User manual REVOX RECONNECT M200 DOMOTIC INTERFACE
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual REVOX RECONNECT M200. We hope that this REVOX RECONNECT M200 user guide will be useful to you.
Lastmanuals help download the user guide REVOX RECONNECT M200.
You may also download the following manuals related to this product:
REVOX RECONNECT M200 DOMOTIC INTERFACE (1054 ko)
Manual abstract: user guide REVOX RECONNECT M200DOMOTIC INTERFACE
Detailed instructions for use are in the User's Guide.
[. . . ] These could, for example, be the M201 IR interface or simply an additional M200. You should use only a noncrossed, 4-core telephone cable with an RJ11 plug (6P4C modular) for this connection.
Connection: M200 with serial interface Socket: RS 232 The RS232 interface can be used to connect the Domotic interface to other devices that also have a serial interface. These devices however, must have a special REVOX protocol and for that reason, are only available from REVOX and its partners. [. . . ] The Options menu is called by pressing the Setup key on the Domotic interface. Using the softkeys you can access page #2, which gives the following display on the M 5 1 :
Function
Remote The relays are controlled through the remote control. This function is only available in the M51 is switched on. Power On/Off If the M51 is switched on, the relay is energised. In standby mode, the relay is in idle state. Video On/Off The relay is energised if the DVD source is selected. This function can be used to roll out a projector screen or to close window blinds. 2
The required option can be selected from an option loop:
Remote Open Close Power On/Off Video On/Off
Please note
The switching voltage may not exceed 42 volts. Further information can be found in the Technical data chapter.
7
M200 Interface
M Series
Connection: M200 Voltage ramp Socket CONTROL: OUTPUT Using the OUTPUT, you can control the output voltage with the remote control, giving a variable voltage between 0 and 10 volts. This voltage ramp could be used, for example, to set the dimmer control of a lighting system to a desired level. Please ensure that you use the correct polarity when setting up as otherwise you might damage your equipment.
Connection: M200 with IR controller Socket CONTROL: IR- LINK The connection to an IR receiver or a wall-mounted remote control is done through the 3-pin, screw-fixable Phoenix plug connection.
REVOX recommends the use of a 2-core screened cable (microphone cable), where the screening is used as ground. This cable may be a maximum of 30 metres in length.
Please ensure that you use the correct polarity when setting up as otherwise you might damage your equipment. 20V (DC) IN IR Signal Ground The maximum number of IR receivers that can be switched in parallel per M200 is 5
The voltage (+ , - ) on the IP LINK can be used to control the CONTROL: INPUT A B inputs.
8
M200 Interface
M Series
Setup key
Using the Setup key, you can call the Domotic menu, which appears in the M51 display.
Setup #1 Input A/B
Menu: Voltage input Display: Control Input A/B Please refer to page 5, Control Input A/B chapter for a description.
Using the Softkeys you can get to pages #1 - #4
Setup #2 Relays A/B
Menu: Voltage input Display: Func. Relays A/B Please refer to page 7, Relay A B chapter for a description.
9
M200 Interface
M Series
Setup #3 - Address
Setup #3- Source
Menu: Address Display: Remote Address Selection of the addresses that the M200 interface accepts for communication. Address
Light (30) Local (19) Both (30+19)
Menu: Source Display: Remote Source Selection of the (IR) sources that the M200 interface accepts as data suppliers.
This M-200 only Accepts only sources that are directly connected to the M200's IR Link, e. g. . MR204 or M218 wallmounted remote control. All Receivers All sources are accepted as data suppliers, e. g. also a M51 or an additional M200 interface.
Sender
SRC 2000 remote control Wall-mounted remote control Combination
10
M200 Interface
M Series
Setup #4 - Slot
Setup #4 - Port
Menu: Slot address Display: Slot Address If an additional M200 or an other external M series interface is connected, different addresses should be given through the slot selection. [. . . ] no. : 642 000 2001 Not available with Model E642 from Ser. no. : 642 000 2001
2
13
M200 Interface
M Series
Setup #5 Reset
If you want to return the settings in Setup #5 menu to the factory settings, simply press and hold the Disable softkey until the Setup- #1 page appears again.
Auto Standby
The Auto Standby function enables the Plasma TV to remain switched on, even in the case of selected audio sources that do not activate a video input at the Plasma TV, e. g. the M51 radio tuner.
This resets all input assignments and restores the factory settings.
Auto Standby: ON The Plasma TV switches itself off automatically as soon as an audio source is selected, which either cannot activate a Plasma input, e. g. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE REVOX RECONNECT M200
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual REVOX RECONNECT M200 will begin.