Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual RYOBI W5502. We hope that this RYOBI W5502 user guide will be useful to you.
Lastmanuals help download the user guide RYOBI W5502.
Manual abstract: user guide RYOBI W5502SCHEMA ELECTRIC
Detailed instructions for use are in the User's Guide.
[. . . ] ß Do not use any phone in your building. ß Clear the room, building or area of all occupants. ß Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. [. . . ] ~ Gas dryers are not approved for mobile home installation. ~ If there is any doubt concerning installation, contact Miele's Technical Service Department.
U V 1-800-999-1360 techserv@mieleusa. com 1-800-565-6435 service@miele. ca
SAVE THESE INSTRUCTIONS
6
Installation
Front view
a Exhaust connection b Power cord with plug c Control panel d Door e Four height adjustable screw feet
Stand
A dryer stand, with drawer, can be purchased as an optional accessory.
7
Installation
Rear
a Handle for transportation (arrows) b Power cord with plug c Slot for module d Air intake e Gas connection f Exhaust connection with restriction insert
8
, WARNING : Do not remove the
restriction insert in the vent opening. It may result in poor drying results, damage to the laundry and higher Carbon monoxide emissions. Exception: The restriction insert must be removed if the exhaust connection if moved to the left or right side of the dryer.
Installation site , WARNING:
Do not install the dryer: - outdoors - in an environment with dripping water or weather - near flammable materials - in rooms which may contain gas or other fuels - in closets with solid doors - with other fuel-burning appliances in the same closet - in a location where its door could conflict with room doors. - next to a refrigerator - under a countertop - on top of a washer.
, The National Fuel Gas Code
restricts installations of gas appliances in garages. They must be 18 inches off the ground and protected by a barrier from vehicles.
9
Installation site
Confined space installation
^ When installed in any space with less than 122 square feet, minimum clearances around the dryer must be adhered to for proper ventilation and vents for make up air must be installed. ^ Do not install any other fuel-burning appliance in the same space as the dryer. Confined door openings Any doors limiting circulation must be louvered or otherwise ventilated. A minimum of 200 square inches (1, 290 cm2) of opening is required. It must be equally divided within 12" (30. 5 cm) from the top and bottom of the door. Minimum installation clearance
Sides: 0 " (0 cm) Top: 12" (30. 5 cm)
Rear: 0" (0 cm) (as close to wall as gas connection and venting allows) Front to door: 2" (5 cm) Make sure the dryer door can open completely once installed. The valve must be easily accessible to the consumer to turn on or shut off the gas supply after the appliance is installed. During any pressure testing of the gas system this appliance must be disconnected from the gas supply by closing its individual manual shut off valve. Any pipe connections must be made using a thread sealant approved for gas connections. Failure to correctly install these items could lead to a gas leak and subsequent explosion. The gas installation must be made in accordance with local codes or, in the absence of local codes, with National Fuel Gas Code, ANSI Z223. 1/NFPA 54 for USA
Gas type
The gas dryer is equipped for connection to a NATURAL GAS supply. The maximum heat output is 19, 500 BTU/H (5, 7 kW). Minimum gas supply pressure to obtain the required gas input is: 0. 15 psi (4" WC) for natural gas 0. 29 psi (8" WC) for LP gas. Maximum gas supply pressure before the gas pressure regulator 0. 37 psi (10" WC) for natural gas 0. 46 psi (13" WC) for LP gas.
or - Natural Gas and Propane Installation Code, CSA B149. 1 for Canada.
14
Gas connection
Gas supply
Installation material (hoses and adapters) must be provided by the installer. Gas connection distances
a Flare union adapter b 1/8" NPT pressure tapping plug c Gas shut-off valve For convenience (if allowed by code), an AGA or CGA approved flexible stainless steel gas hose (accordion type) may be used between the gas shut-off valve and the dryer. This will allow the appliance to be moved from the installation site for cleaning or servicing. Make sure that nothing rubs on the gas hose. [. . . ] Non-metallic flexible hose should not be used. In the United Stated foil-type flexible ducts should only be used if identified for use by the manufacturer as compliant with the Outline for Clothes Dryer Transition Duct, Subject ANSI/UL 2158A. In Canada, only flexible metal (foil-type) ducts specifically identified for use by the manufacturer should be used. For best drying results avoid extra long ducting with too many bends, angles or tight corners. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE RYOBI W5502
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.