Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ROBLIN ARROW MURALE 900. We hope that this ROBLIN ARROW MURALE 900 user guide will be useful to you.
Lastmanuals help download the user guide ROBLIN ARROW MURALE 900.
Manual abstract: user guide ROBLIN ARROW MURALE 900
Detailed instructions for use are in the User's Guide.
[. . . ] Thank you for buying a Roblin product which has been manufactured to the highest quality standards to meet your requirements. We recommend you carefully read this booklet in which you will find instructions for installation, hints for use and maintenance. The Instructions for Use apply to several versions of this appliance. Accordingly, you may find descriptions of individual features that do not apply to your specific appliance. [. . . ] Each chimney stack consists of two sections. 1 - item 7a & b) first by expand-ing the chimneys slightly to allow them to clamp around the bracket item 2 and secure the chimney stacks to the brackets using the two M4 screws item 12c provided. Fit the lower chimney sections by expanding the chimneys slightly to allow them from the top of the canopy to clamp around the upper chimney sections. Fit the recirculation spigot R onto the upper chimney wall bracket using the same fixing screws (Fig. Connect the ducting 150mm (6 INS) not provided between motors item 6 and the recirculation spigot and secure the connections with appropriate clamping rings or adhesive tape. Before fitting the chimney to the canopy make the electrical connection as described in the section titled ELECTRICAL. When the electrical connection has been made, test the lights and the fan motor. Insert the charcoal filter into the base of the motor housing and secure the filter with two metal securing straps item A as illustrated in Fig. Each chimney stack consists of two sections. 1 - item 7a & b) first by expand-ing the chimneys slightly to allow them to clamp around the bracket item 2 and secure the chimney stacks to the brackets using the two M4 screws item 12c provided. Fit the lower chimney sections by expanding the chimneys slightly to allow them from the top of the canopy to clamp around the upper chimney sections. To use the cooker hood in the recycling mode re-programme the hood as follows: Starting in the recycling mode (the contaminated air passes into the hood through the grease filters and the purifying activated charcoal filter and back out into the kitchen through grilles). Press the `+' button (while the motor and lights are switched `OFF') until the five LED lights will flash twice to indicate confirmation that the cooker hood is in the recycling mode. reverting to the extraction mode (The cooker hood is ducted to the outside). Press the `+' button (while the motor and lights are switched `OFF') until the five LED lights will flash once to indicate confirmation that the cooker hood is in the extraction mode. B - BASIC INSTRUCTIONS Lighting Press LED button 1 to switch `ON' the lights and the LED will illuminate to confirm the lights are switched `ON'. Motor Press LED button 2 to switch `ON' the fan motor (and adjust the speed of the fan motor by pressing the LED button `+' and `-`) and the LED lights 2, 3 and 4 will illuminate. The fan speed will be increased if constant pressure is kept on the (+) button. LED 2 : Minimum speed - cooking with one pan or simmering LED 2 & 3 : Medium speed - normal cooking with up to 4 pans LED 2, 3 & 4 : Maximum speed - frying and cooking foods with strong odours Press LED button 5 to obtain the boost position for maximum effect and the LED will illuminate to confirm fan is switched `ON'. c - COMPLEMENTARY INSTRUCTIONS · Boost speed : To obtain the best performance it is advisable to switch `ON' the cooker hood a few minutes (in the boost setting) before you start cooking. to program the complementary function , proceed as follows: - Press LED button 2 to switch `ON' the fan motor and adjust the speed of the fan by pressing the LED button `+' and `-`. You should keep applying pressure to the `+' and `-` button until the required speed is selected. [. . . ] In the event of any malfunction or anomaly, notify your fitter who will have to check the appliance and its connection. ⷠIn the event of damage to the mains supply cable, this can only be replaced by at approved repair centre appointed by the manufacturer who will have the required tools and equipment to carry out any repairs properly. Repairs carried out by other persons will invalidate the guarantee. ⷠUse only genuine spare parts. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ROBLIN ARROW MURALE 900
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ROBLIN ARROW MURALE 900 will begin.