If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual RAYMARINE ST80 REMOTE KEYPAD. We hope that this RAYMARINE ST80 REMOTE KEYPAD user guide will be useful to you.
Lastmanuals help download the user guide RAYMARINE ST80 REMOTE KEYPAD.
Manual abstract: user guide RAYMARINE ST80 REMOTE KEYPAD
Detailed instructions for use are in the User's Guide.
[. . . ] SeaTalk Remote Keypad Owner's Handbook
Document number: 81073_5 Date: 1February 2003
© Copyright Raymarine Limited 2003
SeaTalk Remote Keypad Owner's Handbook
i
Contents
Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Chapter 1: Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1. 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 EMC conformance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] When necessary, replace and secure damaged cables.
Assistance
For advice or further information regarding this product, please contact the Raymarine Product Support Department or your own National Distributor.
2. 2 Fault finding
All Raymarine products are subjected to a comprehensive test procedure prior to packing and shipping. In the unlikely event that a fault does occur with your Remote Keypad, use the following check list to help identify and rectify the problem.
6
SeaTalk Remote Keypad Owner's Handbook
Keypad does not operate · Make sure the cable connecting the keypad to SeaTalk is connected properly. · Make sure the cable is not damaged. Instruments do not operate in a logical sequence · Instruments and keypad are not grouped. Refer to Chapter 4, Setup chapter for grouping details. All instruments operate at the same time · Instruments are not grouped. Refer to Chapter 4, Setup chapter for grouping details. Instruments cannot be remotely controlled · Not in a keypad group. Refer to Chapter 4, Setup chapter for grouping details.
Chapter 3: Installation
7
Chapter 3 Installation
3. 1 Planning your installation
Before installing your SeaTalk Remote Keypad, spend some time considering the best position. It should be fitted in a position which gives optimum accessibility while at the same time satisfying the EMC installation guidelines and the other Site requirements, described below. Ensure that you have all the necessary components, templates and tools for the job.
EMC installation guidelines
All Raymarine equipment and accessories are designed to the best industry standards for use in the leisure marine environment. Their design and manufacture conforms to the appropriate Electromagnetic Compatibility (EMC) standards, but correct installation is required to ensure that performance is not compromised. Although every effort has been taken to ensure that they will perform under all conditions, it is important to understand what factors could affect the operation of the product. To minimise the risk of operating problems: · All Raymarine equipment and cables connected to it should be: · At least 1 m (3 feet) from any equipment transmitting or cables carrying radio signals, e. g. In the case of SSB radios, the distance should be increased to 2 m (7 ft). · More than 2 m (7 ft) from the path of a radar beam. A radar beam can normally be assumed to spread 20 degrees above and below the radiating element. · The equipment should be supplied from a different battery than the one used for engine start. Voltage drops below 10 V in the power supply to our products can cause the equipment to reset. This will not damage the equipment, but will cause the loss of some information and can change the operating mode. · Raymarine specified cables should be used at all times. Cutting and rejoining these cables can compromise EMC performance and so should be avoided unless doing so is detailed in the installation manual.
8
SeaTalk Remote Keypad Owner's Handbook
· If a suppression ferrite is attached to a cable, this ferrite should not be removed. [. . . ] Repeat the procedure in steps 3 and 4 until all instruments in the group have been identified. Note: If you have more than eight standard instruments, a second group, operated by another Remote Keypad, must be created. The identification code for additional Keypads and instruments would for example, be B1, B2 etc. Assign a Remote Keypad to the required group as follows: (a) Use the or key to select any instrument in the required group. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE RAYMARINE ST80 REMOTE KEYPAD Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service. Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual RAYMARINE ST80 REMOTE KEYPAD will begin.