User manual PROEL PLLEDSP

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual PROEL PLLEDSP. We hope that this PROEL PLLEDSP user guide will be useful to you.

Lastmanuals help download the user guide PROEL PLLEDSP.


Mode d'emploi PROEL PLLEDSP
Download
Manual abstract: user guide PROEL PLLEDSP

Detailed instructions for use are in the User's Guide.

[. . . ] This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: · Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. This marking shown on the product or its literature, indicates that it should not be disposed with other household wastes at the end of its working life. [. . . ] Reserves the right to change these specifications at any time without notice. Declines any liability for damages to objects or persons caused by lacks of maintenance, improper use, installation not performed with safety precautions and at the state of the art. ⷠCheck periodically that the slots for its proper ventilation and heating dissipation are not obstructed by dust, remove the dust using a dry brush or a compressed air gun. ⷠThe HPA450, HPA750 e HPD1000, HPD1500, HPD2000, HPD3000 amplifiers of Proel have been designed with CLASS I construction and must be connected always to a mains socket outlet with a proctetive earth connection (the third grounding prong). ⷠBefore connecting the product to the mains outlet make certain that the mains line voltage matches that shown on the rear of the product, a tolerance of up to ±10% is acceptable. ⷠTo disconnect these equipment from the AC Mains, disconnect the power supply cord plug from the AC receptacle. Thank you for having chosen a PROEL amplifier. The new HP-D series of professional power amplifiers is the result of a deep and meticulous stylistic and functional research merged into a series of high quality and reliable products, essential devices both in fixed installations and "on the road" applications. The powerful performances of the HP-D amplifiers satisfy an exceptionally wide range of amplification needs: live touring gigs, dance floors, sport venues, opera and drama theathres, worship venues, theme parks, cinema theathres, television studio and so on. D1500 with two indipendent channels, parallel or bridge configurable, fully made with switching technology with output stages in class-D shape. D3000 with four indipendent channels, configurable as two parallel or bridge amplifiers, fully made with switching technology with output stages in class-D shape. When this LED flashes reduce the input signal level of channel 1. When this LED flashes reduce the input signal level of channel 2. Yellow LED illuminates when the channel 1 is in protect mode for one of the following reasons: · The heatsink reaches a temperature above the normal working limit. ⷠThere is a short circuit at the amplifier output wires. Consequently the channel is muted until the reason of fault is removed. Yellow LED illuminates when the channel 2 is in protect mode. Yellow LED illuminates when both the channels are in bridge mode. NOTE: When the amplifier operates in BRIDGE mode SIGNAL, LIMIT and PROTECT LED indicators illuminate simultaneously, the signal is sent to both amplifiers from channel 1 input only and controlled by channel 1 level control only. Air cooling vent: always keep it clear of cables or other objects. Connect the power cord to an electrical outlet complying with the power supply specifications indicated on the apparatus. Be sure your amplifier is turned off before you plug the mains supply cord into an electrical outlet. [. . . ] Tip - hot ring - cold sleeve - ground *note: connect both cold and ground to make cable from balanced to unbalanced *nota: connettere insieme cold e ground per cavi da bilanciato a sbilanciato This is a short extraction of the wide assortment of cables available from PROEL, please visit our website at www. The above table is a short-form of some sound system examples composed of PROEL loudspeakers. These are a few portion of the speaker products in catalogue at the moment of printing. Make sure the mains AC outlet is live (check with a tester or a lamp). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PROEL PLLEDSP

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual PROEL PLLEDSP will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag