Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ROLLS RPQ160. We hope that this ROLLS RPQ160 user guide will be useful to you.
Lastmanuals help download the user guide ROLLS RPQ160.
You may also download the following manuals related to this product:
ROLLS RPQ160 DATASHEET (73 ko)
Manual abstract: user guide ROLLS RPQ160
Detailed instructions for use are in the User's Guide.
[. . . ] In the absence of such purchase receipt, the warranty period shall be one (1) year from the date of manufacture. This warranty shall be invalid if the product is damaged as a result of defacement, misuse, abuse, neglect, accident, destruction or alteration of the serial number, improper electrical voltages or currents, repair, alteration or maintenance by any person or party other than our own service facility or an authorized Service Center, or any use violative of instructions furnished by us. This one-year warranty is in lieu of all expressed warranties, obligations or
ACTIVE 30 20 LOW SHELF 50 100 200 2 HIGH SHELF 4 6 10 LEVEL 0 200 100 FREQ 400 WIDTH 600 900 LEVEL 0 300 166 FREQ 800 WIDTH 1. 1k 1. 8k
RPQ160
Parametric Equalizer
1. 5 400
16
HZ 500
1
KHZ 30
-12 dB +12 CLIP
70 HZ 1. 5k
3
OCT
. 3
-15 dB +15
150 HZ
3k
3
OCT
. 3
-15
liabilities. ANY IMPLIED WARRANTIES, OBLIGATIONS, OR LIABILITIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL BE LIMITED IN DURATION TO THE ONE YEAR DURATION OF THIS WRITTEN LIMITED WARRANTY. [. . . ] These symbols warn that there are no user serviceable parts inside the unit. Do not attempt to service the unit yourself. Refer all servicing to qualified personnel. Opening the chassis for any reason will void the manufacturer's warranty. If liquid is spilled on the unit, shut it off immediately and take it to a dealer for service. Disconnect the unit during storms to prevent damage. Unpack and inspect the RPQ160 box and package. If obvious physical damage is noticed, contact the carrier immediately to make a damage claim. We suggest saving the shipping carton and packing materials for safely transporting the unit in the future. Please complete the Warranty Registration Card and return it to the factory. TABLE OF CONTENTS Introduction Warnings Inspection Table of Contents Description Front Panel Rear Panel Connection Operation Applications Schematic
1
1 1 1 1 2 2 2 3-4 4 5
Specifications Warranty
6 Back Cover
6
SCHEMATIC FRONT PANEL
Sheet: 1 of 1
R ev: JA C K M
30 20 LOW SHELF 50 100 200 2 HIGH SHELF 4 6 10 LEVEL 0 200 100 FREQ 400 WIDTH 600 900 LEVEL 0 300 166 FREQ 800 WIDTH 1. 1k 1. 8k 0 800 400 FREQ 2. 1k WIDTH 3. 3k 7k LEVEL 0 2k 900 FREQ 4k WIDTH 6k 12k LEVEL 0
DESCRIPTION
A
1. 5 400
Document Number: RPQ160SCH
ROLLS CORPORATION 5968 South 350 West Salt Lake City, UT 84107
J5 XLR
16 ACTIVE
HZ 500
1
KHZ 30
-12 dB +12 CLIP
70 HZ 1. 5k
3
OCT
. 3
-15 dB +15
150 HZ
3k
3
OCT
. 3
-15 dB +15
300 HZ
10k
3
OCT
. 3
-15 dB +15
600 HZ
20k
3
OCT
. 3
PWR
-15 dB +15
RCA X2 J2B
D1 LDSG
Title: RPQ160 PARAMETRIC EQ
P H O N E 1 /4 J4
POW ER
100K
3
2
C33 1U C35 503
7812 U9
R24
+12V
4560
4560
-12V
10K
U4A
C28 503
C31 1000U. 16V 2
51
R26 51
7
1
1
U10 7912
I
I
R23
6
5
2
3
4560
1
C27 503
D5
-12V
N4001
U3A
D4
10K 5
2
3
R17 10K
E1
E2
M C I 4 0 6 -4 0 2 4
-12V
7
E3
D7
C29 503
D6
C30 503
*= . ACTO R Y SELEC T
Size:
Rb Date: 19-Jul-2000
C10 10U
+12V
3
C9 10U
O
O
3
R68 -12V 1 0 K
R27 51
C34 10U
4
6
4560
1
1
SW 1B DPDT
4 . 7 K
+12V
U3B
6
LDRR SW 1A
DPDT
D2
5
C8 . 0 0 1
2
T1
1
. 0 0 2 7
P100KC P3B
PL1
SW
HISHEL.
6
PLUG
C7
AC M ALE
3 . 3 K
1
3
4
SPST
1
4560
7
R65 33K
R66
P100KC
+12V
3 . 3 K
U8B
7
C U T /B O O S T
120P.
-12V
+12V
P100K
120P.
C6
6
5
BAND 4
R14 10K
4560
2
3
C20
P100K X2 300 -10K
P10B
P100K
P100K P9
P100K P12
LDRR
C19 220P.
. REQ
R58 *
120P.
7
P6
LO AD
120P.
R62
R63 3 . 3 K
4560
R12 10K
R48 *
2
+12V
R52 22K
OVER
U2B
D3 Q1
C21
10K
1
P100K X2
4560 R60
-12V
P10A
U7A
2
R10 4 . 7 K
R19
10K
4560
2
3
P14
3
C26 10U
P100KW P2
W ID T H P100K
P11
R67
P100K X2
R11 10K
C5
. 1
-12V
U8A
P13A
R50
10K
6
5
C25 . 0 4 7
R53 3 . 3 K
2
1
P13B P100K X2 650 -20K
BAND 3
2K
. REQ
5
C22 10U
CR2 1N4148
W ID T H
100K
P100K
R18
R9 4 . 7 K
7
10K
R8
*
R57
*
7
4560
4
P100KC P1B
7
R36 47K
+12V
SHEL.
4560
R35 33K
U1B
4560
R45 33K
R46 47K
+12V
+12V
U6B
U5B
C16
120P.
6
6
LO W
5
120P.
6
5
6
5
P100K X2
BAND 2
R41 22K
R7
HP.
3 . 3 K
2
C12
R6 33K
BAND 1
R31 22K
R5 1K
R44
C4 . 1
P1A
1N4148
R34 4 . 7 K
4 . 7 K
7 0 - 1 . 5 K
. REQ
C15 470P.
1
4560
C11 . 0 0 1
120P.
R28 *
R33 4 . 7 K
R42 22K
R32 22K
R43 4 . 7 K
R38 *
2
. REQ
P100K X2
P100KC
P4B
-12V
R4 10K 1%
R3 10K 1%
U1A
C13 . 4 7
C2
R40
P4A P100K X2
-12V
U5A
10K 1%
10K 1%
120P.
4560
R1
C1
2
4560
R2
2
3
3
C18 10U
P8
W ID T H
W ID T H P100K
P100K
C14 10U
P5
R37
3
P H O N E 1 /4 J1
J3
. PC
RCAX2 J2A
1
5
XLR
*
*
R47
P100K X2
2
3
10K
-12V
R30 10K
U6A
P7A
C17 . 2 7
2
1
1
150 -3K
CR1
C3
. 2 7
5
P7B
5
3
6
3
4
1
4
4
1
8
6
3
6
3
4
4
1
3 . 3 K
5
6
4
R54 3 . 3 K
4
4
1
8
+12V
4560
120P.
3
R55 33K
R56 47K
1
6
5
47K
8
G
1
2
G
8
4
1
5
2
3
3
4
3 8
4
8
8
4
5
1 1 8
2 2
LOW SHELF: High Pass Filter control; adjusts the amount of low frequency rolloff from 500 Hz down to 16Hz for the entire output of the RPQ160. HIGH SHELF: Low Pass Filter control; adjusts the amount of high frequency rolloff from 1 kHz up to 20 kHz for the entire output of the RPQ160. NOTE: THERE IS NO BYPASS SWITCH FOR THE LOW OR HIGH SHELF FILTERS - SIMPLY TURN THE LOW SHELF COMPLETELY COUNTERCLOCKWISE, AND THE HIGH SHELF COMPLETELY CLOCKWISE TO BYPASS THESE CIRCUITS. LEVEL: Adjusts the overall signal level of the RPQ160.
NOTE: The following three descriptions are identical for all four bands of equalization. FREQUENCY: Selects the frequency to be boost or cut. The band frequency ranges are listed below: Band 1: 70 Hz to 1. 5 kHz Band 2: 150 Hz to 3 kHz Band 3: 300 Hz to 10 kHz Band 4: 600 Hz to 20 kHz WIDTH: (Q): Varies the shape or width of the equalization being boost or cut from . 3 to 3 octaves wide. LEVEL: Boosts or cuts the signal of the indicated band from -15 to +15 dB. Power Switch: Applies power to the RPQ160 when the unit is connected to a properly grounded ac outlet. [. . . ] The Low Shelf Sweep Diagram shows the response curve of the Low Self filter at its minimum and maximum setting.
Set at 16Hz O dB
OPERATION Cont. Shown below is the typical symmetrical response curve of a swept parametric band filter with the Frequency control set at 1 kHz, the Level set at +15 and -15 dB, and the Octave control set at . 3, . 5, 1, and 3. These curves remain consistent over the frequency spectrum, they simply shift to whatever frequency setting is indicated by the Frequency control. The shape is most narrow when the OCT control is set at . 3, and is widest at the 3 setting.
20 15 10 5
Amplitude, 5 dB/division
Set at 500 Hz 20 40 80 160 320 640 12k 16k 20k Frequency (Hz) LOW SHELF SWEEP DIAGRAM
The High Shelf Sweep Diagram shows the response curve of the High Self filter at its minimum and maximum setting.
O dB Set at 30 kHz
-5 -10 -15 -20 50 100 200 600 1k Frequency (Hz) 2k 6k 10k 20k
Set at 1 kHz 20 40 80 160 320 640 12k 20k 40k Frequency (Hz) HIGH SHELF SWEEP DIAGRAM
Please note that when the Low Shelf is set fully counterclockwise (16 Hz), the filter is essentially bypassed. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ROLLS RPQ160
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ROLLS RPQ160 will begin.