User manual SAMSUNG MH050FXEA2C

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SAMSUNG MH050FXEA2C. We hope that this SAMSUNG MH050FXEA2C user guide will be useful to you.

Lastmanuals help download the user guide SAMSUNG MH050FXEA2C.


Mode d'emploi SAMSUNG MH050FXEA2C
Download
Manual abstract: user guide SAMSUNG MH050FXEA2C

Detailed instructions for use are in the User's Guide.

[. . . ] Safety Precautions (Carefully follow the precautions listed below because they are essential to guarantee the safety of the equipment. ) WARNING · Always disconnect the air conditioner from the power supply before servicing it or accessing its internal components. · Verify that installation and testing operations are performed by qualified personnel. · Verify that the air conditioner is not installed in an easily accessible area. GENERAL INFORMATION Carefully read the content of this manual before installing the air conditioner and store the manual in a safe place in order to be able to use it as reference after installation. conditioner is sold or transferred. For maximum safety, installers should always carefully read the following warnings. [. . . ] Fix the case with bolts to the side of the control box referring to the figure on the left side. In case of FJM outdoor unit, there is not enough space to fix all parts of transmitter. So you may use transmitter main PCB. Attach the transmitter main PCB to the case, then connect F1/F2 lines, R1/R2 lines which are upper controller communication cables and DC 12V power cables to the interface module referring to the figure on page 21. (Upper controller power should be off. ) You must check the position of dip switch on the transmitter main PCB and the main PCB of all of the indoor units. Assemble a cover of the outdoor unit and turn the power on. If you install a transmitter to the outdoor unit, every indoor unit which is connected to the outdoor unit can be controlled simultaneously. Each outdoor unit connected to the same centralized controller has its own transmitter. 3 Fix the case with bolts (Control Box in the outdoor unit) 4 MH060FXA3B/MH070FXA4B / MH080FXA4B Terminal side 5 6 7 Transmitter 8 7seg. LED Display side Fix the case with bolts (Control Box in the outdoor unit) E-20 09'FJM_OUTDOOR_28896A_IM_E_11. 23. 09. indd 20 2009-11-24 9:20:03 INSTALLING THE OUTDOOR UNIT DC 12V (Blue) (Blue) DC 12V supply DC 12V (Blue) CN01(Blue) Transmitter MAIN PCB MH050FXA2B/MH050FXA2C MH040FXA2B/MH040FXA2C /MH060FXA3B/MH070FXA4B /MH18VF1X/MH19VF1X Outdoor unit PCB /MH080FXA4B Terminal Block in the outdoor unit Terminal Block in the outdoor unit Terminal Block in the outdoor unit MH070FXA4B/MH080FXA4B MH060FXA3B MH040FXA2B/MH040FXA2C/ MH050FXA2B/MH050FXA2C/ MH18VF1X/MH19VF1X Check the dip switch postion on transmitter main PCB as the picture above, "turn ON" K1 K2 K3 K4 Change DIPswitch-K2 in all indoor units PCB (K2 : ON OFF) E-21 09'FJM_OUTDOOR_28896A_IM_E_11. 23. 09. indd 21 2009-11-24 9:20:12 ENGLISH INSTALLING THE OUTDOOR UNIT Checking Correct Earthing If the power distribution circuit does not have an earth or the earth does not comply with specifications, an earthing electrode must be installed. The corresponding accessories are not supplied with the air conditioner. Carbon plastic Steel core To earthing screw 1 2 Select an earthing electrode that complies with the specifications given in the illustration opposite. Determine a suitable location for the earthing electrode: In damp hard soil rather than loose sandy or gravel soil that has a higher earthing resistance Away from underground structures or facilities, such as gas pipes, water pipes, telephone lines and underground cables At least two meters away from a lightening conductor earthing electrode and its cable. The earthing wire for the telephone line cannot be used to earth the air conditioner. Dig a hole of the size indicated in the illustration opposite, drive the earthing electrode into position and cover the top of the electrode with the excavated soil. Install a green/yellow insulated earthing wire (Ø1. 6 mm, section 2 mm2 or greater): If the earthing wire is too short, connect an extension lead, soldering the connec tion and wrapping it with insulating tape (do not bury the soldered connection) Secure the earthing wire in position with staples If the earthing electrode is installed in an area of heavy traffic, its wire must be connected securely. Carefully check the installation, by measuring the earthing resistance with an earthing resistance tester. If the resistance is above the required level(Example:100), drive the earthing electrode deeper into the ground or increase the number of earthing electrodes. Connect the earthing wire to the earthing screw on the air conditioner. PVC-insulated green/ yellow wire, 2mm2 x 3. 5 m 50 cm 30 cm 3 4 5 6 Fixing the Unit in Position `X' mm `Y' mm The outdoor unit must be installed on a rigid and stable base to avoid any increase in the noise level and vibration, particularly if the outdoor unit is to be installed close to a neighbour. If it is to be installed in a location exposed to strong winds or at a height, the unit must be fixed to an appropriate support (wall or ground). Rubber leg 1 Y 319 Position the outdoor unit so that the air flow is directed towards the outside, as indicated by the arrows on the top of the unit. Attach the outdoor unit to the appropriate support using anchor bolts. If the outdoor unit is exposed to strong winds, install shield plates around the outdoor unit, so that the fan can operate correctly. Certainly fix up its rubber leg in order to prevent its vibration and noise. Model MH040FXA2B MH040FXA2C MH18VF1X MH19VF1X MH050FXA2B MH050FXA2C MH060FXA3B MH070FXA4B MH080FXA4B X 543 2 3 660 350 Designed to cut off residual vibration from outdoor unit to rack. (not supplied with product) OUTDOOR UNIT INSTALLED ON THE WALL BY RACK - Ensure the wall will be able to suspend the weight of rack and outdoor unit; - Install the rack close to the colum as much as possible; - Install proper grommet in order to reduce noise and residual vibration transferred by outoor unit towards wall. Soft rubber designed to cut off vibration from rack to wall. (not supplied with product) E-22 09'FJM_OUTDOOR_28896A_IM_E_11. 23. 09. indd 22 2009-11-24 9:20:16 COMPLETING THE INSTALLATION Connecting Up and Purging the Circuit ENGLISH Indoor A-unit Indoor B-unit WARNING When installing, make sure there is no leakage. [. . . ] Contact the authorized service technician or dealer for setting and changing the "Ampere Limit Switch". Before changing the "Ampere Limit Switch", turn off the main power of the system. Ampere MH040FXA2B MH040FXA2C MH18VF1X MH19VF1X K1 DIS01 DIS02 Switch Selection Switch 3 4 MH070FXA4B MH050FXA2B MH060FXA3B MH050FXA2C MH080FXA4B 13. 5A (Default) 14. 5A (Default) 16. 6A (Default) SW02 SW01 Switch Indoor unit address 9. 0A (Default) ON (OFF) ON 8. 5A 11. 0A 13. 0A 14. 0A (OFF) ON OFF K2 K3 K4 8. 0A 9. 0A 10. 0A 11. 0A (OFF) OFF ON View data display Outdoor PCB Display 7. 0A 8. 0A 8. 0A 10. 0A (OFF) OFF OFF E-30 09'FJM_OUTDOOR_28896A_IM_E_11. 23. 09. indd 30 2009-11-24 9:20:50 COMPLETING THE INSTALLATION Pipe Checking Operation (Auto Addressing Mode) ENGLISH Switch the system on and wait for code " " to appear on the display of the external unit (this requires approximately 60 seconds **). "displays, press once the red button (K1) shown on As soon as code " the figure on the side of the page: Red Button K1 WARNING !! If the quantity of indoor units connected is lower than maximum connectable to outdoor unit, the rotary switch SW01 has to be positioned, in order to select a number equal to indoor units' quantity you connected. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SAMSUNG MH050FXEA2C

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SAMSUNG MH050FXEA2C will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag