calculation menu screen:
ESC
RESULT SCREEN
x2
CALCULATION MENU SCREEN
NOTE: This function calculates the length of 2D and 3D contour of a polygon, and the 2D surface (area) of the polygon. The polygon is defined by selecting points in such a way that the contour segments of the polygon do not intersect. [. . . ] F5
RESULT SCREEN DISTANCE FROM THE PREVIOUS TARGET POINT
To change the reference to the present point:
RESULT SCREEN DISTANCE FROM THE PREVIOUS TARGET POINT
ENT
x2
(repeat reference point measurement)
To return to PowerTopoLite Main menu:
ENT
RESULT SCREEN POWER TOPO LITE MAIN MENU
15. VPM (Virtual Plane Measurement)
To start VPM:
POWER TOPO LITE MAIN MENU
PAGE F5
VPM F3
STATION POINT SETUP
Station point setup:
LIST F2
select the point by
FIND PN F2 F4
ENT
ACCEPT F5
H. ANGLE SETUP
30
H. angle setup: To input a given angle:
INPUT F2
input the value by
0
9
DEF
.
ENT
x2
THREE POINTS MEASUREMENT
Or to set the angle 0°:
0 SET F1
x2
ENT
THREE POINTS MEASUREMENT
Or to calculate by the Back Sight Point:
BSP F5 ENT
Input value or select from the List
THREE POINTS MEASUREMENT
LIST F2
SAVE F1
or
ACCEPT F5
Measure three points to define the plane:
MEAS F1
if necessary,
SAVE F2
ENT
(repeat measurements of remaining two points)
VPM SCREEN
Virtual plane measurement:
aim a point on the plane if necessary,
SAVE F2
To return to PowerTopoLite Main menu:
ESC
VPM SCREEN POWER TOPO LITE MAIN MENU
16. Changing Preference
To access Preference menu:
POWER TOPO LITE MAIN MENU
PAGE F5
x2
PREF F4
select an item by or
ENT F4 F5
F3 ACCEPT
or
F4
ENT
select an option by
F3
POWER TOPO LITE MAIN MENU
Preference List (page 32)
31
Item ENGLISH X Y Z BASE DIRECTION RIGHT ANGLE HEIGHT CW 10 KEY SYSTEM (ABC) PROCESS TYPE FIXED PLANE ALL IN ONE INFO. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE PENTAX INFRARED REMOTE CONTROL SYSTEM
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PENTAX INFRARED REMOTE CONTROL SYSTEM will begin.