If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual REVOX RECONNECT M203. We hope that this REVOX RECONNECT M203 user guide will be useful to you.
Lastmanuals help download the user guide REVOX RECONNECT M203.
Manual abstract: user guide REVOX RECONNECT M203EIB & KNX BRIDGE
Detailed instructions for use are in the User's Guide.
[. . . ] The EIB software is not copy protected.
Installation
The M203 interface can be installed easily and quickly. There are two types of fixing available.
1) The four outside fixing holes are used for a permanent installation. 2) Revox recommends using the two slots on the side for a variable installation.
Connection plan
Connection to the M51 Connection to further external M51- Interfaces IR-/ wall-mounted remote control M204/ M218 RS232 seriell interface
Slotted hole
Serial interface activity display Setup button
3
M203 EIB/ KNX
Re:connect
Connection: M203 with M51 Socket: M51 LINK IN The M203 interface is connected to the M51 LINK IN socket on the back of the M51 with the telephone cable supplied. If you want to use a different cable for some reason, you should use only a noncrossed, 4-core telephone cable with an RJ11 plug (6P4C modular). [. . . ] An M218 wall-mounted remote control, with integrated IR receiver, can be connected instead of the M204 IR receiver.
6
M203 EIB/ KNX
Re:connect
Connection example EIB part
7
M203 EIB/ KNX
Re:connect
Connection example Revox MR part The EIB wall-mounted keypad units are installed in the required (additional) rooms, which make up the Revox Multiroom System. Each Additional room amplifier can be addressed over the M203 EIB-Bridge. Additionally, the Additional room amplifier can be integrated into a scene control.
8
M203 EIB/ KNX
Re:connect
Setup key
Using the Setup key, you can call the M203 menu, which appears in the M51 display.
Slot Selection
If a second M203 (M200) is connected to the M51 Link output, a different address must be assigned through the slot selection so that both M203s don't occupy the same slot address. In the case of a double assignment, neither of the two M203s would be shown in the M51 Version list. Slot addresse: #11 or #12
Using the Softkeys you can get to pages #1 and #2
Important: Only one M203 may be connected to the M51 Link for the address selection. You should separate the one M203 from the M51 Link while assigning the address to the other. If the addresses are correctly set, both M203s (M200) will appear in the M51 version list. You will find further information on this topic in the M51 manual in the Introduction chapter under the Version function.
9
M203 EIB/ KNX
Re:connect
Setup #2 - EIB Adresse
The installer can assign different main group addresses, in the range from 0 to 15, when programming the EIB bus coupler units (BCU) for the Revox Multiroom controller keypads. The definition of the middle (Y) and lower (Z) group addresses is handled by the Revox protocol. An individual group address YZ results from each combination of (Multiroom) zone, room and function. The easiest way of calculating the individual YZ group addresses is to use the Excel Configuration guide that can be downloaded from the Revox Homepage, ww. revox. de / Download/ Re:connect. You can see the room and zone assignments of a maximum configuration Revox Multiroom System on page 13. The address for rooms 1 8 in the corresponding zones is set through DIL switches on the M219 Additional room amplifier. You will find a description in the M219 Additional room amplifier Operating manual. Another convenient way of determining the room addresses is the Revox Multiroom planner PC software, which can be downloaded free of charge from the Revox homepage.
All keypads and/or their BCUs, which are used for controlling the Revox Multiroom System must have the same main group address (X). lighting or heating, must be assigned a different main group address than the Revox EIB-Bridge. Otherwise, wrong interpretations may result. The main group address used (X) is set on page #2. Setting is done using the two softkeys Address +. You do not have to confirm the address setting. Main address 5 was used in the above example. In this case, all BCUs and/or their keypad units, which are used to control the Revox Multiroom System must also have the main group address 5 so that the controls work correctly.
10
M203 EIB/ KNX
Re:connect
Important information · Parallel operation The Revox M217 Wallmounted display and/or the M218 wall-mounted control panel can be installed parallel to an EIB Controller. [. . . ] On the other hand, installing M218 Wall-mounted keypads or M204 IR receivers in parallel to the EIB System does not reduce the number of rooms with a zone. The following Operating manuals contain a detailed description of the Revox Multiroom System. · Multiroom Module (MK 1 3) · M219 Additional room amp. · M217 Wall-mounted display
13
M203 EIB/ KNX
Re:connect
Technical data
IR-LINK: + IN Dimensions: Weight: Power consumption: Max. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE REVOX RECONNECT M203
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.