User manual RENKUS-HEINZ RH-1 DYNA-GARD

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual RENKUS-HEINZ RH-1 DYNA-GARD. We hope that this RENKUS-HEINZ RH-1 DYNA-GARD user guide will be useful to you.

Lastmanuals help download the user guide RENKUS-HEINZ RH-1 DYNA-GARD.


Mode d'emploi RENKUS-HEINZ RH-1 DYNA-GARD
Download
Manual abstract: user guide RENKUS-HEINZ RH-1 DYNA-GARD

Detailed instructions for use are in the User's Guide.

[. . . ] Caution: RH-1 DYNA-GARD modules are configured for use with a particular loudspeaker and C22 modules are customized for use with particular loudspeakers by the proper setting of several control switches. Make sure the module is set up to operate with your loudspeaker(s) before connecting the loudspeaker(s) and turning on the system. RH-1 DYNA-GARD Controller Module Channel 1 & 2 controller outputs (processed signals) to additional power amplifiers. INPUT PIN 1 = GND PIN 2 = + PIN 3 = SUB/LF OUT FR/HF RENKUS-HEINZ MADE IN USA Input MODEL RH-1 DYNA-GARD IRVINE, CA - U. S. A. MODEL P-2400 cc 2 BRIDGE POWER CONSUMPTION : 920 W SERIAL N 1 OUTPUTS RISK OF ELECTRICAL SHOCK DO NOT OPEN T O REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE TO REDUCE THE RISK OF ELECTRICAL SHOCK DO NOR REMOVE COVER (OR BACK) NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL MANUFACTURED IN EEC 117 V ~ T 10 A 250 V STEREO 4 OHM MIN. /CH. BRIDGED MONO 8 OHM MIN. Sub/LF amplifier output to associated subwoofers or to the low frequency section of active 2-way loudspeakers. FR/HF amplifer output to associated full-range loudspeakers or to the high frequency section of active 2-way loudspeakers. The RH-1 DYNA-GARD loudspeaker controller module shown above is a single input input, dual output module used in single channel (mono) systems having either active 2-way loudspeakers (or 3-way loudspeakers set up for bi-amp operation) or in systems having full-range (passive) loudspeakers and subs (refer to the block diagrams show below. ) It provides crossover circuitry, protection against overload damage, and frequency response smoothing. [. . . ] 3 RH-1 DYNA-GARD · C22 · L20 OPERATION MANUAL RH-1 DYNA-GARD Controller Module (continued) 1 2 3 MODEL RH-1 DYNA-GARD INPUT PIN 1 = GND PIN 2 = + PIN 3 = - SUB/LF OUT FR/HF RENKUS-HEINZ MADE IN USA cc Input Connections 1. Audio Input Connector Female 3-pin XLR type input connector. We recommend the use of pin 2 as "hot" and pin 3 as "neutral". When the amplifier is connected to a balanced source, the shield may either be lifted or connected at the source end. The choice should be made on the basis of minimum hum. With an unbalanced source, connect the signal to pin 2 and source ground to pin 3 (connecting the signal to pin 3 is not rcommended as this will cause a 180 phase invervion at the amplifier outputs). Note: Improper operation results when only pin 2 or only pin 3 and pin 1 (ground) are used for an unbalanced input. Output Connections 2 & 3. SUB/LF and FR/HF "Output" Connectors Male 3-pin XLR type controller output connectors for the SUB/LF and FR/HF channels; used to drive additional amplifiers. Note: When the RH-1 DYNA-GARD's controller outputs are used to drive additional amplifiers, it is imperative that the amplifier's level controls be set at the same or a higher level than the level of the amplifiers being driven. Otherwise, the protection feature is lost for the other amplifiers. C22 Controller Module Channel 1 & 2 controller outputs (processed signals) to additional power amplifiers. 2" In MODEL Channel 1 & 2 "Looping" (unprocessed signals) or HPF (high pass filter) controller outputs (processed signals) to additional power amplifiers. CH 2 OUTPUTS CH 2 INPUT PIN 1 = GND PIN 2 = + PIN 3 = CH 1 INPUT CH 1 OUTPUTS RENKUS-HEINZ MADE IN USA C22 IRVINE, CA - U. S. A. MODEL P-2400 cc 117 V ~ PROCESSED LOOPING / HPF GROUND LOOPING / HPF PROCESSED POWER CONSUMPTION : 920 W SERIAL N 2 BRIDGE 1 OUTPUTS RISK OF ELECTRICAL SHOCK DO NOT OPEN T O REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE TO REDUCE THE RISK OF ELECTRICAL SHOCK DO NOR REMOVE COVER (OR BACK) NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL MANUFACTURED IN EEC T 10 A 250 V STEREO 4 OHM MIN. /CH. The HPF setting is used to deliver a band-limited signal to an additional amplifier for "non-overlap" operation (refer to the system wiring diagram on the previous page for further information. ) The Stereo/Bridging Jumper plug is used to "bridge" the two output channels together to provide a single output with twice the power capabilities of a single channel. Note that the Jumper Plug is located under the right PK22-xxx kit, which must be removed (unplugged) to gain access to the Jumper Plug. Output Connections Input Connections Ground Lift Switch Selector Switches 5 RH-1 DYNA-GARD · C22 · L20 OPERATION MANUAL C22 Controller Module (continued) Looping/HPF Selector Switches Filtered sw 2 PK22-xxx Kit sw 1 sw 1 PK22-xxx Kit Filtered sw 2 Stereo Bridged Stereo/Bridged Jumper Plug sw 3 sw 3 C22 Controller Module Physical Layout C22 Setup Switches The switches identified as sw 1, sw 2 and sw 3 are used to configure the C22 for specific loudspeakers. The proper settings for these switches are shown in the enclosed charts. L20 Limiter Module Ch. 1 Input Channel 1 & 2 looping outputs (unprocessed signals) to additional power amplifiers, CH 2 INPUT HPF SELECT MODEL L20 CH 2 OUTPUT PIN 1 = GND PIN 2 = + PIN 3 = - CH 1 INPUT HPF SELECT CH 1 OUTPUT IRVINE, CA - U. S. A. STEREO GROUND MODEL P-2400 POWER CONSUMPTION : 920 W SERIAL N LIMIT SET LIMIT SET PARALLEL BRIDGE X 2 BRIDGE 1 OUTPUTS RISK OF ELECTRICAL SHOCK DO NOT OPEN T O REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE TO REDUCE THE RISK OF ELECTRICAL SHOCK DO NOR REMOVE COVER (OR BACK) NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL MANUFACTURED IN EEC 117 V ~ T 10 A 250 V STEREO 4 OHM MIN. /CH. BRIDGED MONO 8 OHM MIN. Channel 1 Channel 2 Channel 1 and 2 outputs to loudspeakers. The L20 is a dual-channel limiter module. It is not loudspeaker specific and is provided with user adjustable limit and HPF (high pass filter) controls (refer to drawing on next page). It is used to provide limiting on both amplifier channels (loudspeaker protection) plus low frequency rolloff. "Looping" Audio Output Connectors These male 3-pin XLR type connectors are wired in parallel with the input connectors and provide unprocessed "looping" Channels 1 and 2 outputs. They allow "looping" through to additional amplifiers. HPF Selector Switches Three position switches allow the Channel 1 and 2 low frequency rolloff points to be set at either 30 Hz, 60 Hz or 100 Hz to protect small loudspeakers from over excursion damage. Looping Outputs HPF Selectors 6 RH-1 DYNA-GARD · C22 · L20 OPERATION MANUAL L20 Controller Module (continued) 1 2 3 4 5 6 MODEL L20 OUTPUT CH 2 60Hz INPUT HP FILTER 100Hz 30Hz LIMIT 100 200 350 PIN 1 = GND PIN 2 = + PIN 3 = - INPUT CH 1 OUTPUT HP FILTER 100Hz RENKUS-HEINZ MADE IN USA 60Hz 30Hz LIMIT 100 200 350 (400) (800) (1400) BRIDGE STEREO GROUND (400) (800) (1400) BRIDGE PARALLEL BRIDGE X 7 8 9 10 3 & 4. Audio Input Connectors Female 3-pin XLR type input connectors for Channels 1 and 2. [. . . ] Limit Set Switches Three position switches allow the Channel 1 and 2 maximum output levels to be set at either 100, 200 or 350 watts into 8 ohms (400, 800 or 1400 watts in bridge mode). Stereo - Parallel - Bridge Output Mode Selector The Output Mode Selector allows the amplifer to be operated in 3 different output modes. In the Stereo mode, the two channels operate independently, just as they do in a stereo amplifier: signals fed into the two amplifier inputs are amplified separately and delivered in phase to outputs 1 & 2. The output levels are controlled separately by the front panel mounted attenuators. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE RENKUS-HEINZ RH-1 DYNA-GARD

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual RENKUS-HEINZ RH-1 DYNA-GARD will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag