User manual SABINE GRAPHI-Q2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SABINE GRAPHI-Q2. We hope that this SABINE GRAPHI-Q2 user guide will be useful to you.

Lastmanuals help download the user guide SABINE GRAPHI-Q2.


Mode d'emploi SABINE GRAPHI-Q2
Download
Manual abstract: user guide SABINE GRAPHI-Q2

Detailed instructions for use are in the User's Guide.

[. . . ] SUMMARY Summary of Features OF FEATURES GRQ3121 (1U, single channel, one input, two outputs) GRQ3122 (2U, dual channel, one input & output per channel) GRQ3121-S (1U, blank front panel slave, single channel, one input, two outputs) GRQ3122-S (1U, blank front panel slave, dual channel, one input & output per channel) GRQ2 Remote for WindowsTM Software included with every unit; runs up to 8 Graphi-Q2s per COM port (maximum of 2 COM ports) · All front panel controls are analog-style; signal path is digital · "Tweek-n-Peek" feature: Front panel adjustments of all parameters are shown in LED display screen · 24-bit A/D and D/A conversion, 32-bit processing · 20 to 20 KHz Frequency Response · +18 dBV Maximum Signal Input & Output · Floating Point SHARC Processor · >110 dB dynamic range Each channel provides (now with fully independent processing on 1x2 units): · 31-band graphic EQ, with ± 6 or 12 dB range (selectable) · Crossover: Bessel, Butterworth, and Linkwitz Reily filters; slopes to 48 dB/octave (Software only) · High Cut Filter (3KHz to 20KHz) and Low Cut Filter (20 Hz to 1KHz) · FBX Feedback Exterminator: up to 12 Filters, with Setup Mode (Auto Setup Mode via remote control) · Parametric Filters: up to 12 filters, numeric or graphic control (Software only) · Compressor/Limiter, with controls for ratio, threshold, and gain (attack, release, and knee adjustable with remote) · Digital Delay, with up to 1 second delay, adjustable in 20 microsecond increments · Bypass: dedicated switches for FBX, EQ, and Delay with built in LED indicators · LED Segmented Indicators: FBX Filters, Level, Gain Reduction · LED Point Indicators: FBX Setup, Remote, EQ Range · LED Character Display: Delay setting, EQ fader boost/cut, High Cut Filter setting Low Cut Filter setting, Compressor Ratio, Threshold, Gain, and Staus Messages. Back Panel: · XLR & 1/4" TRS inputs & outputs · RS-232 Serial input & output (additional serial input on the slave front panels) · Remote switching (8-position contact closure switch; allows switch selection of all 20 stored GraphiQ2 presets) Graphi-Q2 Remote Software Features: All front panel controls, plus more, including: · FBX filter depth & width adjustments; switchable to parametric filters (depth, width & frequency adjustments) · Graphic EQ filter width adjustments · Password protection · View & edit frequency response curves · 20 user-defined stored presets · · Control and link up to 8 Graphi-Q2s (16 channels of audio) per COM port (1 or 2 ports can be used) Future-proof FREE Flash RAM upgrade capability: upgrade your firmware and software from the Sabine website (www. Sabine. com)! Operating Guide Version 1: for Sabine Graphi-Q2s with: · GRQ2 Firmware Version 2. 20 · GRQ2 Remote Software Version 5. 0 1 B1-GRQ-2-OpGuide-v1-050125. pmd DECLARATION OF CONFORMITY EC - DECLARATION OF CONFORMITY CE MARKING We, the Manufacturer SABINE, INC. 13301 NW US HIGHWAY 441 ALACHUA, FLORIDA USA declare that the product EQUALIZER SABINE MODEL GRQ3100 Is in conformity with Council Directive: 73/23/EEC and 89/336/EEC (EMC Directives) Standards to which conformity is declared: EN 60065: 1993 EN 60742: 1995 EN 55103-1: 1997 EN 55022: 08:94 + a1:05:05 EN 55103-2: 1997 Manufacturer's Signature: Date: October 31, 2002 Name: Doran Oster, Sabine President 2 TABLE OF CONTENTS Summary of Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Section One: Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] In a multiple unit Graphi-Q network, you may NOT apply a True Stereo link from one unit to another, but only between the left and right channels of a single unit. All the units in a network may have their L-R channels linked, but each link will be independent of other units. A GRQ3122 or GRQ3122-S unit with channels linked in True Stereo may not also be part of an ABS or REL link for compressor values. Of course other parameters may be linked (ABS or REL) independently of compressor relationships. Crossover Settings Because crossover settings are unique to a specific set of speakers and their environment, these settings are not available in the link table. When a crossover is in effect, be careful about linking other filters - you may attempt to control a filter that is not appropriate for the frequency response of a given output. Relative Linking and Scale Values All changes made to cells that are REL LINKED will increment or decrement by an identical number of steps in the scale of the parameter. This may not always be a linear relationship. For example, changing the compressor ratio in one REL LINKED cell from 1:1 to 1. 4:1 will result in a change in another REL LINKED cell from 10:1 to 16:1. Both will move up one notch on the scale for compression ratio scale. Loading Memory Presets to Linked Units If you try to recall and load a stored memory (see Section 8. 6) to a unit with cells linked to any other unit, the screen shown at below will appear. 31 B2-GRQ-OpGuide-v9-031020. pmd SECTION EIGHT: USING GRQ2 REMOTE SOFTWARE If you elect to continue, the value your loaded memory puts into any linked cell on the chosen GraphiQ 2 will affect all other linked values as well. If you don't want this to happen, you must open the Link Table and remove the appropriate linking. Loading a preset that changes a linked parametric or sets an FBX filter back to an unset FBX filter will NOT load a corresponding filter change to linked channels. Linked channel FBX or parametric filters will remain unchanged unless your reset or manually program a change. 8. 3. 2. 9 Resetting Parameters When Units Are Linked (See also Section 8. 4) Resetting any parameter for any cell linked to another unit of channel will also change the value of all linked cells (except FBX filters and parametric filters in some instances). For ABS LINK, all linked cells will be reset to the default parameter values. For REL LINK, parameter values for linked cells will be decreased by the same amount as occurs by resetting the source cell. For example, resetting digital delay from 100 ms to the minimum value (1. 38 ms) in the source cell will reduce all REL LINKED cells' delay times by 98. 62 ms. For GRQ3122 and GRQ3122-S models, REL LINK parameters can be reset separately or simultaneously for each output. Whether channels are reset separately or together (checking either one or both channel boxes on the reset screen), the reset procedure for REL LINK will use the channel currently selected on the main screen as the source cell. IMPORTANT: When resetting REL, make sure the correct source is selected on the main software screen, if you are resetting just one output channel. Note that FBX filters can be reset only one unit at a time. [. . . ] 13301 HIGHWAY 441 ALACHUA, FL 32615-8544 including therewith a complete, detailed description of the problem, together with a legible copy of the original PROOF OF PURCHASE and a complete return address. Upon Sabine's receipt of these items: If the defect is remedial under the limited warranties and the other terms and conditions expressed have been complied with, Sabine will provide the necessary warranty service to repair or replace the product and will return it, FREIGHT COLLECT, to you, the purchaser. Sabine's liability to the purchaser for damages from any cause whatsoever and regardless of the form of action, including negligence, is limited to the actual damages up to the greater of $500. 00 or an amount equal to the purchase price of the product that caused the damage or that is the subject of or is directly related to the cause of action. Such purchase price will be that in effect for the specific product when the cause of action arose. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SABINE GRAPHI-Q2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SABINE GRAPHI-Q2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag