Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ROSIERES F 132. We hope that this ROSIERES F 132 user guide will be useful to you.
Lastmanuals help download the user guide ROSIERES F 132.
Detailed instructions for use are in the User's Guide.
[. . . ] Bear in mind that the distance between the lower edge of the hood and the hob must be 350 mm. Fix the metal bracket (A) to the wall using the 2 holes just drilled (Fig. 6); the screws for fixing the bracket are provided. Use the 2 cut-out triangles on the bracket to position it exactly along the vertical axis of the hood. [. . . ] 9); then, by means of the screw anchors and screws (F) provided, fix the bracket to the ceiling in such a way that it is positioned along the axis with your hood (Fig. - Use a flexible pipe and lock it to the air vent of the hood with a metal hose clamp - Fig. - For exhaust hoods, turn the upper flue over so that the air exhaust grid is in the lower section (Fig. Insert the extension flues setting them on the hood; extend the upper flue to the ceiling and secure with the 2 screws (H) - Fig. INSTALLATION IN FILTERING VERSION: Prepare the power supply within the telescopic flues (for the electrical connection, follow all the other instructions on the "Warnings" sheet). Fixing to the wall: for fixing to the wall refer to the instructions for the ducting version (see points 2, 3, 4), then continue with the instructions below. fixing the telescopic flues: - Assemble the tube support using a 4 screws kit (Fig. 9); - Then, by means of the screw anchors and screws (F) provided, fix the bracket to the ceiling in such a way that it is positioned along the axis with your hood (Fig. Take the air baffle and fit a flexible pipe to it (125 mm diameter) locking it with a metal hose clamp (pipe and clamps are not provided). Insert the extension flues setting them on the hood; extend the upper flue to the ceiling and secure with the 2 screws H (Fig. - Install the charcoal filter fitting the two filter clips in their housings (Fig. After cleaning the grease filters (and/or replacing the charcoal filters), restart the hour counter (RESET) by pressing the key P3 during display of the filter alarm. D) Drives the motor (calling the last speed used) and increases the speed until reaching maximum. L) Display: - signals the running speed - signals Automatic mode by displaying the letter "A". When the motor speed is changed, the running speed is displayed flashing 3 times, and then the letter "A" reappears. - signals the filter alarm (with motor off) by displaying the central segment for 30". FILTER ALARM: Displayed for 30" when the motor is off: After 30h of operation the central segment lights up on the display; It indicates that the grease filters need to be cleaned. After 120h of operation, the central segment flashes on the display; It indicates that the grease filters need to be cleaned and the charcoal filters replaced. After cleaning the grease filters (and/or replacing the charcoal filters), restart the hour counter (RESET) by pressing the key C during display of the filter alarm. GAS SENSOR SENSITIVITY: The sensitivity of the sensor can be modified to suit your requirements. The running speed and not the letter "A" must appear on the display); If not, press the key E. By means of the buttons C(-) and D(+) the desired sensitivity is set Store the "new" sensitivity by pressing the key E. [. . . ] - signals the filter alarm (with motor off) by displaying the central segment for 30". FILTER ALARM: Displayed for 30" when the motor is off: After 30h of operation, the letter "F" appears on the display; It indicates that the grease filters need to be cleaned. After 120h of operation, the letter "F" flashes on the display; It indicates that the grease filters need to be cleaned and the charcoal filters replaced. After cleaning the grease filters (and/or replacing the charcoal filters), restart the hour counter (RESET) by pressing the key C during display of the filter alarm. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ROSIERES F 132
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ROSIERES F 132 will begin.