Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PROCEED AMP2. We hope that this PROCEED AMP2 user guide will be useful to you.
Lastmanuals help download the user guide PROCEED AMP2.
Detailed instructions for use are in the User's Guide.
[. . . ] AMP 2 & AMP 3 Power Amplifiers
PR O C E E D
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.
CAUTION
RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE COVER. REFER SERVICING TO QUALIFIED PERSONNEL.
The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
Marking by the "CE" symbol (shown left) indicates compliance of this device with the EMC (Electromagnetic Compatibility) and LVD (Low Voltage Directive) standards of the European Community.
The information contained in the manual is subject to change without notice. The most current version of this manual will be posted on our web site at http://www. madrigal. com.
2
Important Safety Instructions
Please read all instructions and precautions carefully and completely before operating your Proceed power amplifier.
1.
ALWAYS disconnect your entire system from the AC mains before connecting or disconnecting any cables, or when cleaning any component. This product is equipped with a three-conductor AC mains power cord which includes an earth ground connection. [. . . ] Note that if the amplifier has been disconnected from the AC mains power by depressing the front panel power button, it cannot respond to a remote turn-on command from a control unit.
2
INDICATOR LIGHT The indicator light glows either amber or red, depending on the operational status of your AMP Amber indicates that the AMP is on and ready . When the indicator light is glowing red, the unit is in standby (see 1 above). If the indicator light is completely off, the amplifier is not receiving power. Check your AC connections and the rearpanel AC fuse.
12
when viewed from the front
remote turn-on mains fuse
100-120VAC: 8A 3AG fast acting 200-240VAC: 4A 3AG fast acting
+ outputs
+ outputs
~ ac mains
PUSH
input select
PUSH
input select
21 3
21 3
1
2
remote turn-on
3
4
when viewed from the front
5
(right)
67
when viewed from the front when viewed from the front
when viewed from the front
(right)
channel 2
channel 1
(left)
mains fuse
100-120VAC: 12A 3AB fast acting 200-240VAC: 6A 3AG fast acting
+ outputs
+ outputs
channel 2 (center)
+ outputs
~ ac mains
PUSH
input select
PUSH
input select
PUSH
input select
21 3
21 3
21 3
Rear Panel
Caution!
Turn the volume on your preamplifier all the way down before attempting to connect anything to your Proceed AMP 2 or AMP 3.
1
AC MAINS RECEPTACLE Connect the AC power cord (included in the accessory pack) to the I. E. C. standard AC receptacle on the rear panel of the AMP then to the AC mains , outlet.
Warning!
The Proceed AMP has been safety-tested and is designed for operation with a three-conductor power cord. Do not defeat the "third pin" or earth ground of the AC power cord.
channel 3
channel 1
(left)
13
2
REMOTE TURN-ON JACK A 1/8" "mini" jack above the AC mains receptacle on the rear panel allows remote-controlled turn-on (that is, toggling between operate and standby) of the Proceed AMP This remote "trigger" will be operated by a . 312 volts DC positive-polarity pulse, of at least 100 milliseconds duration, with tip polarity as shown below:
Remote turn-on tip polarity
+
3-12 volts for at least 100 mS
Y our Proceed dealer can help you take advantage of these design features to maximize your system's versatility.
3
AC MAINS FUSE One fast-blow fuse is located on the rear panel of the AMP If it should be. come necessary, replace the fuse with the same type only. Refer to the following table for replacement values. AMP 2 8 amp 4 amp AMP 3 12 amp 6 amp
100V to 120VAC 200V to 240VAC
Caution!
ALWAYS remove the AC cord before removing the fuse!
4
SPEAKER BINDING POSTS The Proceed AMP is equipped with gold-plated, high-current binding posts for output termination to a loudspeaker system. To take full advantage of the AMP's sonic quality, we recommend using high-quality speaker cable; see your Proceed dealer.
Caution!
NEVER connect the Proceed AMP output terminals to any device other than a loudspeaker. NEVER short-circuit the amplifier's output terminals. NEVER connect the left-channel output terminals to the rightchannel output terminals.
There are two recommended methods for connecting speaker cables to the Proceed AMP A high-quality spade lug or hook lug, soldered to the cable . (or crimped with extremely high pressure), is best.
14
Spade lug
Hook lug
Connect the left-channel + (positive or red) output post of the Proceed AMP to the + (positive or red) input terminal of the appropriate loudspeaker. Connect the left-channel (negative or black) output post of the AMP to the (negative or black) input terminal of the appropriate loudspeaker. Repeat this procedure for the remaining channel(s).
5
BALANCED AUDIO INPUTS Accepts right-channel and left-channel signals from preamplifiers with balanced outputs via high quality XLR connectors. The pin assignments of these XLR-type female input connectors are:
PUSH
21 3
Pin 1: Signal ground Pin 2: Signal + (non-inverting) Pin 3: Signal (inverting) Connector ground lug: chassis ground
These pin assignments are consistent with the standards adopted by the Audio Engineering Society Refer to the operating manual of your balanced. output preamplifier to verify that the pin assignments of its output connectors correspond to your Proceed AMP If not, wire the cables so that the ap. propriate output pin connects to the equivalent input pin. If you are planning to use balanced connections between your preamplifier and any particular channel of the AMP select the balanced input by sliding , the input select switch (see Item 6, below) toward the XLR input. Then connect the balanced outputs of your preamplifier to the corresponding balanced inputs on the AMP .
6
INPUT SELECT SWITCH This small switch is found between the balanced XLR input and the singleended RCA input on each channel of the AMP Use it to select which of the . The input select switch disables the unselected input in order to avoid any pickup of stray noise from an open input. It also causes the effective gain of that channel to be adjusted (either 23 dB balanced or 29 dB single-ended, to compensate for the 6 dB difference in signal level in these two connection standards). [. . . ] If your Proceed component must be serviced, please contact your dealer. Y our dealer will then decide whether the problem can be remedied locally, or whether to contact Madrigal for further service information or parts, or to obtain a Return Authorization. The Madrigal Technical Services Department works closely with your dealer to solve your service needs expediently.
Important!
Return authorization must be obtained from Madrigal's Technical Services Department BEFORE a unit is shipped for service.
It is extremely important that information about a problem be explicit and complete. A specific, comprehensive description of the problem helps your dealer and the Madrigal Technical Services Department locate and repair the difficulty as quickly as possible. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE PROCEED AMP2
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PROCEED AMP2 will begin.