User manual RUSSOUND CA64
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual RUSSOUND CA64. We hope that this RUSSOUND CA64 user guide will be useful to you.
Lastmanuals help download the user guide RUSSOUND CA64.
Manual abstract: user guide RUSSOUND CA64
Detailed instructions for use are in the User's Guide.
[. . . ] 4-Source Multi-Zone Central Audio Controller/Amplifiers
CAi-Series
Instruction Manual
ROCK JAZZ
R&B CHILDRENS
VOLUME
· ON / OFF · VOLUME · SOURCE
SOURCE
STORE
REMOTE SENSOR
POWER
REMOTE SENSOR
CA-KP2 CA-LCD2
CA 6. 4i 6-Zone, 4-Source Central Controller/Amplifier
CA6. 4i 6 Zone -- 4 Source Central Controller/ Amplifier
1
2
3
4
5
6
POWER
ZONE
CA 4. 4i 4-Zone, 4-Source Central Controller/Amplifier
CA4. 4i 4 Zone -- 4 Source Central Controller/ Amplifier
1
2
3
4
POWER
ZONE
Patented
IMPORTANT SAFEGUARDS
12. Power - Cord Protection - Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at plugs, receptacles, and the point where they exit from the appliance. Cleaning - The appliance should be cleaned only as recommended by the manufacturer. Non-use Periods - The power cord of the appliance should be unplugged from the outlet when left unused for a long period of time. [. . . ] Zone 1 _________________ Zone 2 _________________ Zone 3 _________________ Zone 4 _________________
WIRING AT THE CONTROLLER
CAi System keypads are wired with CAT-5 wire. It is inexpensive and color coded for ease of installation. Due to the qualities of CAT-5 wire, when using it for keypad control wire with the CAi-Series, it is recommended to use the following color code for maximum performance. NOTE: 250ft run of wire maximum per keypad is recommended. CAT-5 Brown/White Brown Green Orange/White Orange Green/White Blue/White Blue Type Ground IR Signal 12VDC+ Source Select Source Select Channel Select Volume Balance
CLEAN INSTALLATIONS
For clean installations, we recommend using RJ-45 jumpers to run from the CAi controller to an RJ-45 Wall Plate then running your keypads from the Wall Plate. Figure 10 Connections with RJ-45 Wall Plate
GND
+12V
CH SEL
SEL3
Figure 9 Connections with CAT-5 wire
KEYPAD PORTS
1 2 3 4
12345678
RJ-45 using T568A Wiring Standard
ORANGE
ORANGE
BROWN
GREEN
BLUE
SEL1
VOL
IR
BAL
CAT-5 Cable
KEYPAD PORTS
1 2 3 4
8
INSTALLING KEYPADS
PUNCHDOWN TERMINALS
Figure 11 Punchdown Terminal on CAi keypad
INSTALLING THE KEYPADS
· The best infrared remote performance is achieved with the keypad away from any direct sunlight. Also consider convenience when choosing a location. · Choose a place that is easily seen from the position where a person is most likely to be located. · Check whether or not you can route the wire to the location you have chosen. · Purchase retro-fit plastic junction boxes (min. 18 cubic inches) or p-rings and cut in the boxes using a key-hole saw or sheetrock knife/hand saw. · If you are installing the optional DSC keypad you will need to use a double-gang electrical box. If you are installing both the optional DSC and DAN keypad you will need to install a triple-gang electrical box. · If you feel uncomfortable cutting into your walls and running wire through the walls, seek help from a professional installer or an electrician. · Route the wire to the junction box from the CAi location. · If using 22 AWG wire, connect each wire to the correct position 1 thru 8 using the included punchdown tool. · If using CAT-5 wire, connect each wire to its corresponding color labeled on the punchdown terminal. · Mount the keypad in the junction box and attach the Decora© plate. · The CA-KP2 keypad has source labels for your convenience. Insert the label in the keypad keeping the input number in sequence with the source selected. · Repeat the above steps until all keypads are installed.
The CAi Keypads come with 110 punchdown terminals. These terminals are quick, easy to install and provide a strong connection. [. . . ] 14
ELIMINATION OF BALANCE LINE
The following diagram shows how resistors may be used at the Keypad connection on the rear of the CAi master control unit, to provide 2. 5VDC to the balance control line for centering. This circuit will stabilize the balance line input and keep it centered. They can be used to free up one of the 8 required conductors if one is open, shorted or if an extra conductor is needed for a secondary IR receiver's signal in that zone. Position #7 is GND, #2 is 12VDC, #4 is Balance. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE RUSSOUND CA64 Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service. Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual RUSSOUND CA64 will begin.