User manual ROSIERES RTG 64

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ROSIERES RTG 64. We hope that this ROSIERES RTG 64 user guide will be useful to you.

Lastmanuals help download the user guide ROSIERES RTG 64.


Mode d'emploi ROSIERES RTG 64
Download
Manual abstract: user guide ROSIERES RTG 64

Detailed instructions for use are in the User's Guide.

[. . . ] 23 2 Description of the appliance a Pan support b Burner cap c Burner head d Ignition safety device e Ignitor f Burner base g Mains connection cable * Control knobs: h Front left i Back left j Back right k Front right * Depending on country of destination, the appliance may be supplied with or without a plug. The plug shown is for illustration only. 3 Warning and Safety instructions This appliance complies with all relevant legal safety requirements. Incorrect use can, however, lead to personal injury and damage to the appliance. To avoid the risk of accidents and damage to the appliance, read these instructions carefully before using it for the first time. [. . . ] Do not flambé under a cooker hood. The flames could set the cooker hood on fire. Ensure that the flames from the burner do not spread out beyond the base and up the sides of the pan. 8 Warning and Safety instructions Appliance faults In the event of damage or a defect, switch off the appliance immediately. Turn off the gas supply tap, and disconnect completely from the electricity supply. If the appliance has not yet been fully installed, the electricity cable must be disconnected from the supply point. If connected via a plug and socket, switch off at the socket and withdraw the plug. Do not reconnect the appliance to the mains electricity supply until after it has been repaired. If there is any damage to the ceramic surface the appliance must be disconnected from the mains electricity and gas supplies immediately and not used until it has been repaired. Repairs to the gas and electrical components of this appliance must only be carried out by a suitably qualified person. Repairs and other work by unqualified persons could be very dangerous and could damage the appliance. The manufacturer cannot be held liable for unauthorised work. Remember: Turn anti-clockwise to switch on, turn clockwise to switch off. The controls cannot be turned anti-clockwise from the small flame symbol to the "ß" position. 12 Using the gas hob Pans Burners small large Min. diameter at top of pan in cm small large 22 24 ­ Any heat-resistant pans can be used on a gas burner. ­ Remember when purchasing new pans that manufacturers usually refer to the diameter at the top of the pan in their documentation. ­ Refer to the chart above and ensure that the pan diameter falls within the minimum and maximum diameters given for the burner you are using. A pan which is too small will be unstable on the pan support. If the pan diameter is too large, flames can spread out to the sides and damage or burn the worktop, wall claddings or surrounding units and also parts of the hob. The manufacturer cannot be held liable for this type of damage. ­ Use a pan lid whenever possible to minimise heat loss. ­ Select pans which are suitable for the burner they are to be used on. In general: use larger diameter pans on the large burner and smaller diameter pans on the small burner. ­ Wide, shallow pans are preferable to tall, narrow ones. [. . . ] Ireland: IE II 2 H 3 + 20 mbar, 28-30/37 mbar. Depending on country, a set of jets for conversion to liquid gas is included with the hob. Conversion to another type of gas is described in the separate Installation Instructions supplied with this hob. Gas connection Connection to the appropriate gas supply, or conversion from one type of gas to another should be carried out in strict accordance with local and national safety regulations by an approved and registered gas installer (e. g. Corgi registered in the U. K. ) who is responsible for the correct functioning of the appliance when installed. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ROSIERES RTG 64

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ROSIERES RTG 64 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag