[. . . ] · The velocity values of Note Off messages are ignored.
n = MIDI channel number: 0H~FH (Ch. 1~16) mm, ll = the value of the parameter specified by RPN/NRPN mm = MSB, ll = LSB Volume (Controller number 7) Status BnH 2nd byte 07H 3rd byte vvH 0H~FH (Ch. 1~16) 00H~7FH (0~127), Initial value = 64H (100)
q Note on
Status 9nH 2nd byte kkH 3rd byte vvH 0H~FH (Ch. 1~16) 00H~7FH (0~127) 01H~7FH (1~127)
n = MIDI channel number: kk = note number: vv = note on velocity:
n = MIDI channel number: vv = Volume:
· Not received when Rx. NOTE MESSAGE = OFF. (Initial value is ON) · For Drum Parts, these messages are not received when Rx. NOTE ON = OFF for each Instrument.
· Volume messages are used to adjust the volume balance of each Part. · Not received when Rx. VOLUME = OFF. (Initial value is ON) Pan (Controller number 10) Status BnH 2nd byte 0AH 3rd byte vvH 0H~FH (Ch. 1~16) 00H~40H~7FH (Left~Center~Right), Initial value = 40H (Center)
q Polyphonic Key Pressure
Status AnH 2nd byte kkH 3rd byte vvH 0H~FH (Ch. 1~16) 00H~7FH (0~127) 00H~7FH (0~127)
n = MIDI channel number: vv = pan:
n = MIDI channel number: kk = note number: vv = key pressure:
· Not received when Rx. POLY PRESSURE (PAf) = OFF. [. . . ] 00H~7FH (0~127) EOX (End Of Exclusive)
The System Exclusive Messages Transmitted and received by the CF-10/EXR-3 are: messages related to Mode Setting, Universal Realtime System Exclusive messages, Data Requests (RQ1), and Data Set (DT1).
9
CF-10/EXR-3 MIDI Implementation
3. Individual Parameter Transmission (Model ID=42)
Individual Parameter Transmission transmits data (or requests data) for one parameter as one exclusive message (one packet of "F0 . . . . . In Individual Parameter Transmission, you must use the Address and Size listed in the following "Parameter Address Map". Addresses marked at "#" cannot be used as starting addresses.
s System Realtime Message
q Active sensing
Status FEH * This will be transmitted constantly at intervals of approximately 250 ms.
s System Exclusive messages
"Identity Reply" and "Data Set 1 (DT1)" are the only System Exclusive messages transmitted by the CF-10/EXR-3. When an appropriate "Identity Request Message" and "Data Request 1 (RQ1)" message are received, the requested internal data will be transmitted. Identity Reply Status F0H Byte Data byte 7EH, dev, 06H, 02H, 41H, 42H, 00H, 00H, 06H, ssH, ssH, ssH, ssH Status F7H
Explanation FOH Exclusive status 7EH ID number (Universal Non-realtime Message) dev Device ID (use the same as the device ID of Roland) 06H Sub ID#1 (General Information) 02H Sub ID#2 (Identity Reply) 41H ID number (Roland) 42H Device family code (LSB) 00H Device family code (MSB) 00H Device family number code (LSB) 06H Device family number code (MSB) ssH Software revision level ssH Software revision level ssH Software revision level ssH Software revision level F7H EOX (End of Exclusive) * Reply the message by the unique device ID (dev) when the device has received the "Identity Request Message" in the Broadcast. Data set 1 Status F0H Byte Data byte 41H, dev, 42H, 12H, aaH, bbH, ccH, ddH, . . . eeH, sum DT1 (12H) Status F7H
