User manual ROLAND M-300

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ROLAND M-300. We hope that this ROLAND M-300 user guide will be useful to you.

Lastmanuals help download the user guide ROLAND M-300.


Mode d'emploi ROLAND M-300
Download
Manual abstract: user guide ROLAND M-300

Detailed instructions for use are in the User's Guide.

[. . . ] Owner's Manual Before using this unit, carefully read the sections entitled: "IMPORTANT SAFETY INSTRUCTIONS" (p. 2), "USING THE UNIT SAFELY" (p. 3­5), and "IMPORTANT NOTES" (p. These sections provide important information concerning the proper operation of the unit. [. . . ] Press [F6 (GLOBAL SCOPE)]. fig. ScrRecallSafe. eps Synchronizing scene memories with M-48 memories Synchronizing M-48 store operations If desired, M-48 memories can be stored simultaneously when a scene memory is stored on the M-300. The current memory of each M-48 unit will be stored to the specified memory number (except for M-48 units whose MEMORY SAFE function (p. 171) is on). Scenes stored by this operation are set so that when they are recalled, the memories of the M-48 units will also be recalled. 1. Access the SCENE screen. Scene memory The GLOBAL SCOPE popup will appear. 2. Select the scene number to use as the destination for the 3. Use the channel recall scope buttons of [F1 (CH 1­32)] to specify the channel recall scope. store operation, and press [F2 (STORE)]. fig. ScrSceneStore2. eps 4. Specify the scope of parameters that will be recalled for the channels you selected in step 3 using the channel recall scope buttons. 5. Use the channel recall scope buttons of [F2 (AUX/MTX/ MAIN)] to specify the channel recall scope. fig. ScrRecallSafeOut. eps The SCENE STORE popup will appear. 3. Verify the scene name shown in the name edit field, and edit it if desired. The M-48 memory will be stored with the same name. 4. In the M-48 MEMORY section, add a check mark to the STORE button 1 and specify the memory number 2 . fig. ScrM48MemStore_Guide. eps 6. Specify the scope of parameters that will be recalled for the channels you selected in step 5 using the channel recall scope buttons. 1 2 122 Scene memory The function buttons have the following operations: By holding down [SHIFT] and pressing [ ] or [ ], you can quickly move the cursor between the name edit field and M-48 MEMORY. [F1 ( PREV UNIT)] [F2 (NEXT UNIT )] [F7 (MEMORY SAFE)] Turns the MEMORY SAFE function on/off for the target M-48 unit. Change the target unit. You can press [F6 (MEMORY LIST)] to access the M-48 MEMORY LIST popup, where you can view the M-48's memory names. [F8 (CLOSE)] 5. Press [F8 (STORE)]. fig. ScrSceneStore_Conf. eps Synchronizing M-48 recall operations For each scene memory, you can specify whether M-48 memories will be recalled, and also specify the memory number that the M48 units will recall. A confirmation message will ask you to confirm the Store operation. When you recall the scene that contains this setting, each M-48 will recall its memory (except for M-48 units whose MEMORY SAFE function (p. Access the RECALL PARAMETER EDIT popup for the desired scene. If the user preference CONFIRMATION select button "SCENE/LIB STORE" is unchecked, the Store operation will be executed without showing the confirmation message. fig. ScrRecallParam. eps 6. Press [F8 (STORE)] to execute the Store operation. The operation will be cancelled if you press [F7 (CANCEL)]. If you want to exclude a specific M-48 unit from the memory store operation, use the M-48's MEMORY SAFE function (p. In the M-48 MEMORY area, add a check mark to the RECALL button 1 and specify the memory number 2 . fig. ScrM48MemRecall_Guide. eps M-48 MEMORY LIST popup To access the M-48 MEMORY LIST popup, press the SCENE STORE popup's [F6 (MEMORY LIST)] button. Here you can verify the memory name of the M-48's storage destination. fig. ScrM48MemList_Guide. eps 1 2 Scene memory 3. Press [F8 (OK)] to finalize the change and close the popup. 1 2 If you press [F7 (CANCEL)], your changes will be cancelled and the popup will close. If you want to exclude the memory of a specific M-48 unit from recall, use the M-48's MEMORY SAFE function (p. 171). 1 Unit indication This indicates the M-48 unit that is the object of the M-48 MEMORY LIST popup. 2 Memory list This indicates the memory number and name. The memory of the current memory number is shown in green. 123 USB memory recorder About the USB memory recorder The M-300 provides a two-track recorder function that uses USB memory. This function allows you to choose any two sources from AUX1­8, MTX1­4, MAIN L, MAIN R, MAIN C, MAIN MONO, MAIN L+C, and MAIN R+C, and record the audio signal to USB memory as a WAV file, or to play back a WAV file from USB memory. About USB memory The USB memory used by the USB memory recorder must be able to read or write data with sufficient speed when used with the M-300. [. . . ] 150 221 For EU Countries For China For the USA DECLARATION OF CONFORMITY Compliance Information Statement Model Name : Type of Equipment : Responsible Party : Address : Telephone : M-300 Digital Mixer Roland Systems Group U. S. 801 West Orchard Drive, Suite 3, Bellingham, WA 98225 (360) 594-4282 For EU Countries CAUTION Apparatus containing Lithium batteries Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Discard used batteries according to the manufacturer's instructions. ADVARSEL! Lithiumbatteri - Eksplosionsfare ved fejlagtig håndtering. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ROLAND M-300

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ROLAND M-300 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag