[. . . ] INV HSP MA DUCT_DB98-33882A. indd 1
2011-5-31 18:54:08
Featuresofyournewairconditioner
· CoolSummerOffer
On those hot sweltering summer days and long restless nights, there is no better escape from the heat than the cool comforts of home. Your new air conditioner brings an end to exhausting hot summer days and lets you rest. This summer, beat the heat with your own air conditioner.
· CostEfficientSystem
Your new air conditioner not only provides maximum cooling power in the summer, but can also be an efficient heating method in the winter with the advanced "Heat pump" system. This technology is up to 300% more efficient than electrical heating, so you can further reduce its running cost. [. . . ] Do not place containers with liquids or other objects on the unit. All the materials used for the manufacture and packaging of the air conditioner are recyclable. The packing material and exhaust batteries of the remote control(optional) must be disposed of in accordance with current laws. The air conditioner contains a refrigerant that has to be disposed of as special waste. At the end of its life cycle, the air conditioner must be disposed of in authorized centers or returned to the retailer so that it can be disposed of correctly and safely.
installinG the unit
IMPORTANT: When installing the unit, always remember to connect first the refrigerant tubes, then the electrical lines. Always disassemble the electric lines before the refrigerant tubes. Upon receipt, inspect the product to verify that it has not been damaged during transport. If the product appears damaged, DO NOT INSTALL it and immediately report the damage to the carrier or retailer (if the installer or the authorized technician has collected the material from the retailer. ) After completing the installation, always carry out a functional test and provide the instructions on how to operate the air conditioner to the user. Do not use the air conditioner in environments with hazardous substances or close to equipment that release free flames to avoid the occurrence of fires, explosions or injuries. The air conditioner should be used only for the applications for which it has been designed: the indoor unit is not suitable to be installed in areas used for laundry.
14
INV HSP MA DUCT_DB98-33882A. indd 14 2011-5-31 18:54:24
Our units must be installed in compliance with the spaces indicated in the installation manual to ensure either accessibility from both sides or ability to perform routine maintenance and repairs. The units' components must be accessible and that can be disassembled in conditions of complete safety either for people or things. For this reason, where it is not observed as indicated into the Installation Manual, the cost necessary to reach and repair the unit (in safety, as required by current regulations in force) with slings, trucks, scaffolding or any other means of elevation won't be considered in-warranty and charged to end user.
Power suPPly line, fuse or circuit breaker
Always make sure that the power supply is compliant with current safety standards. Always install the air conditioner in compliance with current local safety standards. Always verify that a suitable grounding connection is available. Verify that the voltage and frequency of the power supply comply with the specifications and that the installed power is sufficient to ensure the operation of any other domestic appliance connected to the same electric lines. Always verify that the cut-off and protection switches are suitably dimensioned. Verify that the air conditioner is connected to the power supply in accordance with the instructions provided in the wiring diagram included in the manual. Always verify that electric connections (cable entry, section of leads, protections. . . ) are compliant with the electric specifications and with the instructions provided in the wiring scheme. Always verify that all connections comply with the standards applicable to the installation of air conditioners.
CAUTION
Make sure that you earth the cables. - Do not connect the earth wire to the gas pipe, water pipe, lighting rod or telephone wire. If earthing is not complete, electric shock or fire may occur. - If the circuit breaker is not installed, electric shock or fire may occur. [. . . ] The total option codes are 24digits. you can set six digits at a time and it is distinguished by page number(0, 1, 2, 3).
SGE2 2 SEG8 Drain pump SEG14 External control SEG20 Individual control of a remote controller SGE3 RESERVED SEG9 RESERVED SEG15 External control output SEG21 Heating setting compensation SGE4 Exterior temperature sensor SEG10 RESERVED SEG16 S-Plasma ion SGE5 Central control SEG11 RESERVED SEG17 Buzzer SGE6 RESERVED SEG12 Master / Slave SEG18 Number of hours using filter -
SGE1 0 SEG7 1 SEG13 2 SEG19 3
30
INV HSP MA DUCT_DB98-33882A. indd 30 2011-5-31 18:54:46
OptionNo. :02XXXX-1XXXXX-2XXXXX-3XXXXX
Option Explanation SEG1 PAGE SEG2 MODE RESERVED SEG3 SEG4 Use of external temperature sensor SEG5 Use of central control Details RESERVED SEG6
Indication and Details Option Explanation
Indication Details Indication Details 0 2
Indication Details Indication 0 1 Disuse Use SEG10 0 1
SEG7 SEG8 SEG9 PAGE Use of drain pump Indication Details Indication Details 0 Disuse RESERVED RESERVED RESERVED Indication 1 Use and Details 1 Use + 2 3minute delay Option SEG13 SEG14 SEG15 SEG16 SEG17 Use of external Setting the output of S-Plasma ion Explanation PAGE Buzzer control control external control Indication Details Indication Details Indication Details Indication Details Indication Details Thermo Use of Disuse 0 0 0 Disuse 0 on buzzer Indication ON/OFF and Details 2 1 Non Control Operation 1 1 Use 1 use of on OFF buzzer 2 Control Option SEG19 SEG20 SEG21 Individual control Heating setting Explanation PAGE of a remote compensation controller Indication and Details Indication Details Indication 0 or 1 2 3 3 4 Details Indication Indoor 1 0 Indoor 2 1 Indoor 3 2 Indoor 4 Details Disuse 2°C 5°C -
Disuse Use SEG11
SEG12 Master / Slave Indication Details 0 slave 1 master -
SEG18 Number of hours using filter Indication Details 2 6 1000 Hour 2000 Hour -
4 Press the
buttons and the Indoor unit DIP option code. button.
button to set the
5 Press the
Wired remote controller sends data to an indoor unit.
6 Press the
button to exit.
You will move to the menu selection display.
· Press the button anytime during setup to exit without setting. · Setting an indoor unit DIP option code is available only with a master wired remote controller. · Setting an indoor unit DIP option code is available when there is one on one connection between a wired remote controller and an indoor unit. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SAMSUNG NS100HHXEH
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.