Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SAMSUNG AW12PKAF. We hope that this SAMSUNG AW12PKAF user guide will be useful to you.
Lastmanuals help download the user guide SAMSUNG AW12PKAF.
Detailed instructions for use are in the User's Guide.
[. . . ] USER'S MANUAL
AW12PK Series AW18PK Series AW24PK Series
Window-type Room Air Conditioner (Cooling)
E S DB98-31011A(2)
Register your product at www. samsung. com/global/register
Safety Precautions
The following safety precautions must be taken when using your air conditioner.
WARNING
DURING OPERATION
u
Risk of electric shock. · Disconnect all remote electric power supplies before servicing, installing or cleaning. · This must be done by the manufacturer or its service agent or a similar qualified person in order to avoid a hazard.
Users of this product are cautioned not to attempt repair of this product at their own discretion. Instead, they are requested to directly contact a designated service center or the outlet at which the product was purchased. [. . . ] Otherwise, push the ventilation lever to the left and the closed position ( Result: ). The air simply circulates inside the room.
Remote Control
If necessary, press the Result: (On/Off) button.
Control Panel
The air conditioner starts up in the Cool mode. The unit beeps twice.
3
If the FAN indicator is not lit up on the unit: Press the or Press the Result: button on the unit one or more times until the FAN / button. indicator lights up The unit beeps each time you press the The air conditioner starts up in Fan mode. When the air conditioner is in the Fan mode, the temperature is not dis played; in this case, you do not need to set the temperature. button on the remote control
4
To set the fan speed to. . . Press the or Press the button on the unit one or more times until the desired fen speed(F, F, or F3) is displayed. : Low Speed : Med Speed : High speed , or button on the remote control as desired.
5
To control the direction of the air flow, refer to page .
E-9
Removing Excess Humidity
If the atmosphere in your room is very humid or damp, you can remove excess humidity without lowering the room temperature too much. Upwards.
Adjust the air flow blades to the desired position, by pushing them upwards or downwards. If you orient the air flow blades downwards and the unit operates in Cool mode for a long period of time, dew may: From on the surface of the blades Drip from the blades
E-
Setting the On Timer
Remote Control
Control Panel
The On Timer enables you to switch on the air conditioner automatically after a given period time. You can set the period of time from 1 hour to 24 hours. You can select the On Timer only when the air conditioner is off.
Check that the air conditioner has been switched off; if necessary, press the (On/Off) button.
Set the operating time by pressing: on the remote control. Possible time is between hour and 4 hours inclusive. Result: The remaining time is displayed and decreased by hour automatically to indicate the remaining time. The air conditioner switches on automatically when the operating time reaches zero.
You can change the fan speed and others after setting the On Timer.
To Cancel the On Timer
To cancel the On Timer, press: " or (On/Off) button on the remote control or unit. on the remote control or " is displayed. on the unit one or more times until
E-
Setting the Off Timer
The Off Timer enables you to switch off the air conditioner automatically after a given period of time. You can set the period of time from 1 hour to 24 hours. You can select the Off Timer only when the air conditioner is on.
Check that the air conditioner has been switched on; if necessary, press the (On/Off) button.
Remote Control
Control Panel
Set the operating time by pressing: on the remote control. Possible time is between hour and 4 hours inclusive. Result: The remaining time is displayed and decreased by hour automatically to indicate the remaining time. The air conditioner switches off automatically when the operating time reaches zero.
You can change the fan speed and air flow direction and others after setting the Off Timer.
To Cancel the Off Timer
To cancel the Off Timer, press: " or (On/Off) button on the remote control or unit. on the remote control or " is displayed. on the unit one or more times until
E-3
Selecting Good Sleep Mode
The Good Sleep mode can be used when you are cooling your room to switch the air conditioner off automatically after 8 hours.
Remote Control
Control Panel
The Good Sleep function can be set whether the air conditioner is switched on or off, and this function can be selected for any mode.
Press the or Press the Result: button on the remote control button on the unit . [. . . ] The air flow direction does not change when you press the or on the unit button Check that the timer has been programmed correctly; see page ~3. Odour is permeated in the room during air conditioning Air the room. Check that the air conditioner has been switched on; if necessary, press (On/Off) button on the remote control or unit.
The timer is not correctly triggered
E-7
Technical Specifications
Design and specifications are to change without notice
Model Voltage & Frequecy 115V~, 60Hz 220V~, 60Hz 220V~, 60Hz 220V~, 60Hz 115V~, 60Hz 220V~, 60Hz 115V~, 60Hz 220V~, 60Hz 220V~, 60Hz 220V~, 60Hz 115V~, 60Hz 220V~, 60Hz Capacity Power Operating Consumption Current 1230W 1230W 1850W 2820W 1110W 1110W 1220W 1220W 1850W 2820W 1190W 1190W 11. 2A 5. 5A 8. 3A 12. 5A 10. 0A 5. 2A 11. 2A 5. 5A 8. 3A 12. 5A 10. 6A 5. 5A
AW12PKAA AW12PKBA AW18PKBA AW24PKBA AW12PKAB AW12PKBB AW12PKAC AW12PKBC AW18PKBC AW24PKBC AW12PKAF AW12PKBF
12000BTU/h 12000BTU/h 18000BTU/h 24000BTU/h 12000BTU/h 12000BTU/h 12000BTU/h 12000BTU/h 18000BTU/h 24000BTU/h 12500BTU/h 12500BTU/h
E-18
Installation (for 60Hz)
Electrical Requirements For personal safety: This appliance must be properly grounded. Do not, under any circumstances, cut or remove the third grounding prong from the power cord. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SAMSUNG AW12PKAF
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SAMSUNG AW12PKAF will begin.