User manual RAYMARINE RAYSTAR 114 DIFFERENTIAL GPS SENSOR

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual RAYMARINE RAYSTAR 114 DIFFERENTIAL GPS SENSOR. We hope that this RAYMARINE RAYSTAR 114 DIFFERENTIAL GPS SENSOR user guide will be useful to you.

Lastmanuals help download the user guide RAYMARINE RAYSTAR 114 DIFFERENTIAL GPS SENSOR.


Mode d'emploi RAYMARINE RAYSTAR 114 DIFFERENTIAL GPS SENSOR
Download
Manual abstract: user guide RAYMARINE RAYSTAR 114 DIFFERENTIAL GPS SENSOR

Detailed instructions for use are in the User's Guide.

[. . . ] Voltage drops below 10. 7V in the power supply to our products can cause the equipment to reset. This will not damage the equipment, but may cause the loss of some information and can change the operating mode. · Genuine Raytheon cables should be used at all times. Cutting and rejoining these cables can compromise EMC performance and so should be avoided unless doing so is detailed in the installation manual. 2 Raystar 114 Check Before Going to Sea · Always check the installation before going to sea to make sure that it is not affected by radio transmissions, engine starting etc. [. . . ] A Surface mounting and rail mounting kit is supplied. When mounting the receiver unit flush to a deck surface avoid areas where the unit will be walked on or where it may become a tripping hazard. CAUTION Care should be taken that the unit is sited to avoid personal injury caused by falling on the aerial. Note: Mounting on the mast of a sailboat is not recommended. Grounding the System For optimum operation the unit should be connected to the ships ground system. . You can ground the unit using one of the following three methods: 1. A 24 AWG wire can be connected via the screw connection found in the base of the unit, as shown in the following illustration. Grounding screw D4435-1 2. The cable screen can be connected to ground. Note: This will require the insulation to be cut back to obtain access to the screen. A conducting pole mount, which is connected to ground, can be screwed into the base of the unit. 8 Raystar 114 Mounting The Raystar 114 can be mounted on a pole. Alternatively, you can use the kit supplied to surface mount or rail mount the unit. The aluminium base of the Raystar 114 has received a chromation treatment which adds toughness, resistance to wear and tear, and resistance to corrosion of the assembly. The base of the sensor has a slot cut into it to feed the pre-wired cable externally of the mount. If the cable is fed through this slot, it should be secured with a cable tie to the base of the unit. If you prefer to feed the cable through the mount, it will be necessary to cut the cable as the connector will not feed-through. You should reconnect the cable using a connector block, refer to the Connections section for cable details. The cable assembly supplied is 15m (49ft 3in) in length with a moulded 6-pin connector fitted at the receiver end. The cable should be run as directly as possible to the navigation console or to the external navigation device. The cable can be cut as necessary to the required length, or coiled and stored out of the way. Refer to the Connections section for cable details . Pole Mount The Raystar 114 can be mounted on a pole with an industry standard 1" 14 TPI thread as follows: 1. Screw the Raystar 114 unit onto the mount by hand, paying attention to avoid curling, tight loops, and kinking of the cable. When the unit is fully threaded on the mount use a proper sized spanner and protective cloth to grip the base and tighten the unit to the mount. [. . . ] When/ or if repairs are necessary, these products must be forwarded to a Raytheon Marine Company facility or an authorized dealer at owner's expense will be returned via surface carrier at no cost to the owner. Travel costs other than auto mileage, tolls and two (2) hours travel time, are specifically excluded on all products. Travel costs which are excluded from the coverage of this Warranty include but are not limited to: taxi, launch fees, aircraft rental, subsistence, customs, shipping and communication charges etc. . Travel costs, mileage and time, in excess to that allowed must have prior approval in writing. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE RAYMARINE RAYSTAR 114 DIFFERENTIAL GPS SENSOR

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual RAYMARINE RAYSTAR 114 DIFFERENTIAL GPS SENSOR will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag