If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual QUANTUM PX502 REPACKING INSTRUCTION 81-81453-02 A01. We hope that this QUANTUM PX502 REPACKING INSTRUCTION 81-81453-02 A01 user guide will be useful to you.
Lastmanuals help download the user guide QUANTUM PX502 REPACKING INSTRUCTION 81-81453-02 A01.
Manual abstract: user guide QUANTUM PX502 REPACKING INSTRUCTION 81-81453-02 A01
Detailed instructions for use are in the User's Guide.
[. . . ] Quantum PX502 Chassis Repacking Instructions
Introduction Removing the Library from the Rack Installing the Internal Shipping Restraints Packing the Library for Shipment
3 3 6 12
Document 81-81453-02 A01, January 2006
1
Quantum PX502 Chassis Repacking Instructions Document 81-81453-02 A01 January 2006
Made in the USA. Quantum Corporation provides this publication "as is" without warranty of any kind, either express or implied, including but not limited to the implied warranties of merchantability or fitness for a particular purpose. [. . . ] This procedure requires the packing materials originally sent with the library for proper shipment. If you do not have the library packing materials, contact Quantum customer support for replacement packaging (800) 284-5101.
0
Caution:
This procedure consists of the following steps: · · · Removing the Library from the Rack Installing the Internal Shipping Restraints Packing the Library for Shipment
Removing the Library from the Rack
To remove the PX502 library from the rack: Note: You must remove all tape cartridges from the library prior to parking the library robotics for shipment.
0
1 Using the OCP, open the front doors, remove both tape cartridge magazines, and remove any tape cartridges from the fixed bins or FlexLinkTM (refer to the Quantum PX500 Series User's Guide PN 81-81290 for information on OCP operation and bin locations). After removing the tape cartridge magazines and closing the doors, the library inventories all possible tape cartridge locations (magazines, fixed slots, Flexlink, and tape drives). 2 From the Library Operations screen on the OCP, select Park for Shipping. Note: If there are tape cartridges in the library, the system will NOT park the library robotics. You must remove all tape cartridges from the system prior to parking the library robotics.
Introduction
3
Quantum PX502 Chassis Repacking Instructions Document 81-81453-02 A01 January 2006
3 From the back of the library, disconnect all power, Ethernet, and SCSI cables from the library and note their locations for later reinstallation. Warning: This unit has more than one power supply cord. Disconnect all power supply cords before servicing to avoid electric shock.
4 To remove the library chassis from the rack (see figure 1): Note: Refer to the PX502 Quick Start Guide (PN 81-81292) for additional PX502 rack mount information.
a b c
Loosen the captive screws securing the tape drives to the chassis and remove the tape drive(s) from the back of the library. Loosen the captive screw securing the power supplies to the chassis and remove the power supplies from the back of the library. Remove PHILLIPS® screws securing each side of the chassis to the rack mounting rails and remove two Allen screws securing both clamps on the back of the library. At least two people are required to move the library chassis.
d
Warning:
4
Removing the Library from the Rack
Quantum PX502 Chassis Repacking Instructions Document 81-81453-02 A01 January 2006
Figure 1 Removing the PX502 Library
Tape drives
Power supplies
Right magazine
Removing the Library from the Rack
5
Quantum PX502 Chassis Repacking Instructions Document 81-81453-02 A01 January 2006
Installing the Internal Shipping Restraints
To ensure that the internal robotics within the library is not damaged, you must install the internal shipping restraints on the robotics. Caution: Failure to install the shipping restraints on the robotics may void your warranty.
0
To install the internal shipping restraints: 1 Place the library on a flat surface and remove the twelve PHILLIPS screws securing the FlexLinkTM cover and top cover plate to the library chassis (see figure 2): Note: If the bottom FlexLink cover has been removed, replace it before shipping the library back to Quantum.
Figure 2 Removing the Top Cover
Top cover
FlexLink cover
6
Installing the Internal Shipping Restraints
Quantum PX502 Chassis Repacking Instructions Document 81-81453-02 A01 January 2006
2 If the library is not operational and the Park for Shipping command was not executed, grasp the robotics and gently move it to the front of the library (see figure 3). [. . . ] Warning: At least two people are required to move the library chassis. Avoid putting the weight of the library chassis on the front bezel.
Caution:
Figure 8 Preparing the Library for Shipping
Accessories kit
Shipping materials
Library chassis
Front bezel Lift point Shipping materials
Shipping carton
12
Packing the Library for Shipment [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE QUANTUM PX502 REPACKING INSTRUCTION 81-81453-02 A01
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.