User manual SAMSUNG AW12FADEB

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SAMSUNG AW12FADEB. We hope that this SAMSUNG AW12FADEB user guide will be useful to you.

Lastmanuals help download the user guide SAMSUNG AW12FADEB.


Mode d'emploi SAMSUNG AW12FADEB
Download
Manual abstract: user guide SAMSUNG AW12FADEB

Detailed instructions for use are in the User's Guide.

[. . . ] AW06FBNAA AW07FBNAA/AB/BA/DA/EA AW08FBNAA/AB AW09FBNAA/BA/CA/DA/EA/EB AW10FBDAA/BA/CA AW12FBDAA/BA//BC/CA/DA/EA/EB/EC AW14FBMAA/AB/BA/CA/DA/EA AW18FBMBA/BB/BC/BD/BE/DA/EA/EB AW18FBMCA/CB/CC AWT18FBMBA/BB/DA/EA/EB AWT19FBMBA/BB/EA/EB AWT20FBMBA/BB AW22FBMBA/BB/EA/EB AW24FBMBA/BB/BC/BD/EA/EB AW24FBMCA/CB/CC/CD AWT24FBMBA/BB/EA/EB/EC AW06A(G)BNAA AW07A(G)BNAA/AB/BA/DA/EA AW08A(G)BNAA/AB AW09A(G)BNAA/BA/CA/DA/EA/EB AW10A(G)BDAA/BA/CA AW12A(G)BDAA/BA/BC/CA/DA/EA/EB/EC AW14A(G)BMAA/AB/BA/CA/DA/EA AW18A(G)BMBA/BB/BC/BD/BE/DA/EA/EB AW18A(G)BMCA/CB/CC AWT18A(G)BMBA/BB/DA/EA/EB AWT19A(G)BMBA/BB/EA/EB AWT20A(G)BMBA/BB AW22A(G)BMBA/BB/EA/EB AW24A(G)BMBA/BB/BC/BD/EA/EB AW24A(G)BMCA/CB/CC/CD AWT24A(G)BMBA/BB/EA/EB/EC Window-type Room Air Conditioner ( Cool ) Acondicionador de aire doméstico sistema de tipo ventana ( Refrigeración ) Climatiseur de type Fenêtre ( Refroidissement ) O ar Condicionado de Window-Type ( Refrigeração ) Condizionatore d'aria per ambienti da finestra ( Raffreddamento ) E S F P I DB98-04666A(6) ITALIANO PORTUGUÊS FRANÇAIS ESPAÑOL OWNER'S INSTRUCTIONS MANUAL DE INSTRUCCIONES MANUEL D'UTILISATION MANUAL DE INSTRUÇÕES ISTRUZIONI PER L'USO ENGLISH Safety Precautions The following safety precautions must be taken when installing and using your air conditioner. 1 The air conditioner must be plugged into its own specific power source, which must be installed in compliance with national wiring, earthing and safety regulations. Depending on national regulations and your specific installation, you may need to install: A circuit breaker For further information on electrical requirements, contact a professional electrician. This device must be installed according to the national electrical rules. 2 Make sure that the unit is correctly ventilated at all times; do NOT place clothing or other materials over it. 3 NEVER spill liquids of any kind into the unit. Should this happen, unplug the unit and contact your installation specialist. 4 Do NOT insert anything between the air outlet blades, as it may damage the inner fan and you may be hurt. [. . . ] Press the button on the remote control. or Press the on the unit until the indicator lights up Press the button on the remote control. or Timer on the unit one or more times. Possible time is between 1 hour and 24 hour inclusive. Result: The remaining time is displayed and decreased by 1 hour automatically to indicate the remaining time. The air conditioner switches on automatically when the operating time reaches zero. You can change the setting mode, fan speed, and air flow direction after setting the On timer. To Cancel the On Timer To cancel the timer, press: Timer on the remote control or unit one or more times until " " is displayed. or on the remote control or unit (The air conditioner operates in the mode selected when the unit was last used. ) E-11 Setting the Off Timer Remote Control Control Panel The Off Timer enables you to switch off the air conditioner automatically after a given period of time. You can set the period of time from 1 hour to 24 hours. You can select the Off timer only when the air conditioner is on. 1 Check that the air conditioner has been switched on; if necessary, press the (On/Off) button. 2 Set the operating time by pressing: Timer on the remote control or Timer on the unit one or more times. Possible times are between 1 hour and 24 hour inclusive. Result: The remaining time is displayed and decreased by 1 hour automatically to indicate the remaining time. The air conditioner switches off automatically when the operating time reaches zero. You can change the setting mode, fan speed, and air flow direction after setting the Off timer. To Cancel the Off Timer To cancel the timer, press: Timer on the remote control or unit one or more times until " " is displayed. or on the remote control or unit (The air conditioner operates in the mode selected when the unit was last used. ) E-12 Setting the Sleep timer ENGLISH The Sleep Timer can be used when you are cooling your room to switch the air conditioner off automatically after a period of 8 hours. 1 2 If you wish to switch the unit off at a specific time, refer to page 12. Make sure that you have selected either COOL mode. Press the or Press the Result: button on the remote control button on the unit. Each time you press a button, the unit beeps. The "SLEEP" passes through the control panel for about 15 seconds and the " " will be displayed. The remaining time is displayed and decreased by 1 hour automatically to indicate the remaining time. The air conditioner will be controlled as illustration below. Remote Control Control Panel Cooling When the temperature has been increased by 1°C (after 1 hour), it is maintained for 7 hours. To Cancel the Sleep Timer To cancel the timer, press: on the remote control. The SLEEP indicator is no longer displayed. The air conditioner operates in the mode selected last. If you select the Energy Saving mode in the Sleep Timer mode, the Sleep Timer will be cancelled and the air conditioner will start up in the Energy Saving mode. E-13 Selecting Energy Saving mode Remote Control Control Panel 1 If you wish to save energy when using your air conditioner, select the energy saving mode with the Energy Saver button. [. . . ] Air the room. Odours are permeated in the room during air conditioning Technical Specifications Design and specifications are subject to change without notice. Model AA/AB BA/BB/BC/BD/BE CA/CB/CC/CD DA EA/EB/EC Power Supply 115V~, 60Hz 220V~, 60Hz 230-208V~, 60Hz 200-220V~, 50Hz 220-240V~, 50Hz E-18 Installation (for 60Hz) ENGLISH 1 Electrical Requirements For personal safety: This appliance must be properly grounded. Do not, under any circumstances, cut or remove the third grounding prong from the power cord. We recommend that you do not use an extension cord or an adapter plug with this appliance. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SAMSUNG AW12FADEB

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SAMSUNG AW12FADEB will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag