User manual QUANTUM SUPERLOADER 3 SOFTWARE INTERFACE GUIDE 81-81300-02 A01 SCSI
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual QUANTUM SUPERLOADER 3 SOFTWARE INTERFACE GUIDE 81-81300-02 A01 SCSI. We hope that this QUANTUM SUPERLOADER 3 SOFTWARE INTERFACE GUIDE 81-81300-02 A01 SCSI user guide will be useful to you.
Lastmanuals help download the user guide QUANTUM SUPERLOADER 3 SOFTWARE INTERFACE GUIDE 81-81300-02 A01 SCSI.
Manual abstract: user guide QUANTUM SUPERLOADER 3 SOFTWARE INTERFACE GUIDE 81-81300-02 A01 SCSI
Detailed instructions for use are in the User's Guide.
[. . . ] Quantum SuperLoader 3 Software Interface Guide, 81-81300-01 A01, January 2005. Quantum Corporation provides this publication "as is" without warranty of any kind, either express or implied, including but not limited to the implied warranties of merchantability or fitness for a particular purpose. Quantum Corporation may revise this publication from time to time without notice. COPYRIGHT STATEMENT © 2005 Quantum Corporation. [. . . ] The Sense Key is set to RECOVERED ERROR with an additional sense code of 5D 00 (TapeAlert Event). The SCSI command with CHECK CONDITION completes without error prior to the report of any exception condition, and does not need to be repeated.
CHECK CONDITION status on the next SCSI command (except INQUIRY and REQUEST SENSE commands)
reports information exception conditions by returning
58
SuperLoader 3 Software Interface Guide
Chapter 2 Media Changer Commands Mode Sense (6) / (10) Command (1Ah/ 5Ah)
Field Name
Description 06h
Only Report Informational Exception Condition on Request. The device server preserves informational
exception data. To access the data, a poll can be taken by issuing an unsolicited REQUEST SENSE command. The Sense Key is set to NO SENSE with an additional sense code of 5D 00 (TapeAlert Event). The additional sense code of 5D 00 for values 03h, 04h, and 06h signals that a TapeAlert event has occurred. Information about the event is stored in the TapeAlert Log Page. The setting of MRIE does not impact logging of events in the TapeAlert Log Page. Interval Timer Report Count/Test Flag Number Not supported.
Report Count or Test Flag Number. This field must be set to 0 unless the Test bit is set. When the Test bit is set, this field indicates that a test
condition to be generated as follows: Value 0 Result
Change no TapeAlert Flag but report an exception condition based on the setting of the MRIE field. Set the TapeAlert Flag indicated in the value and generate an exception condition based on the MRIE field. Clear the TapeAlert Flag in an equivalent manner to taking corrective action of indicated by the absolute number of the value. Set all TapeAlert Flags and generate and exception condition based on the setting of the MRIE field.
1 to 64
-1 to -64
32767
Element Address Assignment Page2
The element address assignment page is used to report element address assignments to the host. This page also defines the number of each type of element present. None of the fields in this page are changeable.
SuperLoader 3 Software Interface Guide
59
Chapter 2 Media Changer Commands Mode Sense (6) / (10) Command (1Ah/ 5Ah)
Figure 39 Element Address Assignment Page
Bit Byte 0 1
7 PS (0)
6 RSVD
5
4
3
2 Page Code (1Dh)
1
0
Parameter List Length (12h) (MSB)
2-3 (MSB) 4-5 (MSB) 6-7 (MSB) 8-9 (MSB) 10-11 (MSB) 12-13
First Medium Transport Element Address (LSB)
Number of Medium Transport Elements (LSB)
First Storage Element Address (LSB)
Number of Storage Elements (LSB)
First Import/Export Element Address (LSB)
Number of Import/Export Address (LSB)
60
SuperLoader 3 Software Interface Guide
Chapter 2 Media Changer Commands Mode Sense (6) / (10) Command (1Ah/ 5Ah)
Bit Byte
7 (MSB)
6
5
4
3
2
1
0
14-15 (MSB) 16-17
First Data Transfer Element Address (LSB)
Number of Data Transfer Elements (LSB)
18-19
Reserved
Table 28 Element Address Assignment Page
Field Name First Medium Transport Element Address Number of Medium Transport Elements First Storage Element Address Number of Storage Elements First Import/Export Element Address Number of Import/Export Elements
Description Identifies the address of the first medium transport element contained in the media changer. The SuperLoader 3 uses the default address of 0. Defines the total number of medium transport elements contained in the media changer. Identifies the address of the first medium storage element contained in the media changer. Defines the total number of storage elements contained in the media changer. There are 16 total, although since the magazines are removable, eight of them may be "inaccessible" at times. Identifies the address of the first import/export element that is accessible both by the medium transport device and also by an operator from outside the media changer. [. . . ] Specifies the length in bytes of the Identifier that shall be transferred from the application client to the device server. The maximum value for this field shall be 64 bytes. A parameter list length of zero indicates that no data shall be transferred, and that subsequent REPORT DEVICE IDENTIFIER commands shall return an Identifier length of zero. If the parameter list length exceeds 64 bytes, then the drive will return CHECK CONDITION status with the sense key set to ILLEGAL REQUEST and an additional sense code of INVALID
FIELD IN CDB.
The SET DEVICE IDENTIFIER parameter list contains the identifier to be set by the addressed logical unit.
Figure 80 Set Device Identifier Parameter List
Bit Byte 0-n
7
6
5
4
3 Identifier
2
1
0
Table 62 Set Device Identifier Parameter List
Field Identifier
Description Data to be returned by all subsequent REPORT DEVICE IDENTIFIER commands, until replaced by another valid SET DEVICE IDENTIFIER command.
142
SuperLoader 3 Software Interface Guide
Chapter 2 Media Changer Commands Test Unit Ready Command (00h)
Test Unit Ready Command (00h)
2
The TEST UNIT READY command checks the media changer to ensure that the unit is ready for commands involving cartridge movement. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE QUANTUM SUPERLOADER 3 SOFTWARE INTERFACE GUIDE 81-81300-02 A01 SCSI Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service. Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual QUANTUM SUPERLOADER 3 SOFTWARE INTERFACE GUIDE 81-81300-02 A01 SCSI will begin.