Explanation F0H Exclusive status 41H ID number (Roland) dev Device ID (dev: 00H~1FH, Initial value is 10H) 42H Model ID (GS) 12H Command ID (DT1) aaH Address MSB: upper byte of the starting address of the data to be sent bbH Address: middle byte of the starting address of the data to be sent ccH Address LSB: lower byte of the starting address of the data to be sent. Multiple bytes of data are transmitted in order starting from the address. : : eeH Data sum Checksum F7H EOX (End Of Exclusive) * The amount of data that can be transmitted at one time depends on the type of data, and data will be transmitted from the specified starting address and size. * Data larger than 128 bytes will be divided into packets of 128 bytes or less, and each packet will be sent at an interval of about 40 ms. 00~7F
F0 41 10 42 12 40 03 00 01 11 2B F7 F0 41 10 42 12 40 03 04 02 37 F7 F0 41 10 42 12 40 03 03 4C 6E F7 F0 41 10 42 12 40 03 15 40 68 F7
Distortion 2-Stk Value Hex. 00~7F
F0 41 10 42 12 40 03 00 01 11 2B F7 F0 41 10 42 12 40 03 04 03 36 F7 F0 41 10 42 12 40 03 03 4C 6E F7 F0 41 10 42 12 40 03 15 40 68 F7
Distortion 3-Stk (Default) Value Hex. 00~7F
F0 41 10 42 12 40 03 00 01 20 1C F7 F0 41 10 42 12 40 03 03 24 16 F7 F0 41 10 42 12 40 03 04 10 29 F7
Phaser ValueHex. 00-24-7F Value Hex. 00~7F
F0 41 10 42 12 40 03 00 01 21 1B F7 F0 41 10 42 12 40 03 05 44 74 F7 F0 41 10 42 12 40 03 07 28 0E F7
Auto Wah Value Hex. 00~7F
F0 41 10 42 12 40 03 00 01 22 1A F7 F0 41 10 42 12 40 03 0D 00 30 F7 F0 41 10 42 12 40 03 16 7F 28 F7
Rotary (Slow) Value Hex. 00~7F
F0 41 10 42 12 40 03 00 01 22 1A F7 F0 41 10 42 12 40 03 0D 7F 31 F7 F0 41 10 42 12 40 03 16 7F 28 F7
Rotary (Fast) Value Hex. 00~7F
F0 41 10 42 12 40 03 00 01 23 19 F7 F0 41 10 42 12 40 03 06 0B 2C F7 F0 41 10 42 12 40 03 08 68 4D F7
Stereo Flanger Value Hex. 0F~71
F0 41 10 42 12 40 03 00 01 24 18 F7 F0 41 10 42 12 40 03 06 27 10 F7 F0 41 10 42 12 40 03 08 36 7F F7
Step Flanger Value Hex. 00~7F
F0 41 10 42 12 40 03 00 01 30 0C F7 F0 41 10 42 12 40 03 15 40 68 F7 F0 41 10 42 12 40 03 16 68 3F F7
Compressor Value Hex. 00~7F
F0 41 10 42 12 40 03 00 01 31 0B F7 F0 41 10 42 12 40 03 15 40 68 F7 F0 41 10 42 12 40 03 16 7F 28 F7
Limiter Value Hex. 00~7F
F0 41 10 42 12 40 03 00 01 40 7C F7 F0 41 10 42 12 40 03 04 20 19 F7 F0 41 10 42 12 40 03 12 40 6B F7
Hexa Chorus Value Hex. [. . . ] F7 (1) (2) (3) (4) (5) address data checksum (6) (1) Exclusive Status, (4) Model ID (GS), (2) ID (Roland), (5) Command ID (DT1), (3) Device ID (17), (6) End of Exclusive
Example Settings Note name C C# D D# E F F# G G# A A# B Equal Temperament Just Temperament (Keytone C) 0 0 0 -8 0 +4 0 +16 0 -14 0 -2 0 -10 0 +2 0 +14 0 -16 0 +14 0 -12 Arabic Scale -6 +45 -2 -12 -51 -8 +43 -4 +47 0 -10 -49
Next we calculate the checksum. 40H + 01H + 33H + 0CH=64 + 1 + 51 + 12=128 (sum) 128 (sum) ÷ 128 = 0 (quotient) . . . 0 (remainder) checksum = 128 - 0 (remainder) = 128 = 80H In this case, however, the checksum value should be 00H, not 80H. You should use 00H if the remainder is 0. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ROLAND CF-10
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.