User manual RENKUS-HEINZ ICONYX IC LIVE ICL-FR-DUAL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual RENKUS-HEINZ ICONYX IC LIVE ICL-FR-DUAL. We hope that this RENKUS-HEINZ ICONYX IC LIVE ICL-FR-DUAL user guide will be useful to you.

Lastmanuals help download the user guide RENKUS-HEINZ ICONYX IC LIVE ICL-FR-DUAL.


Mode d'emploi RENKUS-HEINZ ICONYX IC LIVE ICL-FR-DUAL
Download
Manual abstract: user guide RENKUS-HEINZ ICONYX IC LIVE ICL-FR-DUAL

Detailed instructions for use are in the User's Guide.

[. . . ] Owners Manual Digitally Steerable Line Array Loudspeaker Systems IC Live ICL-R ICL-FR & ICL-FR-DUAL USERS MANUAL Assembly & Installation Instructions IC Live Users Manual. Models: ICL-R, ICL-FR & ICL-FR-DUAL IMPORTANT SAFETY INSTRUCTIONS 1. The apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases, shall be placed on it. Install in accordance with the manufacturer's instructions. [. . . ] The graphic below shows a typical setup for a small room (50 feet deep) with the bottom of the array placed 6. 46 feet above floor level, approximately the height of an array mounted on a subwoofer sitting on a stage or at altar level. Note that a single ICL-F array was selected and an opening angle of 30o chosen. A center frequency of 3150 Hz was also selected for the simulation as it better depicts what the listeners will be hearing than the lower 1000 Hz center frequency we used in previous simulations. IC Live Users Manual. Models: ICL-R, ICL-FR & ICL-FR-DUAL The next graphic shows a much larger room, 100 feet deep instead of 50 feet. Not that the beam opening was narrowed to 20o to obtain a longer throw. Still the level is starting to fall off at the rear of the room. It might be wise to consider using a "Dual" module ICL-F-DUAL array. CONNECT MODE 30 The next graphic shows an even larger room, one with a 125 foot throw. Note that the more powerful ICL-FR-DUAL array was chosen and the opening angle reduced to 15o. IC Live Users Manual. Models: ICL-R, ICL-FR & ICL-FR-DUAL At this point the changes you have made in beam steering have not been sent to the associated loudspeaker or stored as a Preset. IC Live arrays can store up to 10 different configurations as Presets in the array's DSP memory. For example, you might optimize one configuration for small events on the main audience area and another for larger occasions when a balcony is used. The Presets include the beam steering data, as well as gain, EQ , compression, etc. Once the configurations are stored it is easy to switch between them. They can be recalled from either the rear of the array, from the controlling computer or, if one is provided a wall mounted rotary switch. A digital readout on the rear of the array displays the selected Preset. They are labeled 10 to 19 for single arrays and 20 to 29 for Dual arrays. Presets 10 and 20 are claimed by the factory for field test purposes; they send an equal signal to all the drivers making it easy to check them by ear for proper operation. Portable IC Live models are also supplied with a number of preset configurations set at the factory for typical setups. IC Live users should refer to their Operators manual for details on these presets. If you attempt to leave Beam Steering without saving the setup information, the prompt shown here will remind you of the need to save it, if you want to keep it. Note that presets can not be saved to an array in the virtual world. The following applies only when an array is is connected. [. . . ] To fix, close RHAON (and, if running, CobraNet Discovery) and bring up the Windows Task Manager (Ctrl-AltDelete). Under the tab "Processes", look for `PACNDISCO. EXE' and `PASSBRIDGE. EXE' (Windows may shorten the name and add `~1'). Select them and click "End Process". Proceed to re-open RHAON and/or CobraNet Discovery. Switch-Related Issues Note that unmanaged switches have no configuration. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE RENKUS-HEINZ ICONYX IC LIVE ICL-FR-DUAL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual RENKUS-HEINZ ICONYX IC LIVE ICL-FR-DUAL will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag