User manual SAMSUNG AQV09NSB

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SAMSUNG AQV09NSB. We hope that this SAMSUNG AQV09NSB user guide will be useful to you.

Lastmanuals help download the user guide SAMSUNG AQV09NSB.


Mode d'emploi SAMSUNG AQV09NSB
Download
Manual abstract: user guide SAMSUNG AQV09NSB

Detailed instructions for use are in the User's Guide.

[. . . ] SPLIT-TYPE AIR CONDITIONER INDOOR UNIT Basic : AQV12NSA Model : AQV09NSB AQV12NSB Model Code : AQV09NSBN AQV12NSBN AQV09NSBX AQV12NSBX OUTDOOR UNIT AIR CONDITIONER THE FEATURE OF PRODUCT High Energy Efficiency BLDC Air Conditioner Simple Flat Grille Design good'sleep Mode : good'sleep Mode can help you sleep quickly and AQV09FCN, AQV12FCN, AQV09NSAN, AQV12NSAN soundly and wake up refreshed. Multi Functional Cleaning System : Silver Nano Health System and Deodorizing/ Catechin Filter are adopted. Silence Mode : When you use the "Silence Mode", you can experience extremely quiet operation of your air conditioner. AQV09FCX, AQV12FCX, AQV09NSAX, AQV12NSAX Refer to the service manual in the GSPN(see the rear cover) for the more information. Operating Instructions and Installation Contents 11. Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1-1 Installing the air conditioner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1-1 1-1 1-2 1-2 1-2 Power supply and circuit breaker 1-4 Disposing of the unit 1-5 Others 1-3 During operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] (Refer to the R/T TABLE) Yes No Is the resistance value of sensor connection pull_up 18. 2K?Yes No No No Reconnect the sensor connector. Change the position of sensor. Exchange the sensor. Exchange the PCB. Exchange the PCB. Normal operation Exit 400. 0 350. 0 300. 0 250. 0 200. 0 150. 0 100. 0 50. 0 0. 0 -50 -41 -32 -23 -14 4 103 -5 13 22 31 40 49 58 67 76 85 94 12-9 Samsung Electronics Troubleshooting 12-2-8 Discharge temperature sensor error 1. Checklist : 1) Is the sensor connector connected correctly?3) Does the both terminal of sensor satisfy the resistance value in accordance with temperature?4) Is the resistance value of sensor connection pull_up correct?Troubleshooting procedure Is the sensor connector connected correctly in accordance with a color?Yes No Is the temperature sensor connected correctly without separation?Yes Does the both terminal of sensor satisfy the resistance value in accordance with temperature?(Refer to the R/T TABLE) Yes No Is the resistance value of sensor connection pull_up 24K?Yes No No No Reconnect the sensor connector. Change the position of sensor. Exchange the sensor. Exchange the PCB. Exchange the PCB. Normal operation Exit 600. 0 500. 0 400. 0 300. 0 200. 0 100. 0 0. 0 0 8 104 112 120 128 136 144 152 160 16 24 32 40 48 56 64 72 80 88 96 Samsung Electronics 12-10 Troubleshooting 12-2-9 Coil temperature sensor error 1. Checklist : 1) Is the sensor connector connected correctly?3) Does the both terminal of sensor satisfy the resistance value in accordance with temperature?4) Is the resistance value of sensor connection pull_up correct?Troubleshooting procedure Is the sensor connector connected correctly in accordance with a color?Yes No Is the temperature sensor connected correctly without separation?Yes Does the both terminal of sensor satisfy the resistance value in accordance with temperature?(Refer to the R/T TABLE) Yes No Is the resistance value of sensor connection pull_up 18. 2K?Yes No No No Reconnect the sensor connector. Change the position of sensor. Exchange the sensor. Exchange the PCB. Exchange the PCB. Normal operation Exit 400. 0 350. 0 300. 0 250. 0 200. 0 150. 0 100. 0 50. 0 0. 0 -50 -41 -32 -23 -14 4 103 -5 13 22 31 40 49 58 67 76 85 94 12-11 Samsung Electronics Troubleshooting 12-2-10 Fan error 1. Checklist : 1) Isn't the fan locked?3) Does the both terminal of sensor satisfy the resistance value in accordance with temperature?4) Is the resistance value of sensor connection pull_up correct?Troubleshooting procedure Isn't the Fan locked? Remove the Fan lock. Yes Is the connector connected correctly? [. . . ] Close the front grille. Bio Filter Deodorizing Filter Samsung Electronics 14-8 14-6 Installation 14-6-1 Before Installation Keep the air conditioner outlet and inlet free from its surroundings. In case of installation, keep the symmetry and fix it to prevent vibration. The pipe length shall meet the standard as far as possible. 14-6-2 Installation Procedure Location Install the product in an area to guarantee the best cooling effect, convenience of piping and electric work, and inexistence of vibration or wind. Wall Drilling Drill the wall downward in a diameter of 60 to 65mm. Fixing Indoor Unit & Outdoor Unit Fix the air conditioner indoor unit securely to the wall. Secure the outdoor unit in a suitable position. Pipe Spooling & Connecting You shall cut the pipe with a pipe cutter and grind all the burrs of the cut surface. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SAMSUNG AQV09NSB

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SAMSUNG AQV09NSB will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag