User manual PENTAX MACROPHOTO STAND & LIGHTING TABLE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PENTAX MACROPHOTO STAND & LIGHTING TABLE. We hope that this PENTAX MACROPHOTO STAND & LIGHTING TABLE user guide will be useful to you.

Lastmanuals help download the user guide PENTAX MACROPHOTO STAND & LIGHTING TABLE.


Mode d'emploi PENTAX MACROPHOTO STAND & LIGHTING TABLE
Download
Manual abstract: user guide PENTAX MACROPHOTO STAND & LIGHTING TABLE

Detailed instructions for use are in the User's Guide.

[. . . ] In case the reflectorless measurement results in low accuracy, perform the distance measurement by Reflector sheet or Prism. (R-322NX, R-323NX, R-325NX, R-335NX, R-315NX, ) Batter y & Charger Use the battery charger that is suitable to the battery you are using. If water should happen to splash on the instrument or the battery, wipe it off immediately and allow it to dry in a dry location. Auto focus The Auto focus may not function under every condition depending on brightness, contrast, and the shape and size of the target. In such a case, use the Power Focus buttons or the manual focus ring. [. . . ] 2. 1 Help menu While the screen is in MODE A or MODE B, + Select a desired item by Change the setting or x2 NOTE: Some items have sub-menus where the selecting procedure by using F1 - F4 is again repeated. 2. 2 "007" code While the screen is in MODE A or MODE B, Input 007 code by using Change the setting x2 NOTE: Some items have sub-menus where the selecting procedure by using F1 - F4 is again repeated. 2. 3 Instrument setting items See chart on page 15 14 007 code 401 PRISM CONST SHEET CONST SHOT CONT SHOT INPUT HELP menu list TARGET CONST 402 501 502 ATM CORR MEAS. MIN DISP SHOT COUNT 503 504 505 508 509 510 511 512 514 515 PRIM. MEAS KEY SEC. MEAS KEY AUTO MEAS. PRIORITY DISP CRV/REF CORR MIN UNIT ANG. STYLE DIST. BUZ QUAD BUZ AUTO OFF EDM OFF ILLU. OFF MEAS. SIGNAL PRIORITY SELECT 517 520 LD PLUM. TILT DISP. UNIT RANGE MESSAGE SETUP TEMP. UNIT PRESS UNIT BAUD RATE DATA LENGTH PARITY BITS STOP BITS SIGNAL CONTROL XON/XOFF THROUGH COMMAND COMP AXIS LD PLUM. &E. VIAL 521 REF. LESS RANGE 522 701 QUICK MEAS ATM UNIT 702 703 801 DIST. UNIT ANG. UNIT SET UP COM. Default -30mm 0mm AUTO COARSE 1 time 01 times 0. 14 FINE Z. 0 ON OFF 10 MIN 3 MIN 3 MIN MARK MEAS SHOT TRACK CONT NIL HA/HD/VD 3 Axis (2/3"model) or 2 Axis OFF (when Power On) OFF COARSE NORMAL ON (when Range is LONG) EACH TIME (w/ Power ON) OFF Centigrade hPa m DEG 1200 8 NIL 1 ON ON NIL Other options 0mm, INPUT INPUT ATM INPUT, ppm INPUT, NIL FINE 3 times, 5 times, INPUT (input) 0. 2, NIL COARSE H. 0, COMPASS OFF ON 20 MIN, 30 MIN, NIL 5 MIN, 10 MIN, NIL 5 MIN, 10 MIN, NIL VALUE MEAS CONT, TRACK SHOT, TRACK CONT TRACK SHOT, MEAS CONT, MEAS SHOT MEAS. , TRACK HA/VA/SD, HA/VA/HD/SD/VD 2 Axis (2/3" model), 1Axis, , NIL ON (automatically ON) ON FINE LONG OFF PERMANENT ON Fahrenheit mmHg, inchHg ft, ft+inch DEC, GRD, MIL 2400, 4800, 9600 7 EVEN, ODD 2 OFF OFF a, b, c, d, e, f 3. Basic Field Checking Procedures Checks and Adjustments should be performed before and during measurement. 3. 1 Elec tronic Vial To display vials: or (from measurement screen) Check if the bubble stays at the center of each vial, when rotating the instrument by 180°. To adjust the vials: + instruction on the screen operate according to the NOTE: Press these two keys for 1 second longer, then release key first. 3. 2 Laser Plummet To activate the laser plummet: (for the first time after Power on) or (from measurement screen) Check if the laser spot on the ground stays at the same position when rotating the instrument around the vertical axis. To adjust the laser plummet: Contact your local dealer 3. 3 Laser Pointer To activate the laser pointer: or (from measurement screen) Check if the projected laser spot points at the same position that is aimed by the center of the cross-hair line of the telescope. The instrument is designed to correct for weather conditions automatically if the temperature and pressure are input. Circular level 8'/2mm Plummet Visible Laser, ±0. 8mm (instrument height 1. 5m) Base Detachable Shifting Fixed Detachable Water resistant IP56 (instrument only) Ambient temperature -20°C ~ +50°C / -4°F ~122°F (Working range) Tripod thread 5/8" x 11 35mm x 2 5/8" x 11 Dimensions/Weight Instrument 177(W) x 343(H) x 177(L)mm Weight (incl. Battery) 5. 7kg 5. 5kg 5. 7kg Carrying case 268(W) x 442(H) x 465(L)mm/3. 9kg Batter y pack BP02 Power source Ni-MH (Rechargeable)(4300mAh) , DC6V 19 Operation time R-322NX R-323NX R-325NX R-335NX R-315NX R-322EX R-323EX R-325EX R-335EX R-315EX R-326 EX Continuous Approx. 5 hrs (ETH+EDM), 12 hrs (ETH) with Approx. 380g Charger BC03 and AC Adapter AC01 Input voltage (AC01) AC 100~240V (AC01) Output voltage (BC03) DC7. 5V (BC03) Weight 280g Internal Memor y Coordinates data 18. 600 points 16. 000 points 12. 000 points Date Clock NX MODEL Yes Yes EX MODEL Yes No No NOTE: * The measurement range may vary by measurement conditions. * Normal conditions: 20km visibility with slight shimmer. * Good conditions: 40km visibility, overcast, no heat, no shimmer and moderate wind. * Reflector sheet: PENTAX genuine Reflector sheet (5cm x 5cm). * Quick mode, which is effective only under Normal mode (1mm) setting, functions with Prism and Reflector Sheet. It is incorporated in all X series models and effective up to 500m. * When Quick Mode is on, the EDM accuracy using Prism and Reflector Sheet is ±(3+2ppm x D)mm. [. . . ] B) Operation, maintenance or adjustment other than those specified in this instruction manual may result in hazardous radiation exposure. C) Maintenance and repair not covered in this manual must be done by an authorized Pentax dealer. D) The Laser beam emission by the Distance measurement can be terminated by pressing key. E) Pressing keys can terminate the laser beam emission by the laser pointer. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PENTAX MACROPHOTO STAND & LIGHTING TABLE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PENTAX MACROPHOTO STAND & LIGHTING TABLE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag