User manual REX RLB64X

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual REX RLB64X. We hope that this REX RLB64X user guide will be useful to you.

Lastmanuals help download the user guide REX RLB64X.


Mode d'emploi REX RLB64X
Download
Manual abstract: user guide REX RLB64X

Detailed instructions for use are in the User's Guide.

[. . . ] Ensure that the gas and electrical supply complies with the type stated on the rating plate, located near the gas supply pipe. Do not attempt to modify the appliance in any way. q Ensure the control knobs are in the `OFF' position when not in use. When using other electrical appliances, ensure the cable does not come into contact with the hot surfaces of the cooking appliance. Unstable or misshapen pans should not be used on the hob as unstable pans can cause an accident by tipping or spillage. [. . . ] * Costs incurred for calls to put right an appliance which is improperly installed or calls to appliance outside the United Kingdom. Before you move, please contact your nearest Customer Care centre, listed below, to give them details of your new home. They will then ensure that the local Service Organisation is aware of your move and able to look after you and your appliances. France Senlis +33 (0)3 44 62 22 22 Germany Nürnberg +49 (0)911 323 2600 Italy Pordenone +39 (0)1678 47053 Sweden Stockholm +46 (0)20 78 77 50 UK Newbury +44 (0)1635 522 799 11 Instructions for the Installer Engineer technical data OVERALL Width: Depth: Height: Weight: DIMENSIONS 580 mm. SUPPLY CONNECTIONS Gas: RC 1/2 inch (1/2 inch male) Rear right hand corner Electric: 230-240V 50Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse. This appliance complies with the EEC Directive No 89/336, concerning suppression of radio electrical interference. CUT OUT DIMENSIONS Width: 550 mm. Thickness: 40 mm. Ignition HT Spark Spark Generator Spark Gap Ispra Control's BF 50046 - 240V 0. 6 YA T 120 Fixed Rear Left Burner (semi rapid) Heat Input 1. 9 kW (6483 BTU/HR) Front Left Burner (rapid) Heat Input 2. 9 kW Natural Gas (9895 BTU/HR) 2. 7 kW L. P. G. (9212 BTU/HR) CHARACTERISTICS TYPE OF GAS BURNER RAPID (large) MAX MIN Rear Right Burner (semi rapid) Heat Input 1. 9 kW (6483 BTU/HR) Front Right Burner (auxiliary) Heat Input 1. 0 kW (3412 BTU/HR) SEMI-RAPID (medium) MAX MIN AUXILIARY (small) MAX MIN POSITION NOMINAL THERMAL POWER kW NOMINAL FLOW RATE m3/h NOZZLE REFERENCE 1/100 mm NOMINAL THERMAL POWER kW NOMINAL FLOW RATE VALUE = 37. 78 MJ/m3 Ws - 50. 7 MJ/ m3 NATURAL GAS 20 mbar 2. 9 0. 65 1. 9 0. 45 1. 0 0. 33 0. 276 119 0. 062 Adjust. 0. 181 96 0. 043 Adjust. 0. 095 70 0. 031 Adjust. VALUE = 49. 92 MJ/Kg LPG GAS 28-30/37 mbar 2. 7 0. 65 1. 9 0. 45 1. 0 0. 33 g/h 195 86 46. 8 40 137 71 32. 4 32 72 50 23. 8 28 NOZZLE REFERENCE 1/100 mm Burner Dia. Tap By-pass 1/100 mm 28 32 40 Tap colour CLASS APPLIANCE: 3 APPLIANCE CATEGORY: II2H3+ APPLIANCE GAS SUPPLY: Natural gas G20 / 20mbar Auxiliary Semi-rapid Rapid Red/Red Blue/Blue Black/Black Aeration adjustment none 12 Important safety requirements This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition). Detailed recommendations are contained in the following British Standards Codes Of Practice: B. S. The hob should not be installed in a bed sitting room with a volume of less than 20 m3. If it is installed in a room of volume less than 5 m3 an air vent of effective area of 110 cm2 is required. The space behind the kitchen unit ("b") can be used for connections. 4 FO 2108 5 Fitting the hob to the worktop Before fitting the hob into the cut out, an adhesive seal must be fitted to the underside outside edge (Fig. It is essential that no gaps are left in this seal in order to prevent spillage near the hob seeping into the cabinet below. A 1) Remove the pan supports, the burners caps and crowns and turn the hob upside down, taking care the ignition candles are not damaged in this operation. 2) Place the sealing gasket all around the glass top edge as shown in diagram 4. 3) Fit the hob in the cut out and push it down until the glass top and the working top make contact, as shown in diagram 5. FO 2107 a) Sealing gasket 20 min 15 Electrical connections Any electrical work required to install this appliance should be carried out by a qualified electrician or competent person, in accordance with the current regulations. Permanent Connection In the case of a permanent connection, it is necessary that you install a double pole switch between the appliance and the electricity supply (mains), with a minimum gap of 3 mm. between the switch contacts and of a type suitable for the required load in compliance with the current electric regulations. The switch must not break the yellow and green earth cable at any point. The manufacturer declines any liability should these safety measures not be observed. This appliance is designed to be connected to a 230-240V 50Hz AC electrical supply. Before switching on, make sure the electricity supply voltage is the same as that indicated on the appliance rating plate. The rating plate is located on the bottom of the hob. [. . . ] Turn on the burner gas supply and ignite another burner supply. The pressure reading should be nominally 20mbar and must be between 17 mbar and 25mbar. Turn off the burner supplies. 20 Servicing A: Removal Of Hob Top 1. Remove the panstands and each burner cap and crown. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE REX RLB64X

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual REX RLB64X will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag