[. . . ] USER'S MANUAL
Multi Function Wired Remote Controller
MWR-WE00
System Air Conditioner
E S F I P D G Ne Po Hu R A DB98-30794A(1)
RUSSIAN
MAGYAR
POLSKI
NEDERLANDS
EHNIKA
DEUTSCH
PORTUGUÊS
ITALIANO
FRANÇAIS
ESPAÑOL
ENGLISH
Safety Precautions
· Before using the multi function wired remote controller, read carefully these instructions. · After reading the instructions, keep this user's manual in a handy and safe place. If a user is changed, you must hand over the manuals. · Never attempt to install the air conditioning system or to move the multi function wired remote controller by yourself.
WARNING
o not attempt to install or repair this multi function D
wired remote controller by yourself.
his remote controller contains no user-serviceable parts. [. . . ] (Defrost indicator) - Defrost indicator will be on while your outdoor unit defrosts the frost formed during heating operation. After defrosting is completed, the indicator will be off. (Air will not come out of the indoor unit while defrosting. ) If you stop running the air conditioner after heating operation, the air will come out for a while to radiate heat. Press the button again to stop the blade from swinging and set the blade to the desired position.
Note
The air swing direction cannot be set on duct type indoor units. will be displayed when the button is pressed.
E-13
ENGLISH
Checking the Room Temperature
You can check the current room temperature.
1
Press the Result: Note
button to check the room temperature. T he room temperature will be displayed for 3 seconds and return to set temperature display. The room temperature may be slightly different depending on the installation location of the remote controller.
Locking the Multi Function Wired Remote Controller
Lock the multi function wired remote controller to prevent it from children and changing the settings unwillingly.
1
Press the Result:
button for 3 seconds. will be displayed and the multi function wired remote controller is locked. When the multi function wired remote controller is locked, you cannot control the air conditioner by the multi function wired remote controller. button for 3 seconds again to cancel
Note
E-14
Operating the ERV
Select ERV function to ventilate the room.
1
Press the Result:
button to start ERV ventilating system. T he fan speed will be displayed as High
2
Press the
button to select the fan speed.
You can adjust the fan speed by pressing the button. The fan speed changes in order of High Turbo Med To stop the ERV, press the fan speed is Med
button again when the
Note
If you press the button when ERV unit is connected to the multi function wired remote controller, you can turn on/off both of ERV and the air conditioner at the same time or turn on/off the air conditioner only. The default setting is turning on/off both of them. (Refer to the installation manual. ) The button operates when more than 1 ERV unit is connected to the multi function wired remote controller. will be displayed when you press the If not, button. ERV operates in heat exchange mode only.
E-15
ENGLISH
Using the E. Saver Function
Select E. Saver function to save electricity.
1
Press the Result: Note
button. T he air conditioner will operate in E. Saver mode. In fan mode, E. Saver is displayed but the E. Saver function is not operated.
Note
The button operates only when 1 indoor unit and 1 ERV unit is connected to the multi function wired remote controller. If ERV unit is not connected or more than 2 ERV units will be displayed when you are connected, control it. When E. Saver function in operation, the indoor unit and ERV unit may operate automatically. [. . . ] button to cancel the setting.
4
Press the settings. Result: Note
5
Press the Result:
Note
E-24
The lower limit can not be same or higher than upper limit. Even though you set the lower temperature limit to 16°C(61°F), lower temperature will be set to 18°C(65°F) in all the modes except in heating mode. When you set the lower temperature limit to 18°C(65°F), it will be applied under all the operation modes. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SAMSUNG MWR-WE00
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.