User manual ROBLIN ATRIUM 600 DIMENSIONS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ROBLIN ATRIUM 600. We hope that this ROBLIN ATRIUM 600 user guide will be useful to you.

Lastmanuals help download the user guide ROBLIN ATRIUM 600.


Mode d'emploi ROBLIN ATRIUM 600
Download
Manual abstract: user guide ROBLIN ATRIUM 600DIMENSIONS

Detailed instructions for use are in the User's Guide.

[. . . ] The ducting used must be made from fire retardant materials and the correct diameter must be used, as incorrect sized ducting will affect the performance of this cooker hood. When the cooker hood is used in conjunction with other appliances supplied with energy other than electricity, the negative pressure in the room must not exceed 0. 04 mbar to prevent the fumes from combustion being drawn back into the room. The appliance is for domestic use only and should not be operated by children or people who are infirm without supervision. [. . . ] Wherever possible utilise rigid circular pipe which has a smooth interior, rather than the expanding concertina type ducting. The above assumes our 150 mm (6 INS) ducting is being installed. Please note ducting components and ducting kits are optional accessories and have to be ordered, they are not automatically supplied with the chimney hood. Fit the non-return backflow flaps C over the round outlet item 6 on top of the canopy while pressing Down until they snap into position, and then connect the ducting 150mm (6 INS) and secure the connections with appropriate clamping rings or adhesive tape (Fig. Before fitting the chimney to the canopy make the electrical connection as described in the section titled ELECTRICAL. Each chimney stack consists of two sections. 2a - item 7) first by expanding the chimneys slightly around the bracket and secure the chimney stacks to the brackets using the M4 screws provided. Pull on the lower chimney item 5 and secure it temporarily unscrewing a little bit the lower self tapping screws as illustrated in Fig 9. Fit the recirculation spigot R onto the chimney bracket using the same fixing screws. Connect the ducting 150mm (6 INS) not provided between motors item 6 and the recirculation spigot and secure the connections with appropriate clamping rings or adhesive tape (Fig. Before fitting the chimney to the canopy make the electrical connection as described in the section titled ELECTRICAL. Two flashes of the LED lights 2, 3, and 4 = function is switched `ON'. While the 5 minutes timer is running, It is available to stop immediately the boost speed by pressing the led button 5. While the 5 minutes timer is running, the indication of saturation of the filters is switched `OFF'. If a pre-set stop for the hood is switched `ON' and the 5 minutes timer is still running, the boost speed will be switched `OFF' together with the pre-set stop for the hood after the count down of 5, 10 or 15 minutes. It is available to stop the boost speed before the count down of the preset stop of the hood by pressing the led button 5. Pre-set stop for the hood : This function allows you to program the cooker hood to automatically stop cooking after a pre-set period. The lights and the fan motor should be switched `OFF' to set the timer. Indication of saturation of the metal grease filters : After 200 hours use, one quick flash of the LED 1 will indicate that you must clean the metal grease filters. To reset the 200 hours timer back to zero requires the motor and lights must be switched `OFF'; then and proceed as follows: Press the LED button `+' for 3 to 4 seconds and the LED lights 1, 2, 3, 4 and 5 will flash to confirm the programme has been reset to zero. Indication of saturation of the active charcoal filter : After 400 hours use, two quick flash of the LED 1 will indicate that you must replace the active charcoal filter and clean the metal grease filters. Two flashes of the LED lights 1, 2, 3, 4 and 5 = function is switched `ON'. [. . . ] The filter should be replaced at least every three months or more frequently if the hood is used for more than three hours per day. Your product is designed and manufactured with high quality materials and components, which can be recycled and reused. please inform yourself about the local separate collection system for electrical and electronic product. Please act according to your local rules and do not dispose of your old products with your normal household waste. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ROBLIN ATRIUM 600

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ROBLIN ATRIUM 600 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag