Detailed instructions for use are in the User's Guide.
[. . . ] Check for: - Close the door, and run the dryer. Check for: - Display PCB key circuit short or not. Check for: - Not using regular power source frequency - Invalid power frequency sense circuit Check for: - Check PCB and Wire harness. Call customer service Call customer service Call customer service Call customer service
tE
tE3
The resistance of the thermistor for the vent blockage detection operation is very low or very high. [. . . ] If you press the down arrow button, the display mode ID decreases. Definition of Software Version Mode: Display Mode 0 : Temperature data Display Mode 1 : Average Touch Sensor data for 1 minute Display Mode 2 : Average Temperature data for 1 minute
5
Technical_information-02835D-01_EN. Indd 5
2012-03-26
2:28:50
ALIGNMENT AND ADJUSTMENTS
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. DR modem connection test
Check if the parts from the Main PBA to the DR modem are properly connected electronically. DV457* Model Only
-
If you press the “3” button in service mode, the DR wire test is performed. if the DR wire test is successful , SG is displayed. Service Mode
* If "AE3" or "AE4" error occured, press the Start button then error will be cleared. how to exit : DV455* Press Wrinkle Prevent + Temp. If no key is operated during Service Mode for 5 minutes, the machine will return to normal user mode. DV457* Tap Segment “4“ three times Tap Segment “1” two times Tap Segment “4” once On the Service Mode. If no key is operated during Service Mode for 5 minutes, the machine will return to normal user mode.
Segment 1 Segment 2 Segment 3 Segment 4
6
Technical_information-02835D-01_EN. Indd 6
2012-03-26
2:28:50
ALIGNMENT AND ADJUSTMENTS
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. TROUBLE DIAGNOSIS
As the micom dry machine is configured of the complicate structure, there might be the service call. Below information is prepared for exact trouble diagnosis and suitable repair guide. Caution for the Repair and Replacement
Please follow below instruction for the trouble diagnosis and parts replacement. 1) As some electronic components are damaged by the charged static electricity from the resin part of dryer or the human body, prepare the human body earth or remove the potential differ ence of the human body and dryer by contacting the power supply plug when the work contacting to PCB is executed. B assembly is designed for no trouble, do not replace the P. B assembly by the wrong diagnosis and follow the procedure of the trouble diagnosis when the micom is not operated normally. 7
Technical_information-02835D-01_EN. [. . . ] Indd 10
2012-03-26
2:28:51
TROUBLE SHOOTING
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. 23Ω @ 25 °C 77
GAS MODEL
Radiant Sensor(10RS) Resistance value < 1 Ω If resistance is infinite, replace Radiant sensor Gas Valve(25M01A) Valve 1-2 : Resistance value about 1365 Ω Valve 1-3 : Resistance value about 560 Ω Valve 4-5 : Resistance value about 1325 Ω If resistance is infinity, replace Valve
Igniter(101D) Resistance value 40~400 Ω If resistance is infinite, replace Igniter
Thermostat (60T21 Hi-Limit)230F-50F Resistance value < 1 Ω If resistance is infinity, replace Thermostat
11
Technical_information-02835D-01_EN. Indd 11
2012-03-26
2:28:51
TROUBLE SHOOTING
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. Connect the other wires to the outer terminal block screws. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SAMSUNG DV457EVGSGR
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SAMSUNG DV457EVGSGR will begin.