User manual RANE RA 30

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual RANE RA 30. We hope that this RANE RA 30 user guide will be useful to you.

Lastmanuals help download the user guide RANE RA 30.


Mode d'emploi RANE RA 30
Download

You may also download the following manuals related to this product:

   RANE RA 30 DATASHEET (470 ko)

Manual abstract: user guide RANE RA 30

Detailed instructions for use are in the User's Guide.

[. . . ] OPERATORS MANUAL RA 30 REALTIME ANALYZER METER -30 -27 -25 -24 -21 -18 -20 -15 -12 -15 -9 -6 -3 -10 +3 -5 +6 +9 +12 0 1 SCALE VU SPL 120 CAL WEIGHT METER PINK CAL LINE MIC IN OFF AUX MIC -12 +12 USE RANE MIC ONLY! 0 dB 3 6 dB NORMAL 100 80 dB A C RTA NOISE OL SIG RA 30 REALTIME ANALYZER RTA 25 31. 5 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1k 1. 25k 1. 6k 2k 2. 5k 3. 15k 4k 5k 6. 3k 8k 10k 12. 5k 16k 20k GAIN SOURCE CAL MIC Quick Start Since the RA 30 does RTA, SPL, and VU all in one, the first-time user can get a little lost. The real Quick Start is in the Step-by Step Instructions on page Manual-4. This will tell you how to set up the RA 30 for your application. In addition, read these few tips as a reminder of what you already know: USE MORE THAN ONE TEST MICROPHONE LOCATION. [. . . ] Levels above +3 dB on the VU scale switch to the red rows. If only the LEFT INPUT is connected, the RIGHT INPUT is internally connected for Mono operation. This results in the Left and Right displays tracking each other. The VU meter incorporates an instantaneous peak hold function with a 2 second hold time. The peak value is displayed with a single LED for each channel (transient peaks can often be 6 to 20 dB above the rms average value). If the held peak value is greater than +12 dB on the VU scale, the 9 dB CREST FACTOR +12 dB LEDs stay illuminated. In this case, the Input gain can be decreased until the peak value is not "stuck" at +12 dB. For a calibrated peak measurement, the input gain can be set to minimum which sets the 0 dB mark on the VU scale to +16 dBu. Example: With the GAIN set to +4 dBu, the display shows a nominal signal with a 9 dB crest factor. The Peak Hold function is enabled or disabled by pressing the NORMAL button while in VU mode. +3 -5 +6 +9 +12 0 SCALE VU SPL 1 120 100 80 WEIGHT METER PINK 3 NORMAL 6 dB dB A C RTA NOISE 2. 5k 3. 15k 4k 5k 6. 3k 8k 10k 12. 5k 16k 20k II. Connect the Rane MIC 2 to the CAL MIC Input on the front of the unit. Set the GAIN control on the front of the unit to the center detent. Select the METER mode by pressing the METER/RTA button so the METER LED illuminates. Select the desired A- or C-weighting by pressing the WEIGHT button (see WEIGHTING FILTERS, next page). Read the SPL level from the display using the SPL scale (second row from the top). Example: Reading the middle row of green LEDS from left to right, the right-most illuminated LED corresponds to -7 dB, the 100 dB LED is illuminated, and A-weighting was selected (indicated by the A LED), the A-weighted SPL is 93 dBA. +3 -5 +6 +9 +12 0 SCALE VU SPL METER PINK 1 120 100 80 WEIGHT 3 NORMAL 6 dB 2. 5k 3. 15k 4k 5k 6. 3k 8k 10k 12. 5k 16k 20k dB A C RTA NOISE +0 -10 -20 dBr -30 -40 -50 -60 20 +0 -10 -20 dBr -30 -40 -50 -60 20 RTA Scales >+2 dB +1-2 dB ±1 dB ­1-2 dB 50 100 200 500 Hz 1k 2k 5k 10k 20k ±1 dB 50 100 200 500 Hz 1k 2k 5k 10k 20k <­2 dB SPL mode A-Weighting Curve SPL mode C-Weighting Curve >+6 dB +3-6 dB ±3 dB ­3-6 dB <­6 dB >+12 dB +6-12 dB ±6 dB ­6-12 dB <­12 dB III. Select the RTA mode by pressing the METER/RTA button so the RTA LED illuminates. Operates on the Input selected by the SOURCE switch: CAL MIC, LINE IN, or AUX MIC. Note: When LINE IN is selected, the RTA operates on the mono sum of the Left and Right Inputs. Select the scale by pressing the SCALE button, which sets the display in dB relative to the center row. Press the NORMAL button to set the maximum band level to 0 dB. Set the desired SCALE and adjust the GAIN control for a centered display. [. . . ] Feedback induced by specific stage mic/monitor speaker coupling can also be attenuated by leaving the stage mic turned up and running up the pink noise level through the monitor speaker until feedback occurs. Attenuate each feedback frequency, as indicated by the analyzer display, until the mic/monitor combination feeds back at two or more frequencies simultaneously. Usually the final EQ setting will be a compromise between a good monitor sound that doesn't get as loud, or a not-so-good monitor sound that gets louder before feedback. Place the Rane microphone at eye level of the performer and about six inches off to one side of the stage microphone, in line of sight to the monitor speaker. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE RANE RA 30

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual RANE RA 30 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag