User manual POLTI LECOLOGICO SPECIAL ALLERGY

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual POLTI LECOLOGICO SPECIAL ALLERGY. We hope that this POLTI LECOLOGICO SPECIAL ALLERGY user guide will be useful to you.

Lastmanuals help download the user guide POLTI LECOLOGICO SPECIAL ALLERGY.


Mode d'emploi POLTI LECOLOGICO SPECIAL ALLERGY
Download
Manual abstract: user guide POLTI LECOLOGICO SPECIAL ALLERGY

Detailed instructions for use are in the User's Guide.

[. . . ] 21 27 21 17 18 9 8 7 3 4 16 19 18 18a 24 25 26 6 10 11 5 O O1 2 22 23 20 19a 18b 12 4 A 13 14 15 L A1 F 1 O2 5-A J O3 G C M N D I H B B1 E LECOLOGICO SPECIAL ALLERGY Dear Customer, Thank you for choosing Polti thus showing your trust in our company. By choosing Lecologico Special Allergy, you show your interest in the health of your family, because Lecologico Special Allergy Polti is a friend of the environment but an enemy of dust, pollen, dust mites and their associated allergens. Thanks to its EcoActive-Filter, Lecologico Special Allergy holds dirt in the water which, once dirty, can be poured away, preventing dust and micro-organisms from spreading again everywhere. Moreover, EcoActive-Filter sets you free from dusty bags and all the problems associated with dust bags. [. . . ] Bioecologico is available in the "neutral" unscented version supplied with Lecologico Special Allergy, or in mountain pine or citrus. HOW TO EMPTY AND CLEAN THE WAT E R TA N K · Switch off the appliance at the mains switch (11) and disconnect the power supply cable from the mains. · Disconnect the tube from the junction by turning it inversely with rispect to paragraphs "preparations for use" (fig. 3). · Push the opening button (8) on the upper cover (7). · Lift the cover (7) by turning it upwards as indicated in fig. · Lift the container handle (6) by taking it to the height of the tube hole as in fig. · Take out the container (5) by pulling it out of the appliance (fig. 8) LECOLOGICO SPECIAL ALLERGY · Pull the water filter cage (20) upwards and then pull it out (fig. · Empty the container (5) and rinse it. · Unhook the elbow tube locking ring (25) by pulling it outwards (fig. · Pull the elbow tube (26) from the filter body (24) until it slips off (fig. · Divide all the components as described in the key and then rinse them under running water (If the sponge filters are worn out replace them with original Polti spare parts). · To help with the water bucket (5) a cleaning brush is included (5-A), which can be used to clean the tubes joint and the internal parts and the accessories. NOTE: do not use the brush to clean the appliance externally · Before putting the sponge filters (22-23) back, wring them by using a cloth so as to completely dry them. · Reassemble the water filter group (20) by repeating the operation in reverse. NOTE: before reassembling the water filter, make sure that all the parts have been properly dried. · Put the filter group (20) back into the container (5) so as to insert the elbow tube (26) between the two projections of the container (fig. · Gently push the water container handle (6) until the two slots on the handle fit with the two pins (4) on the appliance (fig. · Before storing the appliance or before using it again, make a drying cycle as described in the "Drying cycle" paragraph. · We advise you to clean the appliance after each use. · Remove the back sponge filter (19a). · Connect the supply cable plug (27) to the mains. · The first stage of the luminous indicator light (13) will start to flash. · To reactivate the appliance, keep the mains On/Off switch (11) pushed until the machine reaches the maximum speed. [. . . ] Make sure that the two sections fit together properly. A U T O M AT I C C A B L E W I N D E R Before putting the vacuum cleaner away, rewind the power cable by pressing the button (2), as shown in fig. 21, being careful to accompany it during rewinding. LECOLOGICO SPECIAL ALLERGY GENERAL MAINTENANCE Before maintenance, make sure that the supply cable is not connected to the mains. Cleaning or replacing the HEPA filter · Move the two air outlet filter grill opening levers (18) at the same time by pulling them towards the inside so as to allow the air outlet filter grill (17) to unhook (fig. · Remove the HEPA filter (19) from its location, tap it and, if necessary, replace it with an original Polti spare part. · Reassemble the Hepa filter (19) and the air outlet filter grill (17), inserting first the two pins 18a into the locking holes 18b (fig. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE POLTI LECOLOGICO SPECIAL ALLERGY

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual POLTI LECOLOGICO SPECIAL ALLERGY will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag