User manual REX RLB5M

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual REX RLB5M. We hope that this REX RLB5M user guide will be useful to you.

Lastmanuals help download the user guide REX RLB5M.


Mode d'emploi REX RLB5M
Download
Manual abstract: user guide REX RLB5M

Detailed instructions for use are in the User's Guide.

[. . . ] Por este motivo recomendamos dirigirse siempre al Concesionario que ha efectuado la venta o a nuestro Centro de Asistencia más cercano, especificando el tipo de inconveniente y el modelo del aparato que se posee. Hay que recordar, además, que los recambios originales se encuentran sólo en nuestros Centros de Asistencia Técnica. Estas instrucciones son válidas solamente para los países de destino cuyos símbolos figuran en la tapa y en el aparato. ES Esta aparelhagem, antes de sair da fábrica, foi submetida a provas e regulações por pessoal especializado, de modo a fornecer as melhores resultados de funcionamenPT to. Qualquer reparação ou regulação que se torne necessária deve ser feita com o máximo cuidado e atenção. [. . . ] Supervise children when it is being used so that they do not touch hot surfaces and are not near the appliancewhile it is in use. The product installation, must be performed by competent and qualified installers who are aware of the installation regulations in force. Before maintenance or cleaning disconnect the appliance from the mains and wait for it to cool down. Switch off the heating element before removing the pots. The power cable must not be replaced by user. Please contact qualified personnel to replace apparatus cable. Care must be taken to put pots with flat bottoms on the heating top, to prevent spilling the fluid on the tops. · · · · · 13 General warnings · · GB IE Should the pyroceram top be even lightly cracked, immediately cut off the mains. Never put aluminium sheets, plastic containers, or other perishable material, on heated tops. Never use the pyroceram top as a support base for other objects. When using a crystal cover, only close it when the heating surfaces are well cooled. Use the cover as a protection of the top, and never for other purposes. We advise using lukewarm water and detergents to clean enameled elements. Rinse with water the stainless steel elements and dry using a soft cloth. Use sponges or a moist cloth to clean the tops, and remember that water in excess can damage the electric elements. Clean the hard stains using non abrasive detergents, or special products that can be found on the market, or warm vinegar. Clean the electric tops using a moist cloth, then lightly oil the the top when it is still warm. Clean the crystal surfaces after they have cooled down using a plastic scraper, and complete the cleaning using non-abrasive products that can be found on the market. Apply to skilled personnel when the equipment shows anomalies during its use. 16 Instructions for installation GB IE Below we give the instructions for qualified installers so that the installation, setting and maintenance operations are performed correctly and according to the regulations in force. Electrical connection Appliances with three-pole cable are set up for operation with alternating current at the voltage and frequency indicated both on the rating plate (on the lower part of the appliance) and the Table ((fig. The connection to the electricity supply must be made by a qualified person and following the regulations in force. When the appliance is to be installed above a built-in oven, the two appliances must be connected separately, to make it easier to take the appliances out and for electrical safety. Connection of the supply cable to the mains Connect a plug sized for the load indicated on the rating plate to the cable and connect it to a suitable socket. Avoid the use of reductions, two-way switches or adapters to avoid overheating or burning. For direct connection to the mains there must be an omnipolar switch with minimum opening between the contacts of 3 mm sized for the load and corresponding to the standards in force between the appliance and the mains. [. . . ] THIS EQUIPMENT MEETS TO EEC 73/23 AND EEC 93/68 FOR LOW VOLTAGE EQUIPMENT. Instructions for building in the units For installation in furniture, follow instructions given in fig. 1 It can be built into all units whose walls withstand a temperature 65°C higher than room temperature (EN 60335 - 2 - 6). Avoid installing the appliance near inflammable materials (e. g. curtains, cloths, etc. ). Dimensions, insertion and assembly The appliances are designed to be inserted in units with a minimum depth of 550 mm. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE REX RLB5M

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual REX RLB5M will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag