[. . . ] AQ09F AQ12F AQ18F AQ24F AQ09J AQ12J AQ18J AQ24J AQ09W AQ12W AQ18W AQ24W
Series Series Series Series Series Series Series Series Series Series Series Series
Split-type Room Air Conditioner
(Cooling and Heating)
E R DB98-26748A(1)
EHNIKA
ENGLISH
USER'S MANUAL
Register your product at www. samsung. com/global/register
Safety Precautions
The following safety precautions must be taken when using your air conditioner.
WARNING
Risk of electric shock. · Disconnect all remote electric power supplies before servicing, installing or cleaning. · This must be done by the manufacturer or its service agent or a similar qualified person in order to avoid a hazard. Users of this product are cautioned not to attempt repair of this product at their own discretion. [. . . ] Result: Each time you press the button: - The temperature is adjusted by 1°C - The indoor unit beeps If the room temperature reaches the set temperature (selected temperature+5°C), the air conditioner stops heating, but the fan is still operating. The air conditioner starts heating, provided that the room temperature is lower than the desired temperature (selected temperature+3°C). button one or more times )
4
Select the fan speed by pressing the until the required setting is displayed: Automatic (rotated : Low Medium High Maximum Result:
Each time you press the button, the indoor unit beeps. For the first three to five minutes, the fan operates very slowly until the air has been sufficiently warmed. Once the correct temperature has been reached, the fan is automatically set to the required speed.
5
E-10
To control the direction of the air flow, refer to pages 14.
Removing Excess Humidity
If the atmosphere in your room is very humid or damp, you can remove excess humidity without lowering the room temperature too much. 1 If necessary, press the Result: button.
The operation indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used. 1 If necessary, press the Result: button.
The operation indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used. The indoor unit beeps.
2
Press the Result:
button. The temperature and fan settings are adjusted automatically. The air conditioner cools or heats the room as quickly as possible. After 30 minutes, the air conditioner is reset automatically to the previous mode, temperature and fan settings. You can select the Turbo function in the Auto, Cool and Heat mode. If you select this function in the Dry or Fan mode, it will return to the Auto mode.
3
If you wish to stop the Turbo function before the end of the 30-minute period, button one or more times until disappears. press the Result: The air conditioner is reset automatically to the previous mode, temperature and fan settings.
4
To control the direction of the air flow, refer to pages 14.
E-13
Adjusting the Air Flow Direction Vertically
Depending on the position of the indoor unit on the wall of your room, you can adjust the position of the outer air flow blade on the bottom of the unit, thus increasing the efficiency of the air conditioner. 1 Press the Result: button one or more times as required. The outer blade is adjusted vertically.
2
If you want the blade to move up and down automatically when the air conditioner is operating, press the button. Result: The blade move up and down, around the base position set.
3
To stop the blade moving up and down, press the
button again.
Note
If you switch the air conditioner. . . Set to the initial position powered.
Adjusting the Air Flow Direction Horizontally
There are two sets of inner air flow blades. Just as the outer air flow blade can be adjusted vertically, the inner blades can be adjusted horizontally. 1 Adjust each set of inner blades to the required position, by pushing or pulling them sideways.
E-14
Setting the On Timer
The On Timer enables you to switch on the air conditioner automatically after a given period of time. [. . . ] If so: - Wait until the switch-on time is reached and the air conditioner starts up automatically - Cancel the timer (see pages 15 and 16 for further details) Check that there are no obstacles between you and the indoor unit. Check that you are close enough to the indoor unit (seven meters/yards or less).
The air conditioner does not operate with the remote control
No beep is heard when you press on the remote the control The air conditioner does not cool or heat
Check that you are pointing the remote control at the remote control sensor in the right of the indoor unit. Replace the remote control batteries if necessary.
Check that the correct operating mode has been selected (Auto, Cool, Heat). The room temperature may be too low or too high. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SAMSUNG AQ18JWAX
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.