If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual QUANTUM ATL STACKLINK. We hope that this QUANTUM ATL STACKLINK user guide will be useful to you.
Lastmanuals help download the user guide QUANTUM ATL STACKLINK.
Manual abstract: user guide QUANTUM ATL STACKLINKINSTALLATION 09-2003
Detailed instructions for use are in the User's Guide.
[. . . ] ATL StackLinkTM
Installation Instructions
6421009-07 A01
Quantum ATL StackLinkTM Installation Instructions, 6421009-07 A01, September 2003, Made in USA. Quantum Corporation provides this publication "as is" without warranty of any kind, either express or implied, including but not limited to the implied warranties of merchantability or fitness for a particular purpose. Quantum Corporation may revise this publication from time to time without notice. COPYRIGHT STATEMENT Copyright 2003 by Quantum Corporation. [. . . ] Secure the rear shelf clamp to the shelf using two M4 countersink screws (PN YS42064). Repeat these steps to install a rear shelf clamp on the rear right rack rail. The left and right rear shelf clamps will be oriented differently from one another.
c d
Note:
Figure 26 Installing the Rear Shelf Clamps
ATL StackLinkTM Installation Instructions
37
Chapter 2 Installing the Rack Mount Shelves Installing the Shelves
8 Install the clamp strips (see figure 27): a Position a front shelf clamp (PN 215812) at the front of the front left rack rail, with the bottom of the clamp approximately 15. 5 inches (394 millimeters) above the bottom of the rack mount shelf. Caution: The top of the front shelf clamp must be no more than 22. 75 in. (580 mm) above the bottom of the rack mount shelf.
b c
Position a clamp strip (PN 217405) behind the front left rack rail, aligning it with the front shelf clamp. Insert a screw (PN YS42064) through the upper hole in the front shelf clamp, through the rack rail, and into the upper hole in the clamp strip. Insert a screw (PN YS42064) through the bottom hole in the front shelf clamp, through the rack rail, and into the bottom hole in the clamp strip. Repeat steps 8a through 8d to install the front shelf clamp and clamp strip on the right rack rail.
d
e
38
ATL StackLinkTM Installation Instructions
Chapter 2 Installing the Rack Mount Shelves Installing the Shelves
Figure 27 Installing the Clamp Strips
Clamp strip
Front shelf clamp
9 Tighten the nuts securing the shelves to the shelf extenders. Once you have installed all the rack mount shelves, proceed to the next chapter, Installing the Libraries on page 47. Note: The universal rack mount kit contains screws and nuts for many different types of rack. You will have many of these screws and nuts left over after installing the rack mount shelves and library.
ATL StackLinkTM Installation Instructions
39
Chapter 2 Installing the Rack Mount Shelves Installing the Shelves
Installing the Shelves in a Full U Position To install the rack mount shelves in a full U position: Note: The middle library in a 3-high ATL M2500 stack is mounted in a full U position.
2
1 From the six sizes of inserts provided in the rack mount kit, select the appropriate inserts for your rack. The insert part numbers are: · · · · · 213468 (for rails with 9 mm square holes) 213469 (for rails with 7 mm diameter unthreaded holes) 213471 (for rails with M6 threaded holes) 213473 (for rails with 10-32 UNF, 12-24 UNC, or M5 threaded holes) 213474 (for rails with 1/4 inch diameter unthreaded holes)
The heads of the inserts (not the threads) should fit into the holes in the rack rails smoothly and with very little play. 2 Screw three inserts into the front flange of each rack mount shelf in positions 1, 4, and 8 (counting from the bottom up, with 1 being the lowest hole) (see figure 22). Note: Some of the inserts have either no head or a head that has a smaller diameter than the thread; these need to be left protruding by about 1/8 in. The inserts with heads should be tightened fully.
40
ATL StackLinkTM Installation Instructions
Chapter 2 Installing the Rack Mount Shelves Installing the Shelves
Figure 28 Installing Inserts at the Front of the Shelves
8 4 1
8 4 1
3 Screw three inserts into the rear flange of each rack mount shelf in the positions shown in figure 29. If the shelves are oriented so the group of six holes is at the bottom and the group of four holes is at the top, the inserts go into holes 1, 5, and 10 (counting from the bottom up, with 1 being the lowest hole). Note: Some of the inserts have either no head or a head that has a smaller diameter than the thread; these need to be left protruding by about 1/8 in. The inserts with heads should be tightened fully.
Figure 29 Installing Inserts at the Rear of the Shelves
Group of 6 holes Group of 4 holes
1 5 10
Group of 4 holes 10 Group of 6 holes 5 1
ATL StackLinkTM Installation Instructions
41
Chapter 2 Installing the Rack Mount Shelves Installing the Shelves
4 Install the shelves (see figure 30): a b With the shelf slightly retracted, position the shelf in the rack at the desired mounting height. Expand the shelf so that the inserts on each end of the shelf protrude into the holes in the rack rails and hold the shelf in place. Repeat these steps to install the remaining shelf.
c
Figure 30 Installing the Shelves
Inserts protrude through the holes in the rails
5 Install the front shelf clamps (see figure 31): a Position a front shelf clamp (PN 215812) on the front left rack rail. The square holes in the front shelf clamp should be aligned with the upper two inserts in the front shelf flange. b c Secure the front shelf clamp to the rack rail using two M4 countersink screws (PN YS42064). [. . . ] Data elements are assigned consecutive addresses, starting at C0h. Import/export elements are assigned consecutive addresses, starting at B0h.
ATL StackLinkTM Installation Instructions
95
Appendix B SCSI Element Addressing Overview
Table 9 SCSI Element Addressing, Stand-alone ATL M1500
Address Element Drive 1 Drive 2 Left magazine Right magazine Fixed slot C0h-C9h CAh-D3h D4h DLT/SDLT 80h 81h C0h-CBh CCh-D7h D8h LTO Element Type Drive Drive Data Data Data
Table 10 SCSI Element Addressing, Stand-alone ATL M2500
Address DLT/SDLT Element Drive 1 Drive 2 Drive 3 Drive 4 Drive 5 Drive 6 Level 1 left magazine Level 1 right magazine Level 2 left magazine Level 2 right magazine 5-drive Library 80h 81h N/A* 82h 83h 84h C0h-C9h CAh-D3h D4h-DDh DEh-E7h 6-drive Library 80h 81h 82h 83h 84h 85h 5-drive Library 80h 81h N/A* 82h 83h 84h C0h-CBh CCh-D7h D8h-E3h E4h-EFh LTO 6-drive Library 80h 81h 82h 83h 84h 85h Element Type Drive Drive Drive Drive Drive Drive Data Data Data Data
96
ATL StackLinkTM Installation Instructions
Appendix B SCSI Element Addressing Overview
Address DLT/SDLT Element Level 3 left magazine Level 3 right magazine Level 4 left magazine Level 4 right magazine Level 1 fixed slot Level 2 fixed slot Level 3 fixed slot Level 4 fixed slot
LTO 5-drive Library 6-drive Library Element Type Data Data Data Data Data Data Data Data
5-drive Library
6-drive Library
E8h-F1h F2h-FBh FCh-105h 106h-10Fh 110h 111h 112h 113h
F0h-FBh FCh-107h 108h-113h 114h-11F 120h 121h 122h 123h
* In a 5-drive ATL M2500, the level 2 left drive bay is disabled, and therefore is not assigned a SCSI element address. In a 6-drive ATL M2500, the level 3 left magazine is not installed; however, it is still assigned the appropriate number of SCSI element addresses. In a 6-drive ATL M2500, the level 3 fixed slot is not installed; however, it is still assigned a SCSI element address.
ATL StackLinkTM Installation Instructions
97
Appendix B SCSI Element Addressing Option Settings and Their Effect on SCSI Element Addressing
Option Settings and Their Effect on SCSI Element Addressing
2
SCSI element addressing is affected by the settings of the Auto Clean and Import/Export options, which are set using the GUI Configuration menu. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE QUANTUM ATL STACKLINK
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.