User manual ROCKTRON IFXONLIN

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ROCKTRON IFXONLIN. We hope that this ROCKTRON IFXONLIN user guide will be useful to you.

Lastmanuals help download the user guide ROCKTRON IFXONLIN.


Mode d'emploi ROCKTRON IFXONLIN
Download
Manual abstract: user guide ROCKTRON IFXONLIN

Detailed instructions for use are in the User's Guide.

[. . . ] USER'S MANUAL May be covered by one or more of the following: U. S. Patents #4538297, 4647876, 4696044, 4745309, 4881047, 4893099, 5124657, 5263091, 5268527, 5319713, 5333201, 5402498, 5493617 and 5638452. Foreign patents pending. Your Intellifex® Online has been tested and complies with the following Standards and Directives as set forth by the European Union: Council Directive(s): Standard(s): 89/336/EEC Electromagnetic Compatibility EN55013, EN50082-1 This means that this product has been designed to meet stringent guidelines on how much RF energy it can emit, and that it should be immune from other sources of interference when properly used. Improper use of this equipment could result in increased RF emissions, which may or may not interfere with other electronic products. [. . . ] When using a moderate amount of regeneration, switching out the delay with the input muted will generate a non-delayed signal which will play over the decaying regenerated signal which continues on after the delay is switched out. Muting the output (Post) of the delay results in the delayed signal being immediately turned off when the delay is switched out. This means that delays and regeneration will not continue once the delay is switched out. If the output were not muted, signals input before switching the delay out would be allowed to regenerate - even after switching out the delay. It is also possible to mute both the input and output (Both) so that no signal enters or exits the Delay section when it is not switched in. Level 1/2 These are individual level controls for each of the two delays available in the Delay section. These are not the same as the Delay Level parameter found in the Mixer function (which adjusts the overall level of both delay signals). Mute Type 14 Pan 1/2 This allows for the panning of each delay to the left or right output, if desired. The Pan parameter is adjustable from 0 to 100--where 0 is full left, 100 is full right and 50 is center. These parameters determine the amount of time after a signal is input that the delayed signal will begin to reproduce the input signal. This parameter is provided for each delay and determines the number of times the delayed signal will repeat itself. This is achieved by feeding the delayed output back into the input. Higher levels of regeneration will result in more repeats. The Delay Type parameter determines whether the Stereo, Ping-Pong or 2Tap delay type is currently active. Dly Time 1/2 Regen 1/2 D Type Dl Hf Damp Delay High Frequency Damping determines the amount of high frequency content in the delayed and regenerated signals. Higher amounts of damping will result in less high frequency information in the delayed signal. 15 D. DUCKER SECTION The process of ducking enables the user to suppress the level of a given signal or effect dynamically, dependent upon the presence of another signal which is desired to be prominent. The ducking feature of the Intellifex Online works in conjunction with the Delay and Reverb sections to attenuate the delay and/or reverb level while a phrase is being played (resulting in a less cluttered, more intelligible sound), yet return each to its original level when the phrase ends--thus allowing for the full decay of the delayed and/or reverberated signal. DUCKER PARAMETERS Ducker In the HUSH; Delay; Ducker configuration, this parameter determines whether the Ducker is off or on. In the HUSH; Chorus; Delay; Reverb and HUSH; Pitch Shift; Delay; Reverb configurations, this parameter determines whether the Ducker is either (A) off, (B) operating on the delay, (C) operating on the reverb, or (D) operating on both the delay and reverb. Sensitivity This parameter determines the threshold point above which the ducker will begin attenuating the delay and/or reverb signal. Until the input signal reaches this level, the delay/reverb signal will not be affected. This parameter determines how much the delayed signal is attenuated (muted). It may be set for only a slight change in signal level or it can completely attenuate the delay/reverb signal so that no delayed or reverberated signal passes while ducking is active. This parameter is adjustable from . 2 seconds to 9 full seconds, and determines the length of time it takes for the muted delay signal to return to its original signal level after the input signal falls below the threshold point set by the Sensitivity parameter. Attenuation Release Rate 16 E. [. . . ] Data string 82, which is miscellaneous data, will contain 12 data bytes. Error Messages "RECEIVE ERROR" - This message will appear on a receiving Intellifex Online if Check Sum bytes do not match, or if a status byte (MSB = 1) is received when a data byte was expected. This message also appears if a knob is turned or a button is pressed during reception. This message also appears if System Exclusive strings are sent too fast, without a long enough pause between strings. "DUMP ERROR" - This message will appear if MIDI Data is received at the MIDI IN while dumping is in progress. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ROCKTRON IFXONLIN

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ROCKTRON IFXONLIN will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag