User manual ROLAND SI-24 V1.00 MIDI IMPLEMENTATION

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ROLAND SI-24. We hope that this ROLAND SI-24 user guide will be useful to you.

Lastmanuals help download the user guide ROLAND SI-24.


Mode d'emploi ROLAND SI-24
Download
Manual abstract: user guide ROLAND SI-24V1.00 MIDI IMPLEMENTATION

Detailed instructions for use are in the User's Guide.

[. . . ] In case MIDI control Mode is turned off, the control should be done through R-BUS. 1. TRANSMITTED DATA AND RECOGNIZED RECEIVE DATA Channel Voice message Note On/Off This unit sends or receives Note On when it is operated under H mode. [. . . ] (*10) Transmits this only in case the DIGITAL IN is correctly input. Receiving message Controls fader movement and On/Off of LED. Controller Value --------------------------------------------------------------------------------------------------------------------------------------------FADER 1 00H ( 0) 00H - 7FH (0:bottom-127:top) FADER 2 01H ( 1) 00H - 7FH (0:bottom-127:top) FADER 3 02H ( 2) 00H - 7FH (0:bottom-127:top) FADER 4 03H ( 3) 00H - 7FH (0:bottom-127:top) FADER 5 04H ( 4) 00H - 7FH (0:bottom-127:top) FADER 6 05H ( 5) 00H - 7FH (0:bottom-127:top) FADER 7 06H ( 6) 00H - 7FH (0:bottom-127:top) FADER 8 07H ( 7) 00H - 7FH (0:bottom-127:top) FADER 9 08H ( 8) 00H - 7FH (0:bottom-127:top) FADER 10 09H ( 9) 00H - 7FH (0:bottom-127:top) FADER 11 0AH (10) 00H - 7FH (0:bottom-127:top) FADER 12 0BH (11) 00H - 7FH (0:bottom-127:top) FADER MASTER 0CH (12) 00H - 7FH (0:bottom-127:top) STATUS 1 20H, 30H, 40H, 50H (32, 48, 64, 80) (*11) 00H - 03H (0:off, 1:green, 2:red, 3:orange) STATUS 2 21H, 31H, 41H, 51H (33, 49, 65, 81) (*11) 00H - 03H (0:off, 1:green, 2:red, 3:orange) STATUS 3 22H, 32H, 42H, 52H (34, 50, 66, 82) (*11) 00H - 03H (0:off, 1:green, 2:red, 3:orange) STATUS 4 23H, 33H, 43H, 53H (35, 51, 67, 83) (*11) 00H - 03H (0:off, 1:green, 2:red, 3:orange) STATUS 5 24H, 34H, 44H, 54H (36, 52, 68, 84) (*11) 00H - 03H (0:off, 1:green, 2:red, 3:orange) STATUS 6 25H, 35H, 45H, 55H (37, 53, 69, 85) (*11) 00H - 03H (0:off, 1:green, 2:red, 3:orange) STATUS 7 26H, 36H, 46H, 56H (38, 54, 70, 86) (*11) 00H - 03H (0:off, 1:green, 2:red, 3:orange) STATUS 8 27H, 37H, 47H, 57H (39, 55, 71, 87) (*11) 00H - 03H (0:off, 1:green, 2:red, 3:orange) STATUS 9 28H, 38H, 48H, 58H (40, 56, 72, 88) (*11) 00H - 03H (0:off, 1:green, 2:red, 3:orange) STATUS 10 29H, 39H, 49H, 59H (41, 57, 73, 89) (*11) 00H - 03H (0:off, 1:green, 2:red, 3:orange) STATUS 11 2AH, 3AH, 4AH, 5AH (42, 58, 74, 90) (*11) 00H - 03H (0:off, 1:green, 2:red, 3:orange) STATUS 12 2BH, 3BH, 4BH, 5BH (43, 59, 75, 91) (*11) 00H - 03H (0:off, 1:green, 2:red, 3:orange) CH SELECT 1 60H (96) 00H, 02H (0:off, 2:red) CH SELECT 2 61H (97) 00H, 02H (0:off, 2:red) CH SELECT 3 62H (98) 00H, 02H (0:off, 2:red) CH SELECT 4 63H (99) 00H, 02H (0:off, 2:red) CH SELECT 5 64H (100) 00H, 02H (0:off, 2:red) CH SELECT 6 65H (101) 00H, 02H (0:off, 2:red) CH SELECT 7 66H (102) 00H, 02H (0:off, 2:red) CH SELECT 8 67H (103) 00H, 02H (0:off, 2:red) CH SELECT 9 68H (104) 00H, 02H (0:off, 2:red) CH SELECT 10 69H (105) 00H, 02H (0:off, 2:red) CH SELECT 11 6AH (106) 00H, 02H (0:off, 2:red) CH SELECT 12 6BH (107) 00H, 02H (0:off, 2:red) SHIFT 3DH (61) 00H, 02H (0:off, 2:red) INPUT 2CH (63) 00H, 02H (0:off, 2:red) OUTPUT 3CH (64) 00H, 02H (0:off, 2:red) BUS 4CH (65) 00H, 02H (0:off, 2:red) Tr1-12 5CH (66) 00H, 02H (0:off, 2:red) Tr13-24 6CH (67) 00H, 02H (0:off, 2:red) SURROUND ON 2DH (69) 00H, 02H (0:off, 2:red) PLAY 4EH (78) 00H, 02H (0:off, 2:green) REC 5EH (94) 00H, 02H (0:off, 2:red) (*11) Receives message in order subject that [MUTE] is On, [SOLO] is On, [REC/PLAY] is On and [AUTOMIX] is On. 7 Roland SI-24 MIDI Implementation System Exclusive Message Universal System Exclusive message INQUIRY MESSAGE Identity Request Status F0H Byte F0H 7EH Dev 06H 01H F7H Data Byte 7EH, Dev, 06H, 01H Status F7H 2. Appendices Decimal and Hexadecimal table (Hexadecimal number is shown with H. ) In MIDI documentation, data values and addresses/sizes of system exclusive messages etc. are expressed as hexadecimal values for each 7 bits. the following table shows how these correspond to decimal numbers. +------------+------------++------------+------------++------------+------------++------------+------------+ | dec | hex || dec | hex || dec | hex || dec | hex | +------------+------------++------------+------------++------------+------------++------------+------------+ | 0 | 00H || 32 | 20H || 64 | 40H || 96 | 60H | | 1 | 01H || 33 | 21H || 65 | 41H || 97 | 61H | | 2 | 02H || 34 | 22H || 66 | 42H || 98 | 62H | | 3 | 03H || 35 | 23H || 67 | 43H || 99 | 63H | | 4 | 04H || 36 | 24H || 68 | 44H || 100 | 64H | | 5 | 05H || 37 | 25H || 69 | 45H || 101 | 65H | | 6 | 06H || 38 | 26H || 70 | 46H || 102 | 66H | | 7 | 07H || 39 | 27H || 71 | 47H || 103 | 67H | | 8 | 08H || 40 | 28H || 72 | 48H || 104 | 68H | | 9 | 09H || 41 | 29H || 73 | 49H || 105 | 69H | | 10 | 0AH || 42 | 2AH || 74 | 4AH || 106 | 6AH | | 11 | 0BH || 43 | 2BH || 75 | 4BH || 107 | 6BH | | 12 | 0CH || 44 | 2CH || 76 | 4CH || 108 | 6CH | | 13 | 0DH || 45 | 2DH || 77 | 4DH || 109 | 6DH | | 14 | 0EH || 46 | 2EH || 78 | 4EH || 110 | 6EH | | 15 | 0FH || 47 | 2FH || 79 | 4FH || 111 | 6FH | | 16 | 10H || 48 | 30H || 80 | 50H || 112 | 70H | | 17 | 11H || 49 | 31H || 81 | 51H || 113 | 71H | | 18 | 12H || 50 | 32H || 82 | 52H || 114 | 72H | | 19 | 13H || 51 | 33H || 83 | 53H || 115 | 73H | | 20 | 14H || 52 | 34H || 84 | 54H || 116 | 74H | | 21 | 15H || 53 | 35H || 85 | 55H || 117 | 75H | | 22 | 16H || 54 | 36H || 86 | 56H || 118 | 76H | | 23 | 17H || 55 | 37H || 87 | 57H || 119 | 77H | | 24 | 18H || 56 | 38H || 88 | 58H || 120 | 78H | | 25 | 19H || 57 | 39H || 89 | 59H || 121 | 79H | | 26 | 1AH || 58 | 3AH || 90 | 5AH || 122 | 7AH | | 27 | 1BH || 59 | 3BH || 91 | 5BH || 123 | 7BH | | 28 | 1CH || 60 | 3CH || 92 | 5CH || 124 | 7CH | | 29 | 1DH || 61 | 3DH || 93 | 5DH || 125 | 7DH | | 30 | 1EH || 62 | 3EH || 94 | 5EH || 126 | 7EH | | 31 | 1FH || 63 | 3FH || 95 | 5FH || 127 | 7FH | +------------+------------++------------+------------++------------+------------++------------+------------+ (*) Decimal values such as MIDI channel, bank select, and program change are listed as one(1) greater than the values given in the above table. (*) A 7-bit byte can express data in the range of 128 steps. For data where greater precision is required, we must use two or more bytes. For example, two hexadecimal numbers aa bbH expression two 7-bit bytes would indicate a value of aa x 128 + bb. (*) In the case of values which have a +/- sign, 40H=-64, 00H=0, 3FH=+63, so that the decimal expression would be 64 less than the value given in the above chart. In the case of two types, 40 00H = -8192, 00 00H = 0, 3F 7FH = +8191. (*) Data marked "nibbled" is expressed in hexadecimal in 4-bit units. [. . . ] If the SI-24 received the message and the device ID of the message is same as its device. ID(= 1) or 7FH, the SI-24 transmits the following Identify Reply message. Identity Reply (*12) Status F0H Data Byte 7EH, Dev, 06H, 02H, 41H, mmH, mmH, 00H, 00H, 00H, 00H, ssH, ssH Description Status of System Exclusive Message Universal System Exclusive Non Real-time Header Device ID (= 00H) General Information (sub-ID #1) Identify Request (sub-ID #2) Manufacturer ID (Roland) Device Family Code (57H 01H) (SI-24) Device Family No. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ROLAND SI-24

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ROLAND SI-24 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